139 research outputs found
Recommended from our members
Flourishing workplaces: a multisensory approach to design and POE
How can we design workplaces which occupants thrive in, which are functional but are also expressive? Drawing on research about the senses and office related studies this paper demonstrates how buildings can be designed to allow for positive multi-sensory experiences. In order to design a creative and productive workplace, it is essential to consider how the environment is making us feel, behave and act within it. As the workplace continues to evolve, the case is made for a sensory palette framework to drive a systems approach to building environmental design enabling the integration of the multi-modal sensory relationship of people’s reactions within various environmental settings. Technological advances, in the form of wearables that monitor our physiological and stress responses offer the opportunity to capture empirical data, further enabling the investigation to see how a diverse range of environmental settings affect our physical, mental and social wellbeing. The paper goes on to develop the established conceptual theories of ‘Flourish’ proposing a move beyond comfort when designing the interiors and the mechanics of facility controls towards a sensory impacts framework that considers a whole life costing approach using the Flourish Model sets the basis for a design and post-occupancy evaluation toolkit
Indoor environmental quality and occupant satisfaction in green-certified buildings
Green building certification systems aim at improving the design and operation of buildings. However, few detailed studies have investigated whether green rating leads to higher occupant satisfaction with indoor environmental quality (IEQ). This research builds on previous work to address this. Based on the analysis of a subset of the Center for the Built Environment Occupant Indoor Environmental Quality survey database featuring 11,243 responses from 93 LEED-rated office buildings, we explored the relationships between the points earned in the IEQ category and the satisfaction expressed by occupants with the qualities of their indoor environment. We found that the achievement of a specific IEQ credit did not substantively increase satisfaction with the corresponding IEQ factor, while the rating level, and the product and version under which certification had been awarded, did not affect workplace satisfaction. There could be several reasons for this lack of relationships, some of which are outside the control of designers and beyond the scope of rating systems based primarily on design intent. We conclude with a discussion of the challenges and priorities that building professionals, researchers, and green building certification systems need to consider for moving us towards more comfortable, higher performing, and healthier green-rated buildings
SARS-CoV-2 incidence in secondary schools; the role of national and school-initiated COVID-19 measures
INTRODUCTION: Our aim was to gain insight into the effect of COVID-19 measures on SARS-CoV-2 incidence in secondary schools and the association with classroom CO 2 concentration and airborne contamination. METHODS: Between October 2020-June 2021, 18 schools weekly reported SARS-CoV-2 incidence and completed surveys on school-initiated COVID-19 measures (e.g. improving hygiene or minimizing contacts). CO 2 was measured in occupied classrooms twice, and SARS-CoV-2 air contamination longitudinally using electrostatic dust collectors (EDC) and analyzed using RT-qPCR. National COVID-19 policy measures varied during pre-lockdown, lockdown and post-lockdown periods. During the entire study, schools were recommended to improve ventilation. SARS-CoV-2 incidence rate ratios (IRR) were estimated by Generalized Estimating Equation (GEE) models. RESULTS: During 18 weeks follow-up (range: 10-22) SARS-CoV-2 school-incidence decreased during national lockdown (adjusted IRR: 0.41, 95%CI: 0.21-0.80) and post-lockdown (IRR: 0.60, 0.39-0.93) compared to pre-lockdown. School-initiated COVID-19 measures had no additional effect. Pre-lockdown, IRRs per 10% increase in time CO 2 exceeded 400, 550 and 800 ppm above outdoor level respectively, were 1.08 (1.00-1.16), 1.10 (1.02-1.19), and 1.08 (0.95-1.22). Post-lockdown, CO 2-concentrations were considerably lower and not associated with SARS-CoV-2 incidence. No SARS-CoV-2 RNA was detected in any of the EDC samples. CONCLUSION: During a period with low SARS-CoV-2 population immunity and increased attention to ventilation, with CO 2 levels most of the time below acceptable thresholds, only the national policy during and post-lockdown of reduced class-occupancy, stringent quarantine, and contact testing reduced SARS-CoV-2 incidence in Dutch secondary schools. Widespread SARS-CoV-2 air contamination could not be demonstrated in schools under the prevailing conditions during the study
SARS-CoV-2 incidence in secondary schools: the role of national and school-initiated COVID-19 measures
INTRODUCTION: Our aim was to gain insight into the effect of COVID-19 measures on SARS-CoV-2 incidence in secondary schools and the association with classroom CO 2 concentration and airborne contamination. METHODS: Between October 2020-June 2021, 18 schools weekly reported SARS-CoV-2 incidence and completed surveys on school-initiated COVID-19 measures (e.g. improving hygiene or minimizing contacts). CO 2 was measured in occupied classrooms twice, and SARS-CoV-2 air contamination longitudinally using electrostatic dust collectors (EDC) and analyzed using RT-qPCR. National COVID-19 policy measures varied during pre-lockdown, lockdown and post-lockdown periods. During the entire study, schools were recommended to improve ventilation. SARS-CoV-2 incidence rate ratios (IRR) were estimated by Generalized Estimating Equation (GEE) models. RESULTS: During 18 weeks follow-up (range: 10-22) SARS-CoV-2 school-incidence decreased during national lockdown (adjusted IRR: 0.41, 95%CI: 0.21-0.80) and post-lockdown (IRR: 0.60, 0.39-0.93) compared to pre-lockdown. School-initiated COVID-19 measures had no additional effect. Pre-lockdown, IRRs per 10% increase in time CO 2 exceeded 400, 550 and 800 ppm above outdoor level respectively, were 1.08 (1.00-1.16), 1.10 (1.02-1.19), and 1.08 (0.95-1.22). Post-lockdown, CO 2-concentrations were considerably lower and not associated with SARS-CoV-2 incidence. No SARS-CoV-2 RNA was detected in any of the EDC samples. CONCLUSION: During a period with low SARS-CoV-2 population immunity and increased attention to ventilation, with CO 2 levels most of the time below acceptable thresholds, only the national policy during and post-lockdown of reduced class-occupancy, stringent quarantine, and contact testing reduced SARS-CoV-2 incidence in Dutch secondary schools. Widespread SARS-CoV-2 air contamination could not be demonstrated in schools under the prevailing conditions during the study
Recommended from our members
Creative and productive workplaces: a review
The built environment affects our well-being and this in turn influences our effectiveness in the workplace. Poor environments contribute to absenteeism and to people not working as well as they might. This is an enormous cost to the nation. High-quality environmental design is an investment, as occupants are healthier, staff-retention rates are higher, productivity is higher and sustainability ideals are more likely to be met. Workplaces reflect the culture of companies and are places that are not just functional and convenient but give the occupant a wholesome experience in terms of body and spirit
Knock Down of Heat Shock Protein 27 (HspB1) Induces Degradation of Several Putative Client Proteins
Hsp27 belongs to the heat shock protein family and displays chaperone properties in stress conditions by holding unfolded polypeptides, hence avoiding their inclination to aggregate. Hsp27 is often referenced as an anti-cancer therapeutic target, but apart from its well-described ability to interfere with different stresses and apoptotic processes, its role in non-stressed conditions is still not well defined. In the present study we report that three polypeptides (histone deacetylase HDAC6, transcription factor STAT2 and procaspase-3) were degraded in human cancerous cells displaying genetically decreased levels of Hsp27. In addition, these proteins interacted with Hsp27 complexes of different native size. Altogether, these findings suggest that HDAC6, STAT2 and procaspase-3 are client proteins of Hsp27. Hence, in non stressed cancerous cells, the structural organization of Hsp27 appears to be a key parameter in the regulation by this chaperone of the level of specific polypeptides through client-chaperone type of interactions
- …