287 research outputs found

    A Unified Compression Framework for Efficient Speech-Driven Talking-Face Generation

    Full text link
    Virtual humans have gained considerable attention in numerous industries, e.g., entertainment and e-commerce. As a core technology, synthesizing photorealistic face frames from target speech and facial identity has been actively studied with generative adversarial networks. Despite remarkable results of modern talking-face generation models, they often entail high computational burdens, which limit their efficient deployment. This study aims to develop a lightweight model for speech-driven talking-face synthesis. We build a compact generator by removing the residual blocks and reducing the channel width from Wav2Lip, a popular talking-face generator. We also present a knowledge distillation scheme to stably yet effectively train the small-capacity generator without adversarial learning. We reduce the number of parameters and MACs by 28×\times while retaining the performance of the original model. Moreover, to alleviate a severe performance drop when converting the whole generator to INT8 precision, we adopt a selective quantization method that uses FP16 for the quantization-sensitive layers and INT8 for the other layers. Using this mixed precision, we achieve up to a 19×\times speedup on edge GPUs without noticeably compromising the generation quality.Comment: MLSys Workshop on On-Device Intelligence, 2023; Demo: https://huggingface.co/spaces/nota-ai/compressed_wav2li

    Differential associations of central and brachial blood pressure with carotid atherosclerosis and microvascular complications in patients with type 2 diabetes

    Get PDF
    BACKGROUND: We examined the relationship between central blood pressure (BP), brachial BP with carotid atherosclerosis and microvascular complications in type 2 diabetes mellitus (T2DM). METHODS: We recruited 201 patients who were evaluated for central BP, brachial BP, carotid ultrasonography, brachial-ankle pulse wave velocity (baPWV), ankle-brachial index (ABI) and microvascular complications. Central BP were calculated using a radial automated tonometric system. RESULTS: Agreement between central BP and brachial BP was very strong (concordance correlation coefficient between central and brachial SBP = 0.889, between central and brachial PP = 0.816). Central pulse pressure (PP) was correlated with mean carotid intima-media thickness (CIMT), baPWV and ABI, whereas brachial PP was borderline significantly correlated with CIMT. The prevalence of nephropathy(DN) and retinopathy(DR) according to the brachial PP tertiles increased, the prevalences of microvascular complications were not different across central PP tertiles. In multivariate analysis, the relative risks (RRs) for the presence of DR were 1.2 and 4.6 for the brachial PP tertiles 2 and 3 when compared with the first tertile. Also, the RRs for the presence of DN were 1.02 and 3 for the brachial PP tertiles 2 and 3 when compared with the first tertile. CONCLUSIONS: Agreement of central BP and brachial BP was very strong. Nonetheless, this study showed that higher brachial PP levels are associated with increased probability for the presence of microvascular complications such as DR/DN. However, there are no associations with central SBP and central PP with microvascular complications. Central BP levels than brachial BP are correlated with surrogate marker of macrovascular complications

    Fabrication and evaluation of bilateral Helmholtz radiofrequency coil for thermo-stable breast image with reduced artifacts

    Get PDF
    PURPOSE: The positron emission tomography (PET)-magnetic resonance (MR) system is a newly emerging technique that yields hybrid images with high-resolution anatomical and metabolic information. With PET-MR imaging, a definitive diagnosis of breast abnormalities will be possible with high spatial accuracy and images will be acquired for the optimal fusion of anatomic locations. Therefore, we propose a PET-compatible two-channel breast MR coil with minimal disturbance to image acquisition which can be used for simultaneous PET-MR imaging in patients with breast cancer. MATERIALS AND METHODS: For coil design and construction, the conductor loops of the Helmholtz coil were tuned, matched, and subdivided with nonmagnetic components. Element values were optimized with an electromagnetic field simulation. Images were acquired on a GE 600 PET-computed tomography (CT) and GE 3.0 T MR system. For this study, we used the T1-weighted image (volunteer; repetition time (TR), 694 ms; echo time (TE), 9.6 ms) and T2-weighted image (phantom; TR, 8742 ms; TE, 104 ms) with the fast spin-echo sequence. RESULTS: The results of measuring image factors with the proposed radiofrequency (RF) coil and standard conventional RF coil were as follows: signal-to-noise ratio (breast; 207.7 vs. 175.2), percent image uniformity (phantom; 89.22%-91.27% vs. 94.63%-94.77%), and Hounsfield units (phantom; -4.51 vs. 2.38). CONCLUSIONS: Our study focused on the feasibility of proposed two-channel Helmholtz loops (by minimizing metallic components and soldering) for PET-MR imaging and found the comparable image quality to the standard conventional coil. We believe our work will help significantly to improve image quality with the development of a less metallic breast MR coil

    Primary Large Cell Neuroendocrine Carcinoma of the Breast: Radiologic and Pathologic Findings

    Get PDF
    Some breast neoplasms are classified as primary neuroendocrine carcinomas because they are positive for neuroendocrine markers. Although neuroendocrine carcinomas can originate from various organs of the body, primary neuroendocrine carcinomas of the breast are extremely rare. The diagnosis of primary neuroendocrine carcinoma of the breast can only be made if nonmammary sites are confidently excluded or if an in situ component can be found. Here we report a primary large-cell neuroendocrine carcinoma (LCNL) involving the left breast. Breast ultrasonography revealed a lobulated, heterogeneous, low-echoic mass in the left breast, and the lesion ap-peared as a well-defined, highly-enhancing mass on a chest computed tomography scan. Ultrasound-guided core needle biopsy was performed on the mass, and primary LCNC was confirmed by histopathologic examination

    Brief Education on Microvasculature and Pit Pattern for Trainees Significantly Improves Estimation of the Invasion Depth of Colorectal Tumors

    Get PDF
    Objectives. This study was performed to evaluate the effectiveness of education for trainees on the gross findings identified by conventional white-light endoscopy (CWE), the microvascular patterns identified by magnifying narrow-band imaging endoscopy (MNE), and the pit patterns identified by magnifying chromoendoscopy (MCE) in estimation of the invasion depth of colorectal tumors. Methods. A total of 420 endoscopic images of 35 colorectal tumors were used. Five trainees estimated the invasion depth of the tumors by reviewing the CWE images before education. Afterwards, the trainees estimated the invasion depth of the same tumors after brief education on CWE, MNE and MCE images, respectively. Results. The initial diagnostic accuracy for deep submucosal invasion before education and after education on CWE, MNE, and MCE findings was 54.3%, 55.4%, 67.4%, and 76.6%, respectively. The diagnostic accuracy increased significantly after MNE education (P=0.028). The specificity for deep submucosal invasion before education and after education on CWE, MNE, and MCE findings was 47.9%, 45.7%, 65.0%, and 80.7%, respectively. The specificity increased significantly after MNE (P=0.002) and MCE (P=0.005) education. Conclusion. Brief education on microvascular pattern identification by MNE and pit pattern identification by MCE significantly improves trainees’ estimations of the invasion depth of colorectal tumors

    The assessment of efficacy of porcine reproductive respiratory syndrome virus inactivated vaccine based on the viral quantity and inactivation methods

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>There have been many efforts to develop efficient vaccines for the control of porcine reproductive and respiratory syndrome virus (PRRSV). Although inactivated PRRSV vaccines are preferred for their safety, they are weak at inducing humoral immune responses and controlling field PRRSV infection, especially when heterologous viruses are involved.</p> <p>Results</p> <p>In all groups, the sample to positive (S/P) ratio of IDEXX ELISA and the virus neutralization (VN) titer remained negative until challenge. While viremia did not reduce in the vaccinated groups, the IDEXX-ELISA-specific immunoglobulin G increased more rapidly and to significantly greater levels 7 days after the challenge in all the vaccinated groups compared to the non-vaccinated groups (<it>p </it>< 0.05). VN titer was significantly different in the 10<sup>6 </sup>PFU/mL PRRSV vaccine-inoculated and binary ethylenimine (BEI)-inactivated groups 22 days after challenge (<it>p </it>< 0.05). Consequently, the inactivated vaccines tested in this study provided weak memory responses with sequential challenge without any obvious active immune responses in the vaccinated pigs.</p> <p>Conclusions</p> <p>The inactivated vaccine failed to show the humoral immunity, but it showed different immune response after the challenge compared to mock group. Although the 10<sup>6 </sup>PFU/mL-vaccinated and BEI-inactivated groups showed significantly greater VN titers 22 days after challenge, all the groups were already negative for viremia.</p

    A Case of Intestinal Behcet's Disease Similar to Crohn's Colitis

    Get PDF
    Behcet's disease is a multi-systemic vasculitis and characterized by systemic organ involvement. Although the gastrointestinal and systemic features of Behcet's disease and inflammatory bowel disease overlap to a considerable extent, they are generally viewed as two distinct diseases. A 39-yr-old female was diagnosed as having Behcet's disease. She was admitted to our hospital because of oral and genital ulcer, lower abdominal pain, and frequent diarrhea. Colonosopy showed diffuse involvement of multiple longitudinal ulcers with inflammatory pseudopolyps with a cobblestone appearance and ano-rectal fistula was suspected. These findings are extremely rare in Behcet's disease. However, there were no granulomas, the hallmark of Crohn's colitis. Microscopically, perivasculitis and multiple lymph follicles compatible with Behcet's disease were seen. Although being rarely encountered, multiple longitudinal ulcers, cobblestone appearance, and ano-rectal fistula can develop in Behcet's disease, as in Crohn's colitis. Therefore, Behcet's disease and Crohn's disease may be closely related and part of a spectrum of disease

    Influence of Diaphragmatic Mobility on Hypercapnia in Patients with Chronic Obstructive Pulmonary Disease

    Get PDF
    A reduction in diaphragm mobility has been identified in patients with chronic obstructive pulmonary disease (COPD) and has been associated with a decline in pulmonary function parameters. However, little information exists regarding the potential role of diaphragm mobility on hypercapnia in COPD. A new method of assessing the mobility of the diaphragm, using ultrasound, has recently been validated. The purpose of the present study was to investigate the relationship between diaphragm mobility and pulmonary function parameters, as well as that between arterial blood gas values and diaphragm mobility, in COPD patients. Thirty seven COPD patients were recruited for pulmonary function test, arterial blood gas analysis and diaphragm mobility using ultrasound to measure the craniocaudal displacement of the left branch of the portal vein. There were significant negative correlations between diaphragmatic mobility and PaCO2 (r = -0.373, P = 0.030). Diaphragmatic mobility correlated with airway obstruction (FEV1, r = 0.415, P = 0.011) and with ventilatory capacity (FVC, r = 0.302, P = 0.029; MVV, r = 0.481, P = 0.003). Diaphragmatic mobility also correlated significantly with pulmonary hyperinflation. No relationship was observed between diaphragm mobility and PaO2 (r = -0.028, P = 0.873). These findings support a possibility that the reduction in diaphragm mobility relates to hypercapnia in COPD patients
    corecore