4 research outputs found

    Simultaneous determination of candesartan and hydrochlorothiazide in human plasma by LC-MS/MS

    Get PDF
    A simple, sensitive, rapid and highly efficient LC-MS/MS method was developed for the determination of Candesartan and Hydrochlorothiazide simultaneously in human plasma. The method employed Zorbax eclipse C18 (150 X 4.6 mm, 5µ) column using acetate buffer: acetonitrile (25:75%, v/v) as the mobile phase. The mobile phase flow rate is 1 mL/min which was delivered into the mass spectrometer electron spray ionization chamber. The Liquid/liquid extraction procedure was used in the method for the extraction of analytes. The chromatograph was attached to a negative ion mode tandem mass spectrometer and the method was validated for all the parameters as per the guidelines of US-FDA. The ions were detected in multiple reaction monitoring mode and the transitions are m/z 439.00®309.10 and 295.80®268.80 for candesartan and hydrochlorothiazide respectively. Isotopic standards were used as internal standards for effective recovery of the analytes. The drugs were analyzed over a calibration range of 1.027-302.047 ng/mL for candesartan and 1.044-306.945 ng/mL for hydrochlorothiazide respectively with regression coefficient greater than 0.99. The mean extraction recoveries are 96.95±5.61 and 100.55±4.82 for candesartan and hydrochlorothiazide respectively. The precision and accuracy values for all the studies were within the range of ≤15% and 85-115%. The performed stability studies indicate that the developed method is stable in plasma for 15 h at room temperature (bench top); 52 h (in injector); for 112 days at -70 ºC for long term stability; five successive freeze and thaw cycles. The developed method could be successfully employed for the determination of selected drugs in biological samples

    DEVELOPMENT AND VALIDATION OF STABILITY INDICATING REVERSE PHASE HIGH‑PERFORMANCE LIQUID CHROMATOGRAPHY METHOD FOR SIMULTANEOUS ESTIMATION OF ATENOLOL, HYDROCHLOROTHIAZIDE AND LOSARTAN IN BULK AND PHARMACEUTICAL DOSAGE FORM

    Get PDF
    ABSTRACTObjective: The objective of present work was to develop and validate a simple, fast, precise, selective and accurate reverse phase high-performanceliquid chromatography method for the simultaneous determination atenolol (ATN), hydrochlorothiazide (HCTZ) and losartan (LOS) in apharmaceutical dosage form.Methods: The separation of these three drugs was achieved on an SHISHEDO C, 250 mm × 4.6 mm, 5 µ size column with a mobile phase consistingof acetonitrile and 0.5% orthophosphoric acid (30:70 v/v) at a flow rate of 1 ml/minute and UV detection at 224 nm.18Results: The retention times were observed to be 2.242, 3.963 and 6.733 minutes for ATN, HCTZ and LOS, respectively. Linearity was found to be4-12 μg/ml, 4-12 μg/ml, 1-3 μg/ml for ATN, HCTZ and LOS, respectively. The method was statistically validated for linearity, recovery, the limit ofdetection (LOD), limit of quantification (LOQ), accuracy and precision. The stress testing of the drugs individually and their mixture is carried outunder acidic, alkaline, oxidation, photo-stability and thermal degradation conditions and its degradation products is well-resolved from the analytepeaks.Conclusion: This method was successfully validated for accuracy, precision, and linearity, LOD and LOQ.Keywords: Atenolol, Hydrochlorothiazide, Losartan, Reverse phase high-performance liquid chromatography

    Simultaneous determination of candesartan and hydrochlorothiazide in human plasma by LC-MS/MS

    No full text
    Abstract A simple, sensitive, rapid and highly efficient LC-MS/MS method was developed for the determination of Candesartan and Hydrochlorothiazide simultaneously in human plasma. The method employed Zorbax eclipse C18 (150 X 4.6 mm, 5µ) column using acetate buffer: acetonitrile (25:75%, v/v) as the mobile phase. The mobile phase flow rate is 1 mL/min which was delivered into the mass spectrometer electron spray ionization chamber. The Liquid/liquid extraction procedure was used in the method for the extraction of analytes. The chromatograph was attached to a negative ion mode tandem mass spectrometer and the method was validated for all the parameters as per the guidelines of US-FDA. The ions were detected in multiple reaction monitoring mode and the transitions are m/z 439.00®309.10 and 295.80®268.80 for candesartan and hydrochlorothiazide respectively. Isotopic standards were used as internal standards for effective recovery of the analytes. The drugs were analyzed over a calibration range of 1.027-302.047 ng/mL for candesartan and 1.044-306.945 ng/mL for hydrochlorothiazide respectively with regression coefficient greater than 0.99. The mean extraction recoveries are 96.95±5.61 and 100.55±4.82 for candesartan and hydrochlorothiazide respectively. The precision and accuracy values for all the studies were within the range of ≤15% and 85-115%. The performed stability studies indicate that the developed method is stable in plasma for 15 h at room temperature (bench top); 52 h (in injector); for 112 days at -70 ºC for long term stability; five successive freeze and thaw cycles. The developed method could be successfully employed for the determination of selected drugs in biological samples

    Simultaneous determination of candesartan and hydrochlorothiazide in human plasma by LC-MS/MS

    Get PDF
    <div><p>Abstract A simple, sensitive, rapid and highly efficient LC-MS/MS method was developed for the determination of Candesartan and Hydrochlorothiazide simultaneously in human plasma. The method employed Zorbax eclipse C18 (150 X 4.6 mm, 5µ) column using acetate buffer: acetonitrile (25:75%, v/v) as the mobile phase. The mobile phase flow rate is 1 mL/min which was delivered into the mass spectrometer electron spray ionization chamber. The Liquid/liquid extraction procedure was used in the method for the extraction of analytes. The chromatograph was attached to a negative ion mode tandem mass spectrometer and the method was validated for all the parameters as per the guidelines of US-FDA. The ions were detected in multiple reaction monitoring mode and the transitions are m/z 439.00®309.10 and 295.80®268.80 for candesartan and hydrochlorothiazide respectively. Isotopic standards were used as internal standards for effective recovery of the analytes. The drugs were analyzed over a calibration range of 1.027-302.047 ng/mL for candesartan and 1.044-306.945 ng/mL for hydrochlorothiazide respectively with regression coefficient greater than 0.99. The mean extraction recoveries are 96.95±5.61 and 100.55±4.82 for candesartan and hydrochlorothiazide respectively. The precision and accuracy values for all the studies were within the range of ≤15% and 85-115%. The performed stability studies indicate that the developed method is stable in plasma for 15 h at room temperature (bench top); 52 h (in injector); for 112 days at -70 ºC for long term stability; five successive freeze and thaw cycles. The developed method could be successfully employed for the determination of selected drugs in biological samples.</p></div