33 research outputs found

    Hypoxia inducible factor 1α gene (HIF-1α) splice variants: potential prognostic biomarkers in breast cancer

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Hypoxia-inducible factor 1 (HIF-1) is a master transcriptional regulator of genes regulating oxygen homeostasis. The HIF-1 protein is composed of two HIF-1α and HIF-1β/aryl hydrocarbon receptor nuclear translocator (ARNT) subunits. The prognostic relevance of HIF-1α protein overexpression has been shown in breast cancer. The impact of HIF-1α alternative splice variant expression on breast cancer prognosis in terms of metastasis risk is not well known.</p> <p>Methods</p> <p>Using real-time quantitative reverse transcription PCR assays, we measured mRNA concentrations of total <it>HIF-1α </it>and 4 variants in breast tissue specimens in a series of 29 normal tissues or benign lesions (normal/benign) and 53 primary carcinomas. In breast cancers <it>HIF-1α </it>splice variant levels were compared to clinicopathological parameters including tumour microvessel density and metastasis-free survival.</p> <p>Results</p> <p><it>HIF-1α </it>isoforms containing a three base pairs TAG insertion between exon 1 and exon 2 (designated <it>HIF-1α</it><sup><it>TAG</it></sup>) and <it>HIF-1α</it><sup><it>736 </it></sup>mRNAs were found expressed at higher levels in oestrogen receptor (OR)-negative carcinomas compared to normal/benign tissues (<it>P </it>= 0.009 and <it>P </it>= 0.004 respectively). In breast carcinoma specimens, lymph node status was significantly associated with <it>HIF-1α</it><sup><it>TAG </it></sup>mRNA levels (<it>P </it>= 0.037). Significant statistical association was found between tumour grade and <it>HIF-1α</it><sup><it>TAG </it></sup>(<it>P </it>= 0.048), and total <it>HIF-1α </it>(<it>P </it>= 0.048) mRNA levels. <it>HIF-1α</it><sup><it>TAG </it></sup>mRNA levels were also inversely correlated with both oestrogen and progesterone receptor status (<it>P </it>= 0.005 and <it>P </it>= 0.033 respectively). Univariate analysis showed that high <it>HIF-1α</it><sup><it>TAG </it></sup>mRNA levels correlated with shortened metastasis free survival (<it>P </it>= 0.01).</p> <p>Conclusions</p> <p>Our results show for the first time that mRNA expression of a <it>HIF-1α</it><sup><it>TAG </it></sup>splice variant reflects a stage of breast cancer progression and is associated with a worse prognosis.</p> <p>See commentary: <url>http://www.biomedcentral.com/1741-7015/8/45</url></p

    Development of high-throughput ATR-FTIR technology for rapid triage of brain cancer

    Get PDF
    Non-specific symptoms, as well as the lack of a cost-effective test to triage patients in primary care, has resulted in increased time-to-diagnosis and a poor prognosis for brain cancer patients. A rapid, cost-effective, triage test could significantly improve this patient pathway. A blood test using attenuated total reflection (ATR)-Fourier transform infrared (FTIR) spectroscopy for the detection of brain cancer, alongside machine learning technology, is advancing towards clinical translation. However, whilst the methodology is simple and does not require extensive sample preparation, the throughput of such an approach is limited. Here we describe the development of instrumentation for the analysis of serum that is able to differentiate cancer and control patients at a sensitivity and specificity of 93.2% and 92.8%. Furthermore, preliminary data from the first prospective clinical validation study of its kind are presented, demonstrating how this innovative technology can triage patients and allow rapid access to imaging

    Comparability of Raman Spectroscopic Configurations: A Large Scale Cross-Laboratory Study

    Get PDF
    This is the final version. Available on open access from the American Chemical Society via the DOI in this recordThe variable configuration of Raman spectroscopic platforms is one of the major obstacles in establishing Raman spectroscopy as a valuable physicochemical method within real-world scenarios such as clinical diagnostics. For such real world applications like diagnostic classification, the models should ideally be usable to predict data from different setups. Whether it is done by training a rugged model with data from many setups or by a primary-replica strategy where models are developed on a 'primary' setup and the test data are generated on 'replicate' setups, this is only possible if the Raman spectra from different setups are consistent, reproducible, and comparable. However, Raman spectra can be highly sensitive to the measurement conditions, and they change from setup to setup even if the same samples are measured. Although increasingly recognized as an issue, the dependence of the Raman spectra on the instrumental configuration is far from being fully understood and great effort is needed to address the resulting spectral variations and to correct for them. To make the severity of the situation clear, we present a round robin experiment investigating the comparability of 35 Raman spectroscopic devices with different configurations in 15 institutes within seven European countries from the COST (European Cooperation in Science and Technology) action Raman4clinics. The experiment was developed in a fashion that allows various instrumental configurations ranging from highly confocal setups to fibre-optic based systems with different excitation wavelengths. We illustrate the spectral variations caused by the instrumental configurations from the perspectives of peak shifts, intensity variations, peak widths, and noise levels. We conclude this contribution with recommendations that may help to improve the inter-laboratory studies.COST (European Cooperation in Science and Technology)Portuguese Foundation for Science and TechnologyNational Research Fund of Luxembourg (FNR)China Scholarship Council (CSC)BOKU Core Facilities Multiscale ImagingDeutsche Forschungsgemeinschaft (DFG, German Research Foundation
    corecore