19 research outputs found

    Ventilator-Free Day Outcomes Can Be Misleading

    No full text
    International audienceINTRODUCTION: Acute respiratory distress syndrome often requires invasive mechanical ventilation, with both mortality and mechanical ventilation duration as outcomes of interest. The concept of ventilator-free days has been proposed as an outcome combining these two outcomes. Here we analyzed the construction of the ventilator-free day outcome and provided a hypothetical scenario to alert physicians that such an outcome can lead to misleading interpretations. METHODS: We proposed the isoventilator-free day curve concept and, using an analytical development, illustrated how a median ventilator-free day value can actually result from very different combinations of death rates and mechanical ventilation durations. We also used a hypothetical example to compare the Student t test, Wilcoxon rank-sum test, and Gray test (which accounts for death as a competing event with extubation) in comparing exposition to mechanical ventilation. RESULTS: A median ventilator-free day value of 10 days may mean that 10% of the patients died while survivors were ventilated during a median of 14 days or that 40% died while survivors were ventilated during a median of 5 days. Changing the time horizon affected the Student t test but not the Wilcoxon rank-sum result. The Gray test was more relevant than both the Student t test and Wilcoxon rank-sum test in identifying differences in groups showing highly different mechanical ventilation duration, despite equal median ventilator-free days. This approach was also illustrated using real data. CONCLUSIONS: Use of ventilator-free days as an outcome appears to have many drawbacks. Suitable methods of analyzing time to extubation should be preferred

    Lack of impact of iodinated contrast media on kidney cell-cycle arrest biomarkers in critically ill patients

    No full text
    Abstract Background Iodinated contrast media may contribute to acute kidney injury. However, several recent works suggest that this toxicity is minimal in the clinical setting. Recently, urinary G1 cell-cycle arrest proteins tissue inhibitor of metalloproteinase 2 (TIMP-2) and insulin like growth factor binding protein 7 (IGFBP-7) were identified as highly sensitive and specific biomarkers for early detection of kidney aggression. The impact of contrast administration on those biomarkers has not been specifically evaluated but could provide clues about the toxicity of contrast media. This study aimed at measuring changes in TIMP-2 and IGFBP-7 urinary concentrations before and after a contrast-enhanced computed tomography in critically ill patients. Methods 77 patients were included in a prospective observational cohort study. Urinary [TIMP -2]·[IGFBP-7] was measured before, 6 and 24 h after contrast infusion. Urine output and serum creatinine were followed 3 days. Results Median [TIMP-2]·[IGFBP-7] was 0.06 [interquartile range 0.04;0.26], 0.07 [0.03;0.34] and 0.10 [0.04;0.37] (ng/mL)2/1000 respectively before, 6 and 24 h after contrast infusion. Individual changes from baseline were − 0.01 [− 0.11;0.11] and 0.00 [− 0.10;0.09] (ng/ml)2/1000 at 6 and 24 h. These changes were not higher among the patients increasing their Kidney Disease Improving Global Outcome (KDIGO) classification within 3 days after contrast infusion (n = 14 [18%] based on creatinine criterion only, n = 42 [55%] based on creatinine and urine output). Conclusions Changes in [TIMP-2]·[IGFBP-7] urinary concentration after contrast-enhanced computed tomography were insignificant, suggesting minimal kidney aggression by modern iodinated contrast media

    Methodological quality of multivariate prognostic models for intracranial haemorrhages in intensive care units: a systematic review

    No full text
    International audienceObjectives Patients with severe spontaneous intracranial haemorrhages, managed in intensive care units, face ethical issues regarding the difficulty of anticipating their recovery. Prognostic tools help clinicians in counselling patients and relatives and guide therapeutic decisions. We aimed to methodologically assess prognostic tools for functional outcomes in severe spontaneous intracranial haemorrhages. Data sources Following Preferred Reporting Items for Systematic Reviews and Meta-Analyses recommendations, we conducted a systematic review querying Medline, Embase, Web of Science, and the Cochrane in January 2020. Study selection We included development or validation of multivariate prognostic models for severe intracerebral or subarachnoid haemorrhage. Data extraction We evaluated the articles following the CHecklist for critical Appraisal and data extraction for systematic Reviews of prediction Modelling Studies and Transparent Reporting of multivariable prediction model for Individual Prognosis Or Diagnosis statements to assess the tools’ methodological reporting. Results Of the 6149 references retrieved, we identified 85 articles eligible. We discarded 43 articles due to the absence of prognostic performance or predictor selection. Among the 42 articles included, 22 did not validate models, 6 developed and validated models and 14 only externally validated models. When adding 11 articles comparing developed models to existing ones, 25 articles externally validated models. We identified methodological pitfalls, notably the lack of adequate validations or insufficient performance levels. We finally retained three scores predicting mortality and unfavourable outcomes: the IntraCerebral Haemorrhages (ICH) score and the max-ICH score for intracerebral haemorrhages, the SubArachnoid Haemorrhage International Trialists score for subarachnoid haemorrhages. Conclusions Although prognostic studies on intracranial haemorrhages abound in the literature, they lack methodological robustness or show incomplete reporting. Rather than developing new scores, future authors should focus on externally validating and updating existing scores with large and recent cohorts

    Nasal high-flow bronchodilator nebulization: a randomized cross-over study

    No full text
    Abstract Background There is an absence of controlled clinical data showing bronchodilation effectiveness after nebulization via nasal high-flow therapy circuits. Results Twenty-five patients with reversible airflow obstruction received, in a randomized order: (1) 2.5 mg albuterol delivered via a jet nebulizer with a facial mask; (2) 2.5 mg albuterol delivered via a vibrating mesh nebulizer placed downstream of a nasal high-flow humidification chamber (30 L/min and 37 °C); and (3) nasal high-flow therapy without nebulization. All three conditions induced significant individual increases in forced expiratory volume in one second (FEV1) compared to baseline. The median change was similar after facial mask nebulization [+ 350 mL (+ 180; + 550); + 18% (+ 8; + 30)] and nasal high flow with nebulization [+ 330 mL (+ 140; + 390); + 16% (+ 5; + 24)], p = 0.11. However, it was significantly lower after nasal high-flow therapy without nebulization [+ 50 mL (− 10; + 220); + 3% (− 1; + 8)], p = 0.0009. FEV1 increases after facial mask and nasal high-flow nebulization as well as residual volume decreases were well correlated (p < 0.0001 and p = 0.01). Both techniques showed good agreement in terms of airflow obstruction reversibility (kappa 0.60). Conclusion Albuterol vibrating mesh nebulization within a nasal high-flow circuit induces similar bronchodilation to standard facial mask jet nebulization. Beyond pharmacological bronchodilation, nasal high flow by itself may induce small but significant bronchodilation

    Salbutamol Nebulization During Noninvasive Ventilation in Exacerbated Chronic Obstructive Pulmonary Disease Patients: A Randomized Controlled Trial

    No full text
    International audienceBackground: Although nebulizing beta 2-agonists during noninvasive ventilation (NIV) could prove helpful, this administration route has to date never been studied in unstable chronic obstructive pulmonary disease (COPD) patients. We sought to demonstrate that salbutamol could be nebulized through an NIV circuit in COPD exacerbation and improve forced expiratory volume in 1 second (FEV1) as compared with placebo.Patient and Methods: This is a bench study to determine the optimal pattern of nebulization followed by a randomized double-blind parallel-group trial comparing salbutamol and placebo aerosols delivered during NIV to 43 intensive care unit patients. Aerosols were generated by a vibrating mesh nebulizer positioned just after the Y-piece. Spirometry was performed immediately before and at several predetermined time points after nebulization. Clinical and biological safety parameters were recorded.Results: We failed to demonstrate a difference between salbutamol and placebo when changes in FEV1 were assessed immediately after nebulization (−20 vs. −35 mL, p = 0.66). However, FEV1 increased significantly from baseline to 40 minutes after the end of salbutamol nebulization, as compared with placebo (+30 vs. −50 mL, p = 0.04). Nebulization was well tolerated.Conclusion: When assessing FEV1 changes 40 minutes after the end of 5 mg salbutamol nebulization in patients undergoing NIV, we observed a slight improvement that was statistically significant compared with the changes observed with an equivalent saline volume

    Perceived inequity, professional and personal fulfillment by women intensivists in France

    No full text
    International audienceBackground: The medical workforce has been feminized for the last two decades worldwide. Nonetheless, women remain under-represented among intensivists. We conducted a survey among French women intensivists to assess their professional and personal quality of life and their perception of potential gender discrimination at work.Methods: We conducted an observational descriptive study by sending a survey, designed by the group FEMMIR (FEmmes Médecins en Médecine Intensive Réanimation), to women intensivists in France, using primarily the Société de Réanimation de Langue Française (SRLF) mailing list. The questionnaire was also available online between September 2019 and January 2020 and women intensivists were encouraged to answer through email reminders. It pertained to five main domains, including demographic characteristics, work position, workload and clinical/research activities, self-fulfillment scale, perceived discrimination at work and suggested measures to implement.Results: Three hundred and seventy-one women responded to the questionnaire, among whom 16% had an academic position. Being a woman intensivist and pregnancy were both considered to increase difficulties in careers’ advancement by 31% and 73% of the respondents, respectively. Almost half of the respondents (46%) quoted their quality of life equal to or lower than 6 on a scale varying from 1 (very bad quality of life) to 10 (excellent quality of life). They were 52% to feel an imbalance between their personal and professional life at the cost of their personal life. Gender discrimination has been experienced by 55% of the respondents while 37% confided having already been subject of bullying or harassment. Opportunities to adjust their work timetable including part-time work, better considerations for pregnant women including increasing the number of intensivists and the systematic replacement during maternity leave, and the respect of the law regarding the paternity leave were suggested as key measures to enable better professional and personal accomplishment by women intensivists.Conclusion: In this first large French survey in women intensivists, we pointed out issues felt by women intensivists that included an imbalance between professional and personal life, a perceived loss of opportunity due to the fact of being a woman, frequent reported bullying or harassment and a lack of consideration of the needs related to pregnancy and motherhood

    Glomerular Hyper- and Hypofiltration During Acute Circulatory Failure

    No full text
    International audienceObjective: To assess glomerular filtration rate in the early phase of acute circulatory failure by measuring iohexol plasma clearance.Design: Interventional prospective multicentric study.Setting: Three French ICUs in tertiary teaching hospitals.Patients: Patients with acute circulatory failure within 12 hours after ICU admission.Interventions: IV administration of a nontoxic 5-mL dose of iohexol. Collection of nine arterial blood samples over 24 hours for iohexol plasma concentration measurements. Iohexol clearance calculation with a population pharmacokinetic model. Iohexol clearance was an estimation of the mean glomerular filtration rate over 24 hours.Measurements and Main Results: Among 99 included patients, we could calculate iohexol clearance for 85. The median iohexol clearance was 31 mL/min (interquartile range, 16–44). According to iohexol clearance, 41 patients (48%) had severe hypofiltration (clearance, 130 mL/min). Urinary creatinine clearance underestimated renal impairment in one patient out of two; the bias of iohexol clearance toward 24-hour urinary creatinine clearance over the same period was –18.1 mL/min (limits of agreement, –73.5 to 37.4).Conclusions: We demonstrated the feasibility of iohexol clearance measurement in unstable critically ill patients. Normal kidney function is exceptional during the early phase of acute circulatory failure. Glomerular filtration rate estimation by urinary creatinine clearance frequently fails to detect renal impairment. Hyperfiltration is very infrequent
    corecore