70 research outputs found

    Rapid and Precise Semi-Automatic Axon Quantification in Human Peripheral Nerves

    Get PDF
    We developed a time-efficient semi-automated axon quantification method using freeware in human cranial nerve sections stained with paraphenylenediamine (PPD). It was used to analyze a total of 1238 facial and masseteric nerve biopsies. The technique was validated by comparing manual and semi-automated quantification of 129 (10.4%) randomly selected biopsies. The software-based method demonstrated a sensitivity of 94% and a specificity of 87%. Semi-automatic axon counting was significantly faster (p<0.001) than manual counting. It took 1hour and 47minutes for all 129 biopsies (averaging 50sec per biopsy, 0.04seconds per axon). The counting process is automatic and does not need to be supervised. Manual counting took 21hours and 6minutes in total (average 9minutes and 49seconds per biopsy, 0.52seconds per axon). Our method showed a linear correlation to the manual counts (R=0.944 Spearman rho). Attempts have been made by several research groups to automate axonal load quantification. These methods often require specific hard- and software and are therefore only accessible to a few specialized laboratories. Our semi-automated axon quantification is precise, reliable and time-sparing using publicly available software and should be useful for an effective axon quantification in various human peripheral nerves

    Quantitative analysis of the anterolateral ossification mass in diffuse idiopathic skeletal hyperostosis of the thoracic spine

    Get PDF
    Diffuse idiopathic skeletal hyperostosis (DISH) is a systemic condition leading to ossification of spinal ligaments and has been shown to behave similarly to ankylosing spondylitis (AS) often leading to unstable hyperextension fractures. Currently, no quantitative data are available on the spatial relationship between the bridging anterolateral ossification mass (ALOM) and the vertebral body/intervertebral disc to explain the propensity in DISH to fracture through the vertebral body instead of through the intervertebral disc as more often seen in AS. Furthermore, no reasonable explanation is available for the typical flowing wax morphology observed in DISH. In the current study, a quantitative analysis of computed tomography (CT) data from human cadaveric specimens with DISH was performed to better understand the newly formed osseous structures and fracture biomechanics. Additionally, the results were verified using computed tomography angiography data from ten patients with DISH and ten controls. Transverse CT images were analyzed to obtain ALOM area and centroid angle relative to the anteroposterior axis; intervertebral disc and adjacent cranial and caudal levels. The ALOM area at the mid-vertebral body level averaged 57.9 ± 50.0 mm2; at the mid-intervertebral disc space level it averaged 246.4 ± 95.9 mm2. The mean ALOM area at the adjacent level caudal to the mid-vertebral body level was 169.6 ± 81.3 mm2; at the adjacent cranial level, it was 161.7 ± 78.2 mm2. The main finding was the significant difference between mean ALOM area at the mid-vertebral body level and other three levels (p < 0.0001). The subsequent verification study showed the presence of vertebral segmental arteries at the mid-vertebral body level in nearly all images irrespective of the presence of DISH. A larger area of ALOM seemed associated with increased counter-clockwise rotation (away from the aorta) of the centroid relative to the anteroposterior axis. The results from the present study suggest a predisposition for fractures through the vertebral body and a role for the arterial system in the inhibition of soft tissue ossification

    Nebuliser therapy in the intensive care unit

    Get PDF
    The relationship between identity, lived experience, sexual practices and the language through which these are conveyed has been widely debated in sexuality literature. For example, ‘coming out’ has famously been conceptualised as a ‘speech act’ (Sedgwick 1990) and as a collective narrative (Plummer 1995), while a growing concern for individuals’ diverse identifications in relations to their sexual and gender practices has produced interesting research focusing on linguistic practices among LGBT-identified individuals (Leap 1995; Kulick 2000; Cameron and Kulick 2006; Farqhar 2000). While an explicit focus on language remains marginal to literature on sexualities (Kulick 2000), issue of language use and translation are seldom explicitly addressed in the growing literature on intersectionality. Yet intersectional perspectives ‘reject the separability of analytical and identity categories’ (McCall 2005:1771), and therefore have an implicit stake in the ‘vernacular’ language of the researched, in the ‘scientific’ language of the researcher and in the relationship of continuity between the two. Drawing on literature within gay and lesbian/queer studies and cross-cultural studies, this chapter revisits debates on sexuality, language and intersectionality. I argue for the importance of giving careful consideration to the language we choose to use as researchers to collectively define the people whose experiences we try to capture. I also propose that language itself can be investigated as a productive way to foreground how individual and collective identifications are discursively constructed, and to unpack the diversity of lived experience. I address intersectional complexity as a methodological issue, where methodology is understood not only as the methods and practicalities of doing research, but more broadly as ‘a coherent set of ideas about the philosophy, methods and data that underlie the research process and the production of knowledge’ (McCall 2005:1774). My points are illustrated with examples drawn from my ethnographic study on ‘lesbian’ identity in urban Russia, interspersed with insights from existing literature. In particular, I aim to show that an explicit focus on language can be a productive way to explore the intersections between the global, the national and the local in cross-cultural research on sexuality, while also addressing issues of positionality and accountability to the communities researched

    The Legal and Ethical Framework Governing Body Donation in Europe - 2nd update on Current Practice.

    Get PDF
    BACKGROUND In 2008, members of the TEPARG provided first insights into the legal and ethical framework governing body donation in Europe. In 2012, a first update followed. This paper is now the second update on this topic and tries to extend the available information to many mor European contries. METHODS For this second update, we have asked authors from all European countries to contribute their national perspectives. By this inquiry, we got many contributions compiled in this paper. When we did not get a personal contribution, one of us (EB) searched the internet for relevant information. RESULTS Perspectives on the legal and ethical framework governing body donation in Europe. CONCLUSIONS We still see that a clear and rigorous legal framework is still unavailable in several countries. We found national regulations in 18 out of 39 countries; two others have at least federal laws. Several countries accept not only donated bodies but also utilise unclaimed bodies. These findings can guide policymakers in reviewing and updating existing laws and regulations related to body donation and anatomical studies

    Trace elements in glucometabolic disorders: an update

    Get PDF
    Many trace elements, among which metals, are indispensable for proper functioning of a myriad of biochemical reactions, more particularly as enzyme cofactors. This is particularly true for the vast set of processes involved in regulation of glucose homeostasis, being it in glucose metabolism itself or in hormonal control, especially insulin. The role and importance of trace elements such as chromium, zinc, selenium, lithium and vanadium are much less evident and subjected to chronic debate. This review updates our actual knowledge concerning these five trace elements. A careful survey of the literature shows that while theoretical postulates from some key roles of these elements had led to real hopes for therapy of insulin resistance and diabetes, the limited experience based on available data indicates that beneficial effects and use of most of them are subjected to caution, given the narrow window between safe and unsafe doses. Clear therapeutic benefit in these pathologies is presently doubtful but some data indicate that these metals may have a clinical interest in patients presenting deficiencies in individual metal levels. The same holds true for an association of some trace elements such as chromium or zinc with oral antidiabetics. However, this area is essentially unexplored in adequate clinical trials, which are worth being performed

    Periosteal vascularization of the distal femur in relation to distal femoral osteotomies: a cadaveric study

    Get PDF
    BACKGROUND: The purpose of this study was to investigate periosteal vessels location as intra-operative landmarks in distal femoral osteotomies and focused on the branching pattern of the vascular supply of the medial and lateral femoral condyle, its constancy, and the relationship to the height of distal femoral osteotomies. Anastomoses of relevant vessels were studied to analyze the risk of vascular insufficiency after transection of landmark vessels. METHODS: A human cadaver dissection study on the vascular supply of the medial and lateral side of the distal femur was conducted. Surgical dissection was performed in eight knees in total. Distances between the vascular supply and bony landmarks were calculated. Relation of the vascular structures to the transverse bone cuts of distal femoral osteotomies was described, as well as anastomoses of relevant vessels. RESULTS: On the medial side of the distal femur the periosteum was primarily supplied by the descending genicular artery (DGA) in 87.5 % of the specimens. In the absence of the DGA, the superior medial genicular artery was the supplier. Vascularization took place through two constant branches, the upper transverse artery (UTA) and the central longitudinal artery. The UTA originated at a mean distance of 6.9 cm (range 5.9-7.9 cm) above the knee joint line. On the lateral side of the distal femur the superior lateral genicular artery was the main vessel. In all dissected knees it gave off the lateral transverse artery (LTA). The LTA originated at a mean distance of 6.9 cm (range 5.8-7.6 cm) above the knee joint line. Anastomoses between the UTA, LTA and the longitudinal arch of the femoral shaft were found that could prevent vascular insufficiencies after transection of the UTA and LTA. CONCLUSIONS: The vascular supply of the medial and lateral aspects of the femoral condyle is highly constant. Both the UTA, on the medial side, and the LTA, on the lateral side, can serve as a landmark for orthopedic surgeons in determining the height of the osteotomy cuts in distal femoral osteotomies. Transection of these landmark vessels during the osteotomy will not result in vascular insufficiency because of a collateral supply

    Periosteal vascularization of the distal femur in relation to distal femoral osteotomies : a cadaveric study

    No full text
    BACKGROUND: The purpose of this study was to investigate periosteal vessels location as intra-operative landmarks in distal femoral osteotomies and focused on the branching pattern of the vascular supply of the medial and lateral femoral condyle, its constancy, and the relationship to the height of distal femoral osteotomies. Anastomoses of relevant vessels were studied to analyze the risk of vascular insufficiency after transection of landmark vessels. METHODS: A human cadaver dissection study on the vascular supply of the medial and lateral side of the distal femur was conducted. Surgical dissection was performed in eight knees in total. Distances between the vascular supply and bony landmarks were calculated. Relation of the vascular structures to the transverse bone cuts of distal femoral osteotomies was described, as well as anastomoses of relevant vessels. RESULTS: On the medial side of the distal femur the periosteum was primarily supplied by the descending genicular artery (DGA) in 87.5 % of the specimens. In the absence of the DGA, the superior medial genicular artery was the supplier. Vascularization took place through two constant branches, the upper transverse artery (UTA) and the central longitudinal artery. The UTA originated at a mean distance of 6.9 cm (range 5.9-7.9 cm) above the knee joint line. On the lateral side of the distal femur the superior lateral genicular artery was the main vessel. In all dissected knees it gave off the lateral transverse artery (LTA). The LTA originated at a mean distance of 6.9 cm (range 5.8-7.6 cm) above the knee joint line. Anastomoses between the UTA, LTA and the longitudinal arch of the femoral shaft were found that could prevent vascular insufficiencies after transection of the UTA and LTA. CONCLUSIONS: The vascular supply of the medial and lateral aspects of the femoral condyle is highly constant. Both the UTA, on the medial side, and the LTA, on the lateral side, can serve as a landmark for orthopedic surgeons in determining the height of the osteotomy cuts in distal femoral osteotomies. Transection of these landmark vessels during the osteotomy will not result in vascular insufficiency because of a collateral supply

    Early ultrasonographic detection of low-volume intraneural injection

    No full text
    Intraneural injection of local anaesthetic agents carries a risk of neurological complications. Early detection of intraneural needle-tip position is very important in the initial phase of injection. Ultrasound (US) characteristics for real-time detection of intraneural injections have been described, but only for relatively large volumes (540 ml). This study assesses the reliability of various US criteria to detect early low volume (0.5 ml) intraneural injections. Intraneural deposition of an injected dye was confirmed by cryomicrotomy. In nine unembalmed human cadavers, 0.5 ml methylene blue was injected intraneurally into the supraclavicular brachial plexus and subgluteal sciatic nerve on both sides. The sites of injection were subsequently removed en bloc. Consecutive cryomicrotomy cross-sections with a 50 m interval were obtained to assess intraneural presence of the injectate. Two independent experts separately reviewed US video clips of the injections and scored each US criterion. Of the 36 injections, cryomicrotome cross-sections showed intraneural staining in 33 and extraneural staining in three. The best US criterion was expansion of the nerve cross-sectional surface area together with a change in echogenicity. It was observed in 35 injections, including two false positives. There was one true negative. Test precision was 94 [95 confidence interval (CI), 87100]. The mean increase in surface area was 8.7 (95 CI, 5.611.9). Reliable detection of early low-volume intraneural injection using US is possible using expansion of the cross-sectional surface area of the nerve together with a change in echogenicity as markers
    corecore