138 research outputs found

    Exercise builds the scaffold of life: muscle extracellular matrix biomarker responses to physical activity, inactivity, and aging

    Get PDF
    Skeletal muscle extracellular matrix (ECM) is critical for muscle force production and the regulation of important physiological processes during growth, regeneration, and remodelling. ECM remodelling is a tightly orchestrated process, sensitive to multi-directional tensile and compressive stresses and damaging stimuli, and its assessment can convey important information on rehabilitation effectiveness, injury, and disease. Despite its profound importance, ECM biomarkers are underused in studies examining the effects of exercise, disuse, or aging on muscle function, growth, and structure. This review examines patterns of short- and long-term changes in the synthesis and concentrations of ECM markers in biofluids and tissues, which may be useful for describing the time course of ECM remodelling following physical activity and disuse. Forces imposed on the ECM during physical activity critically affect cell signalling while disuse causes non-optimal adaptations, including connective tissue proliferation. The goal of this review is to inform researchers, and rehabilitation, medical, and exercise practitioners better about the role of ECM biomarkers in research and clinical environments to accelerate the development of targeted physical activity treatments, improve ECM status assessment, and enhance function in aging, injury, and disease

    Improving the resolution of retinal OCT with deep learning

    Get PDF
    In medical imaging, high-resolution can be crucial for identifying pathologies and subtle changes in tissue structure. However, in many scenarios, achieving high image resolution can be limited by physics or available technology. In this paper, we aim to develop an automatic and fast approach to increasing the resolution of Optical Coherence Tomography (OCT) images using the data available, without any additional information or repeated scans. We adapt a fully connected deep learning network for the super-resolution task, allowing multi-scale similarity to be considered, and create a training and testing set of more than 40,000 sample patches from retinal OCT data. Testing our model, we achieve an impressive root mean squared error of 5.847 and peak signal-to-noise ratio (PSNR) of 33.28 dB averaged over 8282 samples. This represents a mean improvement in PSNR of 3.2 dB over nearest neighbour and 1.4 dB over bilinear interpolation. The results achieved so far improve over commonly used fast techniques for increasing resolution and are very encouraging for further development towards fast OCT super-resolution. The ability to increase quickly the resolution of OCT as well as other medical images has the potential to impact significantly on medical imaging at point of care, allowing significant small details to be revealed efficiently and accurately for inspection by clinicians and graders and facilitating earlier and more accurate diagnosis of disease

    Eccentric Exercise Facilitates Mesenchymal Stem Cell Appearance in Skeletal Muscle

    Get PDF
    Eccentric, or lengthening, contractions result in injury and subsequently stimulate the activation and proliferation of satellite stem cells which are important for skeletal muscle regeneration. The discovery of alternative myogenic progenitors in skeletal muscle raises the question as to whether stem cells other than satellite cells accumulate in muscle in response to exercise and contribute to post-exercise repair and/or growth. In this study, stem cell antigen-1 (Sca-1) positive, non-hematopoetic (CD45-) cells were evaluated in wild type (WT) and α7 integrin transgenic (α7Tg) mouse muscle, which is resistant to injury yet liable to strain, 24 hr following a single bout of eccentric exercise. Sca-1+CD45− stem cells were increased 2-fold in WT muscle post-exercise. The α7 integrin regulated the presence of Sca-1+ cells, with expansion occurring in α7Tg muscle and minimal cells present in muscle lacking the α7 integrin. Sca-1+CD45− cells isolated from α7Tg muscle following exercise were characterized as mesenchymal-like stem cells (mMSCs), predominantly pericytes. In vitro multiaxial strain upregulated mMSC stem cells markers in the presence of laminin, but not gelatin, identifying a potential mechanistic basis for the accumulation of these cells in muscle following exercise. Transplantation of DiI-labeled mMSCs into WT muscle increased Pax7+ cells and facilitated formation of eMHC+DiI− fibers. This study provides the first demonstration that mMSCs rapidly appear in skeletal muscle in an α7 integrin dependent manner post-exercise, revealing an early event that may be necessary for effective repair and/or growth following exercise. The results from this study also support a role for the α7 integrin and/or mMSCs in molecular- and cellular-based therapeutic strategies that can effectively combat disuse muscle atrophy

    Equation of state and phonon frequency calculations of diamond at high pressures

    Full text link
    The pressure-volume relationship and the zone-center optical phonon frequency of cubic diamond at pressures up to 600 GPa have been calculated based on Density Functional Theory within the Local Density Approximation and the Generalized Gradient Approximation. Three different approaches, viz. a pseudopotential method applied in the basis of plane waves, an all-electron method relying on Augmented Plane Waves plus Local Orbitals, and an intermediate approach implemented in the basis of Projector Augmented Waves have been used. All these methods and approximations yield consistent results for the pressure derivative of the bulk modulus and the volume dependence of the mode Grueneisen parameter of diamond. The results are at variance with recent precise measurements up to 140 GPa. Possible implications for the experimental pressure determination based on the ruby luminescence method are discussed.Comment: 10 pages, 6 figure

    Optical coherence tomography—current technology and applications in clinical and biomedical research

    Get PDF

    Refractive index tomography of turbid media by bifocal optical coherence refractometry

    Full text link
    We demonstrate tomographic imaging of the refractive index of turbid media using bifocal optical coherence refractometry (BOCR). The technique, which is a variant of optical coherence tomography, is based on the measurement of the optical pathlength difference between two foci simultaneously present in a medium of interest. We describe a new method to axially shift the bifocal optical pathlength that avoids the need to physically relocate the objective lens or the sample during an axial scan, and present an experimental realization based on an adaptive liquid-crystal lens. We present experimental results, including video clips, which demonstrate refractive index tomography of a range of turbid liquid phantoms, as well as of human skin in vivo.<br /

    Optics and Quantum Electronics

    Get PDF
    Contains table of contents for Section 3, reports on twenty-one research projects and a list of publications and meeting papers.Joint Services Electronics Program Contract DAAL03-92-C-0001U.S. Air Force - Office of Scientific Research Contract F49620-91-C-0091Charles S. Draper Laboratories Contract DL-H-441692MIT Lincoln LaboratoryNational Science Foundation Grant ECS 90-12787Fujitsu LaboratoriesU.S. Navy - Office of Naval Research Grant N00014-92-J-1302National Center for Integrated Photonic TechnologyNational Science Foundation Grant ECS 85-52701U.S. Navy - Office of Naval Research (MFEL) Grant N00014-91-C-0084U.S. Navy - Office of Naval Research (MFEL) Grant N00014-91-J-1956National Institutes of Health Grant R01-GM35459-08U.S. Air Force - Office of Scientific Research Grant F49620-93-1-0301MIT Lincoln Laboratory Contract BX-5098Electric Power Research Institute Contract RP3170-2

    Optics and Quantum Electronics

    Get PDF
    Contains table of contents for Section 3 and reports on twenty research projects.Charles S. Draper Laboratories Contract DL-H-467138Joint Services Electronics Program Contract DAAL03-92-C-0001Joint Services Electronics Program Grant DAAH04-95-1-0038U.S. Air Force - Office of Scientific Research Contract F49620-91-C-0091MIT Lincoln LaboratoryNational Science Foundation Grant ECS 90-12787Fujitsu LaboratoriesNational Center for Integrated PhotonicsHoneywell Technology CenterU.S. Navy - Office of Naval Research (MFEL) Contract N00014-94-1-0717U.S. Navy - Office of Naval Research (MFEL) Grant N00014-91-J-1956National Institutes of Health Grant NIH-5-R01-GM35459-09U.S. Air Force - Office of Scientific Research Grant F49620-93-1-0301MIT Lincoln Laboratory Contract BX-5098Electric Power Research Institute Contract RP3170-25ENEC
    • …
    corecore