19 research outputs found

    Biological Impact of γ-Fe2O3 Magnetic Nanoparticles Obtained by Laser Target Evaporation: Focus on Magnetic Biosensor Applications

    Get PDF
    The biological activity of γ-Fe2O3 magnetic nanoparticles (MNPs), obtained by the laser target evaporation technique, was studied, with a focus on their possible use in biosensor applications. The biological effect of the MNPs was investigated in vitro on the primary cultures of human dermal fibroblasts. The effects of the MNPs contained in culture medium or MNPs already uptaken by cells were evaluated for the cases of the fibroblast’s proliferation and secretion of cytokines and collagen. For the tests related to the contribution of the constant magnetic field to the biological activity of MNPs, a magnetic system for the creation of the external magnetic field (having no commercial analogues) was designed, calibrated, and used. It was adapted to the size of standard 24-well cell culture plates. At low concentrations of MNPs, uptake by fibroblasts had stimulated their proliferation. Extracellular MNPs stimulated the release of pro-inflammatory cytokines (Interleukin-6 (IL-6) and Interleukin-8 (IL-8) or chemokine (C-X-C motif) ligand 8 (CXCL8)) in a concentration-dependent manner. However, the presence of MNPs did not increase the collagen secretion. The exposure to the uniform constant magnetic field (H ≈ 630 or 320 Oe), oriented in the plane of the well, did not cause considerable changes in fibroblasts proliferation and secretion, regardless of presence of MNPs. Statistically significant differences were detected only in the levels of IL-8/CXCL8 release.The study was supported by the program of the Ministry of Health of the Russian Federation (project 121032300335-1). This work was financially supported, in part, by the Ministry of Science and Higher Education of the RF (grant FEUZ-2020-0051) (G.Yu. Melnikov) and University of the Basque Country Research Groups Funding (grant IT1245-19) (G.V. Kurlyandskaya)

    Polyacrylamide Ferrogels with Magnetite or Strontium Hexaferrite: Next Step in the Development of Soft Biomimetic Matter for Biosensor Applications

    Get PDF
    Magnetic biosensors are an important part of biomedical applications of magnetic materials. As the living tissue is basically a " soft matter." this study addresses the development of ferrogels (FG) with micron sized magnetic particles of magnetite and strontium hexaferrite mimicking the living tissue. The basic composition of the FG comprised the polymeric network of polyacrylamide, synthesized by free radical polymerization of monomeric acrylamide (AAm) in water solution at three levels of concentration (1.1 M, 0.85 M and 0.58 M) to provide the FG with varying elasticity. To improve FG biocompatibility and to prevent the precipitation of the particles, polysaccharide thickeners-guar gum or xanthan gum were used. The content of magnetic particles in FG varied up to 5.2 wt % depending on the FG composition. The mechanical properties of FG and their deformation in a uniform magnetic field were comparatively analyzed. FG filled with strontium hexaferrite particles have larger Young's modulus value than FG filled with magnetite particles, most likely due to the specific features of the adhesion of the network's polymeric subchains on the surface of the particles. FG networks with xanthan are stronger and have higher modulus than the FG with guar. FG based on magnetite, contract in a magnetic field 0.42 T, whereas some FG based on strontium hexaferrite swell. Weak FG with the lowest concentration of AAm shows a much stronger response to a field, as the concentration of AAm governs the Young's modulus of ferrogel. A small magnetic field magnetoimpedance sensor prototype with Co68.6Fe3.9Mo3.0Si12.0B12.5 rapidly quenched amorphous ribbon based element was designed aiming to develop a sensor working with a disposable stripe sensitive element. The proposed protocol allowed measurements of the concentration dependence of magnetic particles in gels using magnetoimpedance responses in the presence of magnetite and strontium hexaferrite ferrogels with xanthan. We have discussed the importance of magnetic history for the detection process and demonstrated the importance of remnant magnetization in the case of the gels with large magnetic particles.This work was supported in part within the framework of the state task of the Ministry of Education and Science of Russia 3.6121.2017/8.9; RFBR grant 16-08-00609 and by the ACTIMAT grant of the Basque Country Government. Selected studies were made at SGIKER Common Services of UPV-EHU and URFU Common Services. We thank I.V. Beketov, A.A. Svalova, Burgoa Beitia, A. Amirabadizadeh, A. Garcia-Arribas and I. Orue for their special support

    Mechanical, Electrical and Magnetic Properties of Ferrogels with Embedded Iron Oxide Nanoparticles Obtained by Laser Target Evaporation: Focus on Multifunctional Biosensor Applications

    Get PDF
    Hydrogels are biomimetic materials widely used in the area of biomedical engineering and biosensing. Ferrogels (FG) are magnetic composites capable of functioning as magnetic field sensitive transformers and field assisted drug deliverers. FG can be prepared by incorporating magnetic nanoparticles (MNPs) into chemically crosslinked hydrogels. The properties of biomimetic ferrogels for multifunctional biosensor applications can be set up by synthesis. The properties of these biomimetic ferrogels can be thoroughly controlled in a physical experiment environment which is much less demanding than biotests. Two series of ferrogels (soft and dense) based on polyacrylamide (PAAm) with different chemical network densities were synthesized by free-radical polymerization in aqueous solution with N, N'-methylene-diacrylamide as a cross-linker and maghemite Fe2O3 MNPs fabricated by laser target evaporation as a filler. Their mechanical, electrical and magnetic properties were comparatively analyzed. We developed a giant magnetoimpedance (MI) sensor prototype with multilayered FeNi-based sensitive elements deposited onto glass or polymer substrates adapted for FG studies. The MI measurements in the initial state and in the presence of FG with different concentrations of MNPs at a frequency range of 1-300 MHz allowed a precise characterization of the stray fields of the MNPs present in the FG. We proposed an electrodynamic model to describe the MI in multilayered film with a FG layer based on the solution of linearized Maxwell equations for the electromagnetic fields coupled with the Landau-Lifshitz equation for the magnetization dynamics.This work was supported in part within the framework of the state task of the Ministry of Education and Science of Russia 3.6121.2017/8.9; RFBR grants 16-08-00609-a, 18-08-00178, and by the ACTIMAT ELKARTEK grant of the Basque Country Government. Selected studies were made at SGIKER Common Services of UPV-EHU and URFU Common Services. We thank I.V. Beketov, A.A. Chlenova, S.O. Volchkov, V.N. Lepalovskij, A.M. Murzakaev and A.A. Svalova for special support

    Validity of ejection fraction as a measure of myocardial functional state: impact of asynchrony

    Get PDF
    Aims The goal of this study was to test whether peculiarities of left ventricular (LV) regional function place limits on the validity of ejection fraction (EF) as a measure of the myocardial functional state. Methods and results Transthoracic and transoesophageal data from patients with a variety of cardiac conditions were used for analysis of LV regional function. The focus was on the effects of mechanical asynchrony. Ejection fraction was calculated on the basis of LV end-diastolic volume and end-systolic volume obtained by two different ways: (i) end-systolic volume as a whole; and (ii) the sum of all regional end-systolic volumes (which may occur at different times). The relative difference, D-EF, between EFs obtained by (i) and (ii) was taken as the ‘merit ’ of EF. A value of zero is the highest merit. Irrespective of the examination method, we found that D-EF was always higher than zero, and that its value depended on the extent of mechanical asynchrony. Conclusions Ejection fraction is not the arithmetic average of regional EFs. An increase of asynchrony increases D-EF, i.e. it reduces the merit of EF as a measure of cardiac function

    Do we need a new educational standard for higher medical education?

    No full text
    The authors strongly argue that the role of fundamental knowledge in the course of physicians’ training is evidently underestimated. This paper addresses to a wide readership auditory, and its aim is an invitation for a comprehensive discussion of the future of higher medical education

    Stepwise Length Changes in Single Invertebrate Thick Filaments

    Get PDF
    ABSTRACT Previous experiments on thick filaments of the anterior byssus retractor muscle of Mytilus and the telson-levator muscle of Limulus polyphemus have shown large, reversible length changes up to 23 % and 66 % of initial length, respectively, within the physiological tension range. Using nanofabricated cantilevers and newly developed high-resolution detection methods, we investigated the dynamics of isolated Mytilus anterior byssus retractor muscle thick filaments. Single thick filaments were suspended between the tips of two microbeams oriented perpendicular to the filament axis: a deflectable cantilever and a stationary beam. Axial stress was applied by translating the base of the deflectable nanolever away from the stationary beam, which bent the nanolever. Tips of flexible nanolevers and stationary beam were imaged onto a photodiode array to track their positions. Filament shortening and lengthening traces, obtained immediately after the motor had imposed stress on the filament, showed steps and pauses. Step sizes were 2.7 nm and integer multiples thereof. Steps of this same size paradigm have been seen both during contraction of single sarcomeres and during active interaction between single isolated actin and myosin filaments, raising the question whether all of these phenomena might be related

    English Language in Medical Informatics Teaching: Opinion of Students

    No full text
    The paper describes an interdisciplinary experience of teaching one of the modules of medical informatics in English. The interdisciplinary approach was introduced in the Ural State Medical University (USMU). During 2015–2017 academic years, the interdisciplinary team including teachers of the biomedical physics, informatics and mathematics department and foreign languages department of USMU were developing and introducing integrative classes on medical informatics in English. In total, 287 students of general medicine, pediatrics, dentistry and preventive medicine faculties participated in the survey concerning integrative training in medical informatics in English. Evaluation of both foreign language communication skills and abilities to search medical information in international databases was performed during practical studies. 76% of medical students responded positively to the opportunity to improve foreign language communication skills for professional purposes. We find it possible to develop some modules of professional disciplines in English to teach medical students
    corecore