18 research outputs found

    A VALIDITY STUDY COMPARING XSENS WITH VICON

    Get PDF
    Conducting on-field measurements is warranted to investigate and reduce real-world anterior cruciate ligament (ACL) injury risk. However, validation is first warranted to ensure how Xsens relates to Vicon. The purpose of this study was therefore to compare lower extremity kinematics from Xsens with Vicon. Ten recreational ball team sport athletes (5 females, 5 males) were included, who performed isolated and dynamic movements. Strong correlations were found for movement patterns (\u3e0.7) for the isolated as well as the dynamics movements. However, absolute joint angles differ between both systems (ranging from 0.7º - 14.5º). This should be considered when using Xsens in an applied sport setting as drawing conclusions for being or not being at risk for ACL injury may depend on the system used. A major strength of this study is the inclusion of movements that are restricted to one plane and one joint as well as dynamic high-intensity movements resembling movements which occur in sports (e.g. change of direction). This analysis of methods of data collection leads to further advancement of knowledge the science of biomechanics in applied sports setting

    An ecological dynamics approach to ACL injury risk research:a current opinion

    Get PDF
    Research of non-contact anterior cruciate ligament (ACL) inj1ury risk aims to identify modifiable risk factors that are linked to the mechanisms of injury. Information from these studies is then used in the development of injury prevention programmes. However, ACL injury risk research often leans towards methods with three limitations: 1) a poor preservation of the athlete-environment relationship that limits the generalisability of results, 2) the use of a strictly biomechanical approach to injury causation that is incomplete for the description of injury mechanisms, 3) and a reductionist analysis that neglects profound information regarding human movement. This current opinion proposes three principles from an ecological dynamics perspective that address these limitations. First, it is argued that, to improve the generalisability of findings, research requires a well-preserved athlete-environment relationship. Second, the merit of including behaviour and the playing situation in the model of injury causation is presented. Third, this paper advocates that research benefits from conducting non-reductionist analysis (i.e., more holistic) that provides profound information regarding human movement. Together, these principles facilitate an ecological dynamics approach to injury risk research that helps to expand our understanding of injury mechanisms and thus contributes to the development of preventative measures

    American College of Rheumatology Provisional Criteria for Clinically Relevant Improvement in Children and Adolescents With Childhood-Onset Systemic Lupus Erythematosus

    Get PDF
    10.1002/acr.23834ARTHRITIS CARE & RESEARCH715579-59

    Concurrent validation of the Noraxon MyoMotion wearable inertial sensors in change-of-direction and jump-landing tasks

    No full text
    Wearable inertial sensors (WIS) facilitate the preservation of the athlete-environment relationship by allowing measurement outside the laboratory. WIS systems should be validated for team sports movements before they are used in sports performance and injury prevention research. The aim of the present study was to investigate the concurrent validity of a wearable inertial sensor system in quantifying joint kinematics during team sport movements. Ten recreationally active participants performed change-of-direction (single-leg deceleration and sidestep cut) and jump-landing (single-leg hop, single-leg crossover hop, and double-leg vertical jump) tasks while motion was recorded by nine inertial sensors (Noraxon MyoMotion, Noraxon USA Inc.) and eight motion capture cameras (Vicon Motion Systems Ltd). Validity of lower-extremity joint kinematics was assessed using measures of agreement (cross-correlation: XCORR) and error (root mean square deviation; and amplitude difference). Excellent agreement (XCORR >0.88) was found for sagittal plane kinematics in all joints and tasks. Highly variable agreement was found for frontal and transverse plane kinematics at the hip and ankle. Errors were relatively high in all planes. In conclusion, the WIS system provides valid estimates of sagittal plane joint kinematics in team sport movements. However, researchers should correct for offsets when comparing absolute joint angles between systems

    Concurrent validation of the Xsens IMU system of lower-body kinematics in jump-landing and change-of-direction tasks

    Get PDF
    Inertial measurement units (IMUs) allow for measurements of kinematic movements outside the laboratory, persevering the athlete-environment relationship. To use IMUs in a sport-specific setting, it is necessary to validate sport-specific movements. The aim of this study was to assess the concurrent validity of the Xsens IMU system by comparing it to the Vicon optoelectronic motion system for lower-limb joint angle measurements during jump-landing and change-of-direction tasks. Ten recreational athletes performed four tasks; single-leg hop and landing, running double-leg vertical jump landing, single-leg deceleration and push off, and sidestep cut, while kinematics were recorded by 17 IMUs (Xsens Technologies B.V.) and eight motion capture cameras (Vicon Motion Systems, Ltd). Validity of lower-body joint kinematics was assessed using measures of agreement (cross-correlation: XCORR) and error (root mean square deviation and amplitude difference). Excellent agreement was found in the sagittal plane for all joints and tasks (XCORR > 0.92). Highly variable agreement was found for knee and ankle in transverse and frontal plane. Relatively high error rates were found in all joints. In conclusion, this study shows that the Xsens IMU system provides highly comparable waveforms of sagittal lower-body joint kinematics in sport-specific movements. Caution is advised interpreting frontal and transverse plane kinematics as between-system agreement highly varied
    corecore