13 research outputs found

    Current worldwide nuclear cardiology practices and radiation exposure: results from the 65 country IAEA Nuclear Cardiology Protocols Cross-Sectional Study (INCAPS)

    Get PDF
    Aims To characterize patient radiation doses from nuclear myocardial perfusion imaging (MPI) and the use of radiation-optimizing ‘best practices' worldwide, and to evaluate the relationship between laboratory use of best practices and patient radiation dose. Methods and results We conducted an observational cross-sectional study of protocols used for all 7911 MPI studies performed in 308 nuclear cardiology laboratories in 65 countries for a single week in March-April 2013. Eight ‘best practices' relating to radiation exposure were identified a priori by an expert committee, and a radiation-related quality index (QI) devised indicating the number of best practices used by a laboratory. Patient radiation effective dose (ED) ranged between 0.8 and 35.6 mSv (median 10.0 mSv). Average laboratory ED ranged from 2.2 to 24.4 mSv (median 10.4 mSv); only 91 (30%) laboratories achieved the median ED ≤ 9 mSv recommended by guidelines. Laboratory QIs ranged from 2 to 8 (median 5). Both ED and QI differed significantly between laboratories, countries, and world regions. The lowest median ED (8.0 mSv), in Europe, coincided with high best-practice adherence (mean laboratory QI 6.2). The highest doses (median 12.1 mSv) and low QI (4.9) occurred in Latin America. In hierarchical regression modelling, patients undergoing MPI at laboratories following more ‘best practices' had lower EDs. Conclusion Marked worldwide variation exists in radiation safety practices pertaining to MPI, with targeted EDs currently achieved in a minority of laboratories. The significant relationship between best-practice implementation and lower doses indicates numerous opportunities to reduce radiation exposure from MPI globall

    Current worldwide nuclear cardiology practices and radiation exposure : results from the 65 country IAEA Nuclear Cardiology Protocols Cross-Sectional Study (INCAPS)

    Get PDF
    To characterize patient radiation doses from nuclear myocardial perfusion imaging (MPI) and the use of radiation-optimizing 'best practices' worldwide, and to evaluate the relationship between laboratory use of best practices and patient radiation dose. We conducted an observational cross-sectional study of protocols used for all 7911 MPI studies performed in 308 nuclear cardiology laboratories in 65 countries for a single week in March-April 2013. Eight 'best practices' relating to radiation exposure were identified a priori by an expert committee, and a radiation-related quality index (QI) devised indicating the number of best practices used by a laboratory. Patient radiation effective dose (ED) ranged between 0.8 and 35.6 mSv (median 10.0 mSv). Average laboratory ED ranged from 2.2 to 24.4 mSv (median 10.4 mSv); only 91 (30%) laboratories achieved the median ED ≤ 9 mSv recommended by guidelines. Laboratory QIs ranged from 2 to 8 (median 5). Both ED and QI differed significantly between laboratories, countries, and world regions. The lowest median ED (8.0 mSv), in Europe, coincided with high best-practice adherence (mean laboratory QI 6.2). The highest doses (median 12.1 mSv) and low QI (4.9) occurred in Latin America. In hierarchical regression modelling, patients undergoing MPI at laboratories following more 'best practices' had lower EDs. Marked worldwide variation exists in radiation safety practices pertaining to MPI, with targeted EDs currently achieved in a minority of laboratories. The significant relationship between best-practice implementation and lower doses indicates numerous opportunities to reduce radiation exposure from MPI globally

    History and Perspectives of AOFNMB

    No full text

    Both F-18 FDG-avidity and Malignant Shape of Cervical Lymph Nodes on PET/CT after Total Thyroidectomy Predict Resistance to High-dose I-131 Therapy in Patients with Papillary Thyroid Cancer

    No full text
    Objective: Resistance of metastatic lymph nodes (LNs) to high dose I-131 therapy is associated with high morbidity in patients with differentiated thyroid cancer. We evaluated the role of F-18 FDG PET/CT in the prediction of resistance to high dose I-131 therapy in patients with papillary thyroid cancer. Methods: The subjects were 307 patients who underwent total or near total thyroidectomy followed by high dose (5.55-6.66 GBq) I-131 therapy. We divided the patients into three subgroups by visual assessment of regional LNs: FDG-avid LNs with a malignant shape on CT (PET/CT-positive group), FDG-avid LNs with a benign shape on CT (PET/CT-intermediate group) and no FDG-avid lesion (PET/CT-negative group). We measured the maximum SUV (SUVmax) of FDG-avid LNs in each patient. The presence or absence of focal increased uptake of I-131 was evaluated by whole body scan (WBS), and was denoted as WBS-positive group or WBS-negative group, respectively. Resistance to therapy was defined as presence of thyroglobulin (Tg) in serum (Tg ≥1.0 ng/ml) 3-6 months after I-131 therapy. Univariate and multivariate analyses were performed to determine the relationship between resistance to I-131 therapy and various clinico-pathologic variables. Results: PET/CT-positive, intermediate, and negative groups included 20 (6.5%), 44 (14.3%) and 243 (79.2%) patients, respectively. The mean SUVmax was significantly higher in the PET/CT-positive group than that of the PET/CT-intermediate group (4.6 vs. 2.7, P <0.001). Univariate analysis revealed that the PET/CT-positive group (P <0.001), T2-4 stage (P <0.001), N1b stage (P = 0.001), lower dose (5.55 GBq) of I-131 (P <0.001), and the WBS-positive group (P = 0.029) were associated with resistance to therapy. In multivariate analysis, the PET/CT-positive group, lower dose of I-131, N1b stage, and T2-4 stage remained significant with odds ratios of 10.07 (P <0.001), 3.82 (P <0.001), 3.58 (P = 0.001), and 2.53 (P = 0.009), respectively. Conclusion: FDG-avidity and malignant shape of cervical LNs on pre-therapy FDG PET/CT were a strong risk factors predicting resistance to high dose I-131 therapy. A lower dose of administered I-131 (5.55 GBq) and more extensive tumors (T2-4 and N1b) were also associated with resistance to high dose I-131 therapy

    Both F-18 FDG-avidity and Malignant Shape of Cervical Lymph Nodes on PET/CT after Total Thyroidectomy Predict Resistance to High-dose I-131 Therapy in Patients with Papillary Thyroid Cancer

    No full text
    Objective: Resistance of metastatic lymph nodes (LNs) to high dose I-131 therapy is associated with high morbidity in patients with differentiated thyroid cancer. We evaluated the role of F-18 FDG PET/CT in the prediction of resistance to high dose I-131 therapy in patients with papillary thyroid cancer. Methods: The subjects were 307 patients who underwent total or near total thyroidectomy followed by high dose (5.55-6.66 GBq) I-131 therapy. We divided the patients into three subgroups by visual assessment of regional LNs: FDG-avid LNs with a malignant shape on CT (PET/CT-positive group), FDG-avid LNs with a benign shape on CT (PET/CT-intermediate group) and no FDG-avid lesion (PET/CT-negative group). We measured the maximum SUV (SUVmax) of FDG-avid LNs in each patient. The presence or absence of focal increased uptake of I-131 was evaluated by whole body scan (WBS), and was denoted as WBS-positive group or WBS-negative group, respectively. Resistance to therapy was defined as presence of thyroglobulin (Tg) in serum (Tg ≥1.0 ng/ml) 3-6 months after I-131 therapy. Univariate and multivariate analyses were performed to determine the relationship between resistance to I-131 therapy and various clinico-pathologic variables. Results: PET/CT-positive, intermediate, and negative groups included 20 (6.5%), 44 (14.3%) and 243 (79.2%) patients, respectively. The mean SUVmax was significantly higher in the PET/CT-positive group than that of the PET/CT-intermediate group (4.6 vs. 2.7,

    Impact of COVID-19 Pandemic on Cardiovascular Testing in Asia:The IAEA INCAPS-COVID Study

    Get PDF
    Background: The coronavirus disease-2019 (COVID-19) pandemic significantly affected management of cardiovascular disease around the world. The effect of the pandemic on volume of cardiovascular diagnostic procedures is not known. Objectives: This study sought to evaluate the effects of the early phase of the COVID-19 pandemic on cardiovascular diagnostic procedures and safety practices in Asia. Methods: The International Atomic Energy Agency conducted a worldwide survey to assess changes in cardiovascular procedure volume and safety practices caused by COVID-19. Testing volumes were reported for March 2020 and April 2020 and were compared to those from March 2019. Data from 180 centers across 33 Asian countries were grouped into 4 subregions for comparison. Results: Procedure volumes decreased by 47% from March 2019 to March 2020, showing recovery from March 2020 to April 2020 in Eastern Asia, particularly in China. The majority of centers cancelled outpatient activities and increased time per study. Practice changes included implementing physical distancing and restricting visitors. Although COVID testing was not commonly performed, it was conducted in one-third of facilities in Eastern Asia. The most severe reductions in procedure volumes were observed in lower-income countries, where volumes decreased 81% from March 2019 to April 2020. Conclusions: The COVID-19 pandemic in Asia caused significant reductions in cardiovascular diagnostic procedures, particularly in low-income countries. Further studies on effects of COVID-19 on cardiovascular outcomes and changes in care delivery are warranted.</p

    Global Issues of Radiopharmaceutical Access and Availability: a Nuclear Medicine Global Initiative Project.

    No full text
    The Nuclear Medicine Global Initiative (NMGI) was formed in 2012 by 13 international organizations to promote human health by advancing the field of nuclear medicine and molecular imaging by supporting the practice and application of nuclear medicine. The first project focused on standardization of administered activities in pediatric nuclear medicine and resulted in two manuscripts. For its second project the NMGI chose to explore issues impacting on access and availability of radiopharmaceuticals around the world. Methods: Information was obtained by survey responses from 35 countries on available radioisotopes, radiopharmaceuticals and kits for diagnostic and therapeutic use. Issues impacting on access and availability of radiopharmaceuticals in individual countries were also identified. Results: Detailed information on radiopharmaceuticals utilized in each country, and sources of supply, was evaluated. Responses highlighted problems in access particularly due to the reliance on a sole provider, regulatory issues and reimbursement, as well as issues of facilities and workforce particularly in low- and middle-income countries. Conclusion: Strategies to address access and availability of radiopharmaceuticals are outlined, to enable timely and equitable patient access to nuclear medicine procedures worldwide. In the face of disruptions to global supply chains by the COVID-19 outbreak, renewed focus on ensuring reliable supply of radiopharmaceuticals is a major priority for nuclear medicine practice globally

    Worldwide Diagnostic Reference Levels for Single-Photon Emission Computed Tomography Myocardial Perfusion Imaging: Findings From INCAPS

    Full text link
    OBJECTIVES This study sought to establish worldwide and regional diagnostic reference levels (DRLs) and achievable administered activities (AAAs) for single-photon emission computed tomography (SPECT) myocardial perfusion imaging (MPI). BACKGROUND Reference levels serve as radiation dose benchmarks to compare individual laboratories against aggregated data, helping to identify sites in greatest need of dose reduction interventions. DRLs for SPECT MPI have previously been derived from national or regional registries. To date there have been no multiregional reports of DRLs for SPECT MPI from a single standardized dataset. METHODS Data were submitted voluntarily to the INCAPS (International Atomic Energy Agency Nuclear Cardiology Protocols Study), a cross-sectional, multinational registry of MPI protocols. A total of 7,103 studies were included. DRLs and AAAs were calculated by protocol for each world region and for aggregated worldwide data. RESULTS The aggregated worldwide DRLs for rest-stress or stress-rest studies employing technetium Tc 99m-labeled radiopharmaceuticals were 11.2 mCi (first dose) and 32.0 mCi (second dose) for 1-day protocols, and 23.0 mCi (first dose) and 24.0 mCi (second dose) for multiday protocols. Corresponding AAAs were 10.1 mCi (first dose) and 28.0 mCi (second dose) for 1-day protocols, and 17.8 mCi (first dose) and 18.7 mCi (second dose) for multiday protocols. For stress-only technetium Tc 99m studies, the worldwide DRL and AAA were 18.0 mCi and 12.5 mCi, respectively. Stress-first imaging was used in 26% to 92% of regional studies except in North America where it was used in just 7% of cases. Significant differences in DRLs and AAAs were observed between regions. CONCLUSIONS This study reports reference levels for SPECT MPI for each major world region from one of the largest international registries of clinical MPI studies. Regional DRLs may be useful in establishing or revising guidelines or simply comparing individual laboratory protocols to regional trends. Organizations should continue to focus on establishing standardized reporting methods to improve the validity and comparability of regional DRLs

    Current worldwide nuclear cardiology practices and radiation exposure: results from the 65 country IAEA Nuclear Cardiology Protocols Cross-Sectional Study (INCAPS)

    No full text
    To characterize patient radiation doses from nuclear myocardial perfusion imaging (MPI) and the use of radiation-optimizing 'best practices' worldwide, and to evaluate the relationship between laboratory use of best practices and patient radiation dose. We conducted an observational cross-sectional study of protocols used for all 7911 MPI studies performed in 308 nuclear cardiology laboratories in 65 countries for a single week in March-April 2013. Eight 'best practices' relating to radiation exposure were identified a priori by an expert committee, and a radiation-related quality index (QI) devised indicating the number of best practices used by a laboratory. Patient radiation effective dose (ED) ranged between 0.8 and 35.6 mSv (median 10.0 mSv). Average laboratory ED ranged from 2.2 to 24.4 mSv (median 10.4 mSv); only 91 (30%) laboratories achieved the median ED ≤ 9 mSv recommended by guidelines. Laboratory QIs ranged from 2 to 8 (median 5). Both ED and QI differed significantly between laboratories, countries, and world regions. The lowest median ED (8.0 mSv), in Europe, coincided with high best-practice adherence (mean laboratory QI 6.2). The highest doses (median 12.1 mSv) and low QI (4.9) occurred in Latin America. In hierarchical regression modelling, patients undergoing MPI at laboratories following more 'best practices' had lower EDs. Marked worldwide variation exists in radiation safety practices pertaining to MPI, with targeted EDs currently achieved in a minority of laboratories. The significant relationship between best-practice implementation and lower doses indicates numerous opportunities to reduce radiation exposure from MPI globally
    corecore