435 research outputs found

    Influence of Heat Transfer and Material Temperature on Combustion Instabilities in a Swirl Burner

    Get PDF
    The current work focuses on the large eddy simulation (LES) of combustion instability in a laboratory-scale swirl burner. Air and fuel are injected at ambient conditions. Heat conduction from the combustion chamber to the plenums results in a preheating of the air and fuel flows above ambient conditions. The paper compares two computations: In the first computation, the temperature of the injected reactants is 300 K (equivalent to the experiment) and the combustor walls are treated as adiabatic. The frequency of the unstable mode ( 635 Hz) deviates significantly from the measured frequency ( 750 Hz). In the second computation, the preheating effect observed in the experiment and the heat losses at the combustion chamber walls are taken into account. The frequency ( 725 Hz) of the unstable mode agrees well with the experiment. These results illustrate the impor- tance of accounting for heat transfer/losses when applying LES for the prediction of com- bustion instabilities. Uncertainties caused by unsuitable modeling strategies when using computational fluid dynamics for the prediction of combustion instabilities can lead to an improper design of passive control methods (such as Helmholtz resonators) as these are often only effective in a limited frequency range

    Improved Source/Absorber Preparation for Radionuclide Spectrometry Based on Low-Temperature Calorimetric Detectors

    Get PDF
    High-resolution beta spectrometry based on low-temperature calorimetric detectors requires high-quality source/absorber combinations in order to avoid spectrum artifacts and to achieve optimal detection efficiency. In this work, preparation techniques and quality control methods to fabricate reliable source/absorber assemblies with the radionuclide under investigation embedded into them are discussed. © 2019, The Author(s)

    Numerical evaluation of a novel double-concentric swirl burner for sulfur combustion

    Get PDF
    A burner system for the efficient and clean combustion of sulfur is introduced, which serves as a key component in a novel solar power cycle using sulfur as chemical storage medium of solar energy. In order to validate the proposed design concept, highly-resolved numerical simulations have been performed. The current setup is operated with a thermal load of 20 kW or power density of 5 MW/m3^{3}. Two nozzle configurations with different swirl intensities (SI) of the airflow are studied. A large inner recirculation zone is observed for the nozzle with a high SI (HSI), which leads to a strong radial dispersion of the sulfur spray and a broad, short flame in the combustion chamber; although this HSI design is beneficial from the viewpoint of flame stabilization, it causes a large number of sulfur droplets hitting the chamber wall. In contrast, the nozzle design with a low SI (LSI) yields a narrow spray and a long jet flame, with much less droplets hitting the wall. The HSI nozzle shows an overall higher flame temperature compared with the LSI nozzle, which is confirmed to be caused by burning at a higher local fuel equivalence ratio. This is attributed to the strong inner recirculation flow generated by the high swirl intensity, which results in an enhanced evaporation and mixing of sulfur droplets with air. In terms of operability and NOx emission, the LSI burner is preferred due to less sulfur droplets hitting the chamber wall and the lower flame temperature

    MetroMMC: Electron-Capture Spectrometry with Cryogenic Calorimeters for Science and Technology

    Get PDF
    Accurate decay data of radionuclides are necessary for many fields of science and technology, ranging from medicine and particle physics to metrology. However, data that are in use today are mostly based on measurements or theoretical calculation methods that are rather old. Recent measurements with cryogenic detectors and other methods show significant discrepancies to both older experimental data and theory in some cases. Moreover, the old results often suffer from large or underestimated uncertainties. This is in particular the case for electron-capture (EC) decays, where only a few selected radionuclides have ever been measured. To systematically address these shortcomings, the European metrology project MetroMMC aims at investigating six radionuclides decaying by EC. The nuclides are chosen to cover a wide range of atomic numbers Z, which results in a wide range of decay energies and includes different decay modes, such as pure EC or EC accompanied by γ- and/or β+-transitions. These will be measured using metallic magnetic calorimeters (MMCs), cryogenic energy-dispersive detectors with high-energy resolution, low-energy threshold and high, adjustable stopping power that are well suited for measurements of the total decay energy and X-ray spectrometry. Within the MetroMMC project, these detectors are used to obtain X-ray emission intensities of external sources as well as fractional EC probabilities of sources embedded in a 4 π absorber. Experimentally determined nuclear and atomic data will be compared to state-of-the-art theoretical calculations which will be further developed within the project. This contribution introduces the MetroMMC project and in particular its experimental approach. The challenges in EC spectrometry are to adapt the detectors and the source preparation to the different decay channels and the wide energy range involved, while keeping the good resolution and especially the low-energy threshold to measure the EC from outer shells. © 2019, The Author(s)

    Existence of radial stationary solutions for a system in combustion theory

    Full text link
    In this paper, we construct radially symmetric solutions of a nonlinear noncooperative elliptic system derived from a model for flame balls with radiation losses. This model is based on a one step kinetic reaction and our system is obtained by approximating the standard Arrehnius law by an ignition nonlinearity, and by simplifying the term that models radiation. We prove the existence of 2 solutions using degree theory

    Robot-assisted and fluorescence-guided remnant-cholecystectomy: a prospective dual-center cohort study

    Get PDF
    Background: Abdominal symptoms after cholecystectomy may be caused by gallstones in a remnant gallbladder or a long cystic duct stump. Resection of a remnant gallbladder or cystic duct stump is associated with an increased risk of conversion and bile duct or vascular injuries. We prospectively investigated the additional value of robotic assistance and fluorescent bile duct illumination in redo biliary surgery.Methods: In this prospective two-centre observational cohort study, 28 patients were included with an indication for redo biliary surgery because of remnant stones in a remnant gallbladder or long cystic duct stump. Surgery was performed with the da Vinci X & REG; and Xi & REG; robotic system. The biliary tract was visualised in the fluorescence Firefly & REG; mode shortly after intravenous injection of indocyanine green.Results: There were no conversions or perioperative complications, especially no vascular or bile duct injuries. Fluorescence-based illumination of the extrahepatic bile ducts was successful in all cases. Symptoms were resolved in 27 of 28 patients. Ten patients were treated in day care and 13 patients were discharged the day after surgery.Conclusion: Robot-assisted fluorescence-guided surgery for remnant gallbladder or cystic duct stump resection is safe, effective and can be done in day-care setting.Surgical oncolog

    Serum calcitonin negative Medullary thyroid carcinoma

    Get PDF
    BACKGROUND: Medullary thyroid carcinomas (MTC) constitute about 5 to 7 % of thyroid neoplasms. They originate from parafollicular C cells which produce Calcitonin, a hormone which has an impact on calcium metabolism and represents the biochemical activity of MTC. In rare cases pre-operative serum calcitonin can be negative. CASE PRESENTATION: We report on a 73-year-old female patient with a rare case of a serum calcitonin negative medullary thyroid carcinoma who suffered fulminant post-operative course and died of multiple metastasis. CONCLUSION: This case shows that in very rare cases MTCs do not secrete calcitonin making diagnosis and tumour follow-up difficult. To this date, only few reports describing this combination of circumstances were found in the English literature
    corecore