25,610 research outputs found
Gravitational Redshift of Emission Lines in the AGN Spectra
The detection of gravitationally redshifted optical emission lines has been
reported just for a few active galaxies. In this paper we give a short overview
of studies that analyzed or exploited the detection of the gravitational
redshift in optical AGN spectra. In addition, we tested the consistency of
gravitational redshift as the physical origin of the redward shifts observed in
their spectra using a sample of 50 Hamburg-ESO intermediate to high
redshift quasars that are among the most luminous quasars known ( erg/s), and are expected to host very massive
black holes. To this aim we modeled the line profile with accretion disk models
around a black hole.Comment: 10 pages, 2 figures, 3 table
A 2 degree-of-freedom SOI-MEMS translation stage with closed loop positioning
This research contains the design, analysis, fabrication, and characterization of a closed loop XY micro positioning stage. The XY micro positioning stage is developed by adapting parallel-kinematic mechanisms, which have been widely used for macro and meso scale positioning systems, to silicon-based micropositioner. Two orthogonal electrostatic comb drives are connected to moving table through 4-bar mechanism and independent hinges which restrict unwanted rotation in 2-degree-of-freedom translational stage. The XY micro positioning stage is fabricated on SOI wafer with three photolithography patterning processes followed by series of DRIE etching and HF etching to remove buried oxide layer to release the end-effector of the device. The fabricated XY micro positioning stage is shown in Fig1 with SEM images. The device provides a motion range of 20 microns in each direction at the driving voltage of 100V. The resonant frequency of the XY stage under ambient conditions is 811 Hz with a high quality factor of 40 achieved from parallel kinematics. The positioning loop is closed using a COTS capacitance-to-voltage conversion IC and a PID controller built in D-space is used to control position with an uncertainty characterized by a standard distribution of 5.24nm and a approximate closed-loop bandwidth of 27Hz. With the positioning loop, the rise time and settling time for closed-loop system are 50ms and 100ms. With sinusoidal input of ω=1Hz, the maximum phase difference of 108nm from reference input is obtained with total motion range of 8μm
Temperature coefficients of crystalline-quartz elastic constants over the cryogenic range [4 K, 15 K]
This paper brings out results of a measurement campaign aiming to determine
the temperature coefficients of synthetic quartz elastic constants at liquid
helium temperature. The method is based on the relationship between the
resonance frequencies of a quartz acoustic cavity and the elastic constants of
the material. The temperature coefficients of the elastic constants are
extracted from experimental frequency-temperature data collected from a set of
resonators of various cut angles, because of the anisotropy of quartz, measured
on the very useful cryogenic range [4 K - 15 K]. The knowledge of these
temperature coefficients would allow to further design either quartz
temperature sensors or conversely frequency-temperature compensated quartz
cuts. With extremely low losses, lower than for the best ones, key
applications of such devices are ultra-low loss mechanical systems used in many
research areas including frequency control and fundamental measurements. The
Eulerian formalism is used in this study to identify the temperature
coefficients.Comment: 6 pages,4 figure
- …
