969 research outputs found

    Enhanced exciton harvesting in a planar heterojunction organic photovoltaic device by solvent vapor annealing

    Get PDF
    The singlet exciton diffusion length was measured in a small molecule electron donor material DR3TBDTT using fluorescence quenching at a planar interface with a cross-linked fullerene derivative. The one-dimensional exciton diffusion length was increased from ~16 to ~24 nm by annealing the film in carbon disulfide solvent vapor. Planar heterojunction solar cells were fabricated using bilayers of these materials and it was found that solvent vapor annealing increased the short circuit current density by 46%. This can be explained by improved exciton harvesting in the annealed bilayer

    Bilateral linear scleroderma "en coup de sabre" associated with facial atrophy and neurological complications

    Get PDF
    BACKGROUND: Linear scleroderma "en coup de sabre" (LSCS) usually affects one side of the face and head in the frontoparietal area with band-like indurated skin lesions. The disease may be associated with facial hemiatrophy. Various ophthalmological and neurological abnormalities have been observed in patients with LSCS. We describe an unusual case of LSC. CASE PRESENTATION: A 23 year old woman presented bilateral LSCS and facial atrophy. The patient had epileptic seizures as well as oculomotor and facial nerve palsy on the left side which also had pronounced skin involvement. Clinical features of different stages of the disease are presented. CONCLUSIONS: The findings of the presented patient with bilateral LSCS and facial atrophy provide further evidence for a neurological etiology of the disease and may also indicate that classic progressive facial hemiatrophy (Parry-Romberg syndrome) and LSCS actually represent different spectra of the same disease

    Fast myocardial T(1) mapping using cardiac motion correction

    Get PDF
    PURPOSE: To improve the efficiency of native and postcontrast high-resolution cardiac T(1) mapping by utilizing cardiac motion correction. METHODS: Common cardiac T(1) mapping techniques only acquire data in a small part of the cardiac cycle, leading to inefficient data sampling. Here, we present an approach in which 80% of each cardiac cycle is used for T(1) mapping by integration of cardiac motion correction. Golden angle radial data was acquired continuously for 8 s with in-plane resolution of 1.3 × 1.3 mm(2). Cine images were reconstructed for nonrigid cardiac motion estimation. Images at different TIs were reconstructed from the same data, and motion correction was performed prior to T(1) mapping. Native T(1) mapping was evaluated in healthy subjects. Furthermore, the technique was applied for postcontrast T(1) mapping in 5 patients with suspected fibrosis. RESULTS: Cine images with high contrast were obtained, leading to robust cardiac motion estimation. Motion-corrected T(1) maps showed myocardial T(1) times similar to cardiac-triggered T(1) maps obtained from the same data (1288 ± 49 ms and 1259 ± 55 ms, respectively) but with a 34% improved precision (spatial variation: 57.0 ± 12.5 ms and 94.8 ± 15.4 ms, respectively, P < 0.0001) due to the increased amount of data. In postcontrast T(1) maps, focal fibrosis could be confirmed with late contrast-enhancement images. CONCLUSION: The proposed approach provides high-resolution T(1) maps within 8 s. Data acquisition efficiency for T(1) mapping was improved by a factor of 5 by integration of cardiac motion correction, resulting in precise T(1) maps

    The Hilbert basis method for D-flat directions and the superpotential

    Get PDF
    We discuss, using the Hilbert basis method, how to efficiently construct a complete basis for D-flat directions in supersymmetric Abelian and non-Abelian gauge theories. We extend the method to discrete (R and non-R) symmetries. This facilitates the construction of a basis of all superpotential terms in a theory with given symmetries.Comment: 11 pages; a related mathematica code can be found at http://einrichtungen.ph.tum.de/T30e/codes/NonAbelianHilbert

    Non-supersymmetric heterotic model building

    Get PDF
    We investigate orbifold and smooth Calabi-Yau compactifications of the non-supersymmetric heterotic SO(16)xSO(16) string. We focus on such Calabi-Yau backgrounds in order to recycle commonly employed techniques, like index theorems and cohomology theory, to determine both the fermionic and bosonic 4D spectra. We argue that the N=0 theory never leads to tachyons on smooth Calabi-Yaus in the large volume approximation. As twisted tachyons may arise on certain singular orbifolds, we conjecture that such tachyonic states are lifted in the full blow-up. We perform model searches on selected orbifold geometries. In particular, we construct an explicit example of a Standard Model-like theory with three generations and a single Higgs field.Comment: 1+30 pages latex, 11 tables; v2: references and minor revisions added, matches version published in JHE

    Enhanced exciton harvesting in a planar heterojunction organic photovoltaic device by solvent vapor annealing

    Get PDF
    We thank the European Research Council (ERC) for financial support (EXCITON grant 321305). Data supporting this study is available at https://doi.org/10.17630/0e75f92d-6f8a-41be-ad45-ac6d1d890ee2.The singlet exciton diffusion length was measured in a small molecule electron donor material DR3TBDTT using fluorescence quenching at a planar interface with a cross-linked fullerene derivative. The one-dimensional exciton diffusion length was increased from ~16 to ~24 nm by annealing the film in carbon disulfide solvent vapor. Planar heterojunction solar cells were fabricated using bilayers of these materials and it was found that solvent vapor annealing increased the short circuit current density by 46%. This can be explained by improved exciton harvesting in the annealed bilayer.PostprintPeer reviewe

    Native myocardial T1 time can predict development of subsequent anthracycline-induced cardiomyopathy

    Get PDF
    Aims: This study aims to assess subclinical changes in functional and morphological myocardial magnetic resonance parameters very early into an anthracycline treatment, which may predict subsequent development of anthracycline-induced cardiomyopathy (aCMP). Methods and results: Thirty sarcoma patients with planned anthracycline-based chemotherapy (360-400 mg/m doxorubicin-equivalent) were recruited. Median treatment time was 19.1 ± 2.1 weeks. Enrolled individuals received three cardiovascular magnetic resonance studies (before treatment, 48 h after first anthracycline treatment, and upon completion of treatment). Native T1 mapping (modified Look-Locker inversion recovery 5s(3s)3s), T2 mapping, and extracellular volume maps were acquired in addition to a conventional cardiovascular magnetic resonance with steady-state free precession cine imaging at 1.5 T. Patients were given 0.2 mmol/kg gadoteridol for extracellular volume quantification and late gadolinium enhancement imaging. Development of relevant aCMP was defined as drop of left ventricular ejection fraction (LVEF) by >10%. For analysis, 23 complete data sets were available. Nine patients developed aCMP with LVEF reduction >10% until end of chemotherapy. Baseline LVEF was not different between patients with and without subsequent aCMP. When assessed 48 h after first dose of antracyclines, patients with subsequent aCMP had significantly lower native myocardial T1 times compared with before therapy (1002.0 ± 37.9 vs. 956.5 ± 29.2 ms, P  0.05). Patients with aCMP had decreased left ventricular mass upon completion of therapy (86.9 ± 24.5 vs. 81.1 ± 22.3 g; P = 0.02), while patients without aCMP did not show a change in left ventricular mass (81.8 ± 21.0 vs. 79.2 ± 18.1 g; P > 0.05). No patient developed new myocardial scars or compact myocardial fibrosis under chemotherapy. Conclusions: Early decrease of T1 times 48 h after first treatment with anthracyclines can predict the development of subsequent aCMP after completion of chemotherapy

    GLSMs for non-Kahler Geometries

    Get PDF
    We identify a simple mechanism by which H-flux satisfying the modified Bianchi identity arises in garden-variety (0,2) gauged linear sigma models. Taking suitable limits leads to effective gauged linear sigma models with Green-Schwarz anomaly cancellation. We test the quantum-consistency of a class of such effective theories by constructing an off-shell superconformal algebra, providing evidence that these models run to good CFTs in the deep IR.Comment: 37 pages, Minor updates for v

    Novel Branches of (0,2) Theories

    Full text link
    We show that recently proposed linear sigma models with torsion can be obtained from unconventional branches of conventional gauge theories. This observation puts models with log interactions on firm footing. If non-anomalous multiplets are integrated out, the resulting low-energy theory involves log interactions of neutral fields. For these cases, we find a sigma model geometry which is both non-toric and includes brane sources. These are heterotic sigma models with branes. Surprisingly, there are massive models with compact complex non-Kahler target spaces, which include brane/anti-brane sources. The simplest conformal models describe wrapped heterotic NS5-branes. We present examples of both types.Comment: 36 pages, LaTeX, 2 figures; typo in Appendix fixed; references added and additional minor change
    • 

    corecore