1,134 research outputs found

    Transmission measurement at 10.6 microns of Te2As3Se5 rib-waveguides on As2S3 substrate

    Full text link
    The feasibility of chalcogenide rib waveguides working at lambda = 10.6 microns has been demonstrated. The waveguides comprised a several microns thick Te2As3Se5 film deposited by thermal evaporation on a polished As2S3 glass substrate and further etched by physical etching in Ar or CF4/O2 atmosphere. Output images at 10.6 microns and some propagation losses roughly estimated at 10dB/cm proved that the obtained structures behaved as channel waveguides with a good lateral confinement of the light. The work opens the doors to the realisation of components able to work in the mid and thermal infrared up to 20 microns and even more.Comment: The following article appeared in Vigreux-Bercovici et al., Appl. Phys. Lett. 90, 011110 (2007) and may be found at http://link.aip.org/link/?apl/90/01111

    Safe liquid scintillators for large scale detectors

    Full text link
    Many experiments in particle physics, in particular in the field of neutrino searches, rely on organic liquid scintillators as target and detection material. The size of these detectors was continously growing in the last decades, up to the kiloton scale. In several cases these detectors are located at sites with enhanced safety requirements as underground laboratories or in the vicinity of nuclear reactors. Therefore, there is strong demand in liquids which are safe with respect to aspects as fire protection, human health or environmental pollution. In particular, properties as the flash point, the vapor pressure or the toxicity need to be significantly improved as compared to classical solvents such as xylene or pseudocumene. We present and compare the performance and optical properties of scintillators based on high flash point solvents. In particular polysiloxane based scintillators are characterized by outstanding properties in terms of safety.Comment: 13 pages, 4 figure

    Safe liquid scintillators for large scale detectors

    Get PDF
    Many experiments in particle physics, in particular in the field of neutrino searches, rely on organic liquid scintillators as target and detection material. The size of these detectors was continously growing in the last decades, up to the kiloton scale. In several cases these detectors are located at sites with enhanced safety requirements as underground laboratories or in the vicinity of nuclear reactors. Therefore, there is strong demand in liquids which are safe with respect to aspects as fire protection, human health or environmental pollution. In particular, properties as the flash point, the vapor pressure or the toxicity need to be significantly improved as compared to classical solvents such as xylene or pseudocumene. We present and compare the performance and optical properties of scintillators based on high flash point solvents. In particular polysiloxane based scintillators are characterized by outstanding properties in terms of safety

    Cytotoxics compounded sterile preparation control by HPLC during a 16-month assessment in a French university hospital: importance of the mixing bags step

    Get PDF
    The Centralized Chemotherapy Reconstitution Unit (CCRU) of Paul Brousse Hospital Pharmacy Department assessed the reliability of its Cytotoxics Compounded Sterile Products (CCSP) preparation method in order to improve its CCSP quality assurance system. Five cytotoxic drugs — gemcitabine, 5-fluorouracil, docetaxel, paclitaxel, and oxaliplatin — were assayed by high performance liquid chromatography (HPLC) to determine CCSP concentration. During the observation period, 23,892 CCSP were prepared. Overall, 12,964 preparations contained one of the five analyzed drugs; 7382 (56.9%) out of 12,964 CCSP were analyzed by HPLC; 646 (8.8%) out of 7382 concentrations were outside ± 20% of the prescribed dose; 544 (84.2%) out of 646 were post-administration results and could not be verified. Out of 102 (15.8%) pre-administration results that were re-tested after re-shaking, 94 (92.2%) were found to be acceptable upon re-testing, and 8 (7.8%) were confirmed to be unacceptable and needed to be re-compounded. The 8.8% of tested CCSP were outside ± 20% of the prescribed dose, but extrapolating the results on re-tested CCSP, we can say that our CCSP preparation is reliable with an estimation of only 0.7% of 7382 CCSP analyzed, confirmed as being ± 20% outside the prescribed dose. Nevertheless, this ± 20% magnitude of error should be reduced. Based on pre-administration results, the primary cause of concentration errors appeared to be insufficient mixing of the finished product. Most CCSP dosages occurred after it had been administered, the organization should, therefore, be improved to include testing all CCSP prior to administration. Pharmaceutical companies should endeavor to manufacture compounded injectible drugs in a ‘ready to use’ form and provide vehicles in accurate volumes in order to improve compounding precision

    Photometric quality of Dome C for the winter 2008 from ASTEP South

    Get PDF
    ASTEP South is an Antarctic Search for Transiting Exo- Planets in the South pole field, from the Concordia station, Dome C, Antarctica. The instrument consists of a thermalized 10 cm refractor observing a fixed 3.88\degree x 3.88\degree field of view to perform photometry of several thousand stars at visible wavelengths (700-900 nm). The first winter campaign in 2008 led to the retrieval of nearly 1600 hours of data. We derive the fraction of photometric nights by measuring the number of detectable stars in the field. The method is sensitive to the presence of small cirrus clouds which are invisible to the naked eye. The fraction of night-time for which at least 50% of the stars are detected is 74% from June to September 2008. Most of the lost time (18.5% out of 26%) is due to periods of bad weather conditions lasting for a few days ("white outs"). Extended periods of clear weather exist. For example, between July 10 and August 10, 2008, the total fraction of time (day+night) for which photometric observations were possible was 60%. This confirms the very high quality of Dome C for nearly continuous photometric observations during the Antarctic winter

    An effect size statistical framework for investigating sexual dimorphism in non-avian dinosaurs and other extinct taxa

    Get PDF
    Despite reports of sexual dimorphism in extinct taxa, such claims in non-avian dinosaurs have been underrepresented recently (~the last decade) and often criticized. Since dimorphism is widespread in sexually reproducing organisms today, underrepresentation might suggest either methodological shortcomings or that this diverse group exhibited highly unusual reproductive biology. Univariate significance testing, especially for bimodality, is ineffective and prone to false negatives. Species recognition and mutual sexual selection hypotheses, therefore, may not be required to explain supposed absence of sexual dimorphism across the grade, likely a type II error. Instead, multiple lines of evidence support sexual selection and variation of structures consistent with secondary sexual characteristics, strongly suggesting sexual dimorphism in non-avian dinosaurs. We propose a framework for studying sexual dimorphism in fossils, focusing on likely secondarily sexual traits and testing against all alternate hypotheses for variation in them using multiple lines of evidence. We use effect size statistics appropriate for low sample sizes, rather than significance testing, to analyze potential divergence of growth curves in traits and constrain estimates for dimorphism magnitude. In many cases, estimates of sexual variation can be reasonably accurate, and further developments in methods to improve sex assignments and account for intrasexual variation (e.g., mixture modelling) will improve accuracy. It is better to compare estimates for the magnitude of and support for dimorphism between datasets than to dichotomously reject or fail to reject monomorphism in a single species, enabling the study of sexual selection across phylogenies and time. We defend our approach with simulated and empirical data, including dinosaur data, showing that even simple approaches can yield fairly accurate estimates of sexual variation in many cases, allowing for comparison of species with high and low support for sexual variation.Funding provided by: National Science FoundationCrossref Funder Registry ID: http://dx.doi.org/10.13039/100000001Award Number: PLR 1341645 and FRES 192588
    • …
    corecore