51 research outputs found

    Epigenetic control of nuclear architecture

    Get PDF
    The cell nucleus is a highly structured compartment where nuclear components are thought to localize in non-random positions. Correct positioning of large chromatin domains may have a direct impact on the localization of other nuclear components, and can therefore influence the global functionality of the nuclear compartment. DNA methylation of cytosine residues in CpG dinucleotides is a prominent epigenetic modification of the chromatin fiber. DNA methylation, in conjunction with the biochemical modification pattern of histone tails, is known to lock chromatin in a close and transcriptionally inactive conformation. The relationship between DNA methylation and large-scale organization of nuclear architecture, however, is poorly understood. Here we briefly summarize present concepts of nuclear architecture and current data supporting a link between DNA methylation and the maintenance of large-scale nuclear organization

    Effectiveness of an mHealth intervention combining a smartphone app and smart band on body composition in an overweight and obese population: Randomized controlled trial (EVIDENT 3 study)

    Get PDF
    Background: Mobile health (mHealth) is currently among the supporting elements that may contribute to an improvement in health markers by helping people adopt healthier lifestyles. mHealth interventions have been widely reported to achieve greater weight loss than other approaches, but their effect on body composition remains unclear. Objective: This study aimed to assess the short-term (3 months) effectiveness of a mobile app and a smart band for losing weight and changing body composition in sedentary Spanish adults who are overweight or obese. Methods: A randomized controlled, multicenter clinical trial was conducted involving the participation of 440 subjects from primary care centers, with 231 subjects in the intervention group (IG; counselling with smartphone app and smart band) and 209 in the control group (CG; counselling only). Both groups were counselled about healthy diet and physical activity. For the 3-month intervention period, the IG was trained to use a smartphone app that involved self-monitoring and tailored feedback, as well as a smart band that recorded daily physical activity (Mi Band 2, Xiaomi). Body composition was measured using the InBody 230 bioimpedance device (InBody Co., Ltd), and physical activity was measured using the International Physical Activity Questionnaire. Results: The mHealth intervention produced a greater loss of body weight (–1.97 kg, 95% CI –2.39 to –1.54) relative to standard counselling at 3 months (–1.13 kg, 95% CI –1.56 to –0.69). Comparing groups, the IG achieved a weight loss of 0.84 kg more than the CG at 3 months. The IG showed a decrease in body fat mass (BFM; –1.84 kg, 95% CI –2.48 to –1.20), percentage of body fat (PBF; –1.22%, 95% CI –1.82% to 0.62%), and BMI (–0.77 kg/m2, 95% CI –0.96 to 0.57). No significant changes were observed in any of these parameters in men; among women, there was a significant decrease in BMI in the IG compared with the CG. When subjects were grouped according to baseline BMI, the overweight group experienced a change in BFM of –1.18 kg (95% CI –2.30 to –0.06) and BMI of –0.47 kg/m2 (95% CI –0.80 to –0.13), whereas the obese group only experienced a change in BMI of –0.53 kg/m2 (95% CI –0.86 to –0.19). When the data were analyzed according to physical activity, the moderate-vigorous physical activity group showed significant changes in BFM of –1.03 kg (95% CI –1.74 to –0.33), PBF of –0.76% (95% CI –1.32% to –0.20%), and BMI of –0.5 kg/m2 (95% CI –0.83 to –0.19). Conclusions: The results from this multicenter, randomized controlled clinical trial study show that compared with standard counselling alone, adding a self-reported app and a smart band obtained beneficial results in terms of weight loss and a reduction in BFM and PBF in female subjects with a BMI less than 30 kg/m2 and a moderate-vigorous physical activity level. Nevertheless, further studies are needed to ensure that this profile benefits more than others from this intervention and to investigate modifications of this intervention to achieve a global effect

    Autoantibodies against type I IFNs in patients with life-threatening COVID-19

    Get PDF
    Interindividual clinical variability in the course of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) infection is vast. We report that at least 101 of 987 patients with life-threatening coronavirus disease 2019 (COVID-19) pneumonia had neutralizing immunoglobulin G (IgG) autoantibodies (auto-Abs) against interferon-w (IFN-w) (13 patients), against the 13 types of IFN-a (36), or against both (52) at the onset of critical disease; a few also had auto-Abs against the other three type I IFNs. The auto-Abs neutralize the ability of the corresponding type I IFNs to block SARS-CoV-2 infection in vitro. These auto-Abs were not found in 663 individuals with asymptomatic or mild SARS-CoV-2 infection and were present in only 4 of 1227 healthy individuals. Patients with auto-Abs were aged 25 to 87 years and 95 of the 101 were men. A B cell autoimmune phenocopy of inborn errors of type I IFN immunity accounts for life-threatening COVID-19 pneumonia in at least 2.6% of women and 12.5% of men

    Functional outcomes in symptomatic versus asymptomatic patients undergoing incisional hernia repair: Replacing one problem with another? A prospective cohort study in 1312 patients

    Get PDF
    Background: Incisional hernias can be associated with pain or discomfort. Surgical repair especially mesh reinforcement, may likewise induce pain. The primary objective was to assess the incidence of pain after hernia repair in patients with and without pre-operative pain or discomfort. The secondary objectives were to determine the preferred mesh type, mesh location and surgical technique in minimizing postoperative pain or discomfort. Materials and methods: A registry-based prospective cohort study was performed, including patients undergoing incisional hernia repair between September 2011 and May 2019. Patients with a minimum follow-up of 3–6 months were included. The incidence of hernia related pain and discomfort was recorded perioperatively. Results: A total of 1312 patients were included. Pre-operatively, 1091 (83%) patients reported pain or discomfort. After hernia repair, 961 (73%) patients did not report pain or discomfort (mean follow-up = 11.1 months). Of the pre-operative asymptomatic patients (n = 221), 44 (20%, moderate or severe pain: n = 14, 32%) reported pain or discomfort after mean follow-up of 10.5 months. Of those patients initially reporting pain or discomfort (n = 1091), 307 (28%, moderate or severe pain: n = 80, 26%) still reported pain or discomfort after a mean follow-up of 11.3 months postoperatively. Conclusion: In symptomatic incisional hernia patients, hernia related complaints may be resolved in the majority of cases undergoing surgical repair. In asymptomatic incisional hernia patients, pain or discomfort may be induced in a considerable number of patients due to surgical repair and one should be aware if this postoperative complication

    Luz de Libertad

    No full text

    A polarographic study of the schiff bases of pyridoxal-5'-phosphate. Influence of the amine protonation equilibrium on the stability

    No full text
    Schiff bases obtained from reaction of pyridoxa1-5‘-phosphate with n-hexylamine, L-lysine. N-acetylethylenediamine and tris(hydroxymethyl)-aminomethane were studied by DC and DP polarography, as a function of the pH, the amine concentration arid the solution composition. I-t curves show that the electrochemical processes are diffusion—control led in the limiting current and the apparent constants of the formation equilibrium were determined. A relation between the stability maximum of the Schiff bases and the ionization constants of the amines was observed

    Relaciones entre la Meseta y Oretania

    No full text
    Available from Centro de Informacion y Documentacion Cientifica CINDOC. Joaquin Costa, 22. 28002 Madrid. SPAIN / CINDOC - Centro de Informaciòn y Documentaciòn CientìficaSIGLEESSpai

    Determinacion del termino fuente a partir de medidas de multiplicacion subcritica en el reactor coral-i

    No full text
    Centro de Informacion y Documentacion Cientifica (CINDOC). C/Joaquin Costa, 22. 28002 Madrid. SPAIN / CINDOC - Centro de Informaciòn y Documentaciòn CientìficaSIGLEESSpai

    Metodos de calculo para espectrometria de neutrones en contadores proporcionales

    No full text
    Centro de Informacion y Documentacion Cientifica (CINDOC). C/Joaquin Costa, 22. 28002 Madrid. SPAIN / CINDOC - Centro de Informaciòn y Documentaciòn CientìficaSIGLEESSpai

    Effect of the particle size and solids volume fraction on the thermal degradation behaviour of Invar 36 feedstocks

    No full text
    International audienceDegradation kinetics and the thermal stability of Invar 36 powder injection moulding feedstocks (PIM) based on cellulose acetate butyrate (CAB) and polyethylene glycol (PEG) binders were investigated using simultaneous thermogravimetric analysis (STA) and differential scanning calorimetry (DSC). The initial decomposition temperature (IDT) and the integral procedure decomposition temperature (IPDT) were used to analyse the thermal stability of the binder system as a function of the solid loading content and powder particle size. The degradation kinetics was studied, and the process apparent activation energies were assessed using isoconversional methods. All the methodologies revealed changes in the thermal degradation behaviours of the feedstocks for solid loadings that were previously determined to correspond to optimal solid loadings using other experimental procedures. The studies also contrast previous similar findings with a ceramic powder. Therefore these results strengthen the proposal of thermodynamic degradation studies of feedstocks as an alternative or complementary technique to determine optimal solid loading contents in metal injection moulding (MIM)
    corecore