647 research outputs found

    Industrial GaInP/GaAs Power HBT MMIC Process

    Get PDF
    UMS has developed an industrial power HBT process especially dedicated to power MMICs in the 10GHz frequency range. The process has been qualified and meets the very demanding specifications required for X-Band high power amplifiers. Aside from the obvious RF performances, this includes the demonstration of the necessary stability and reproducibility of the process, associated with state-of-art reliability. It is important to note that the later has been achieved without affecting the high frequency capability of the devices, and demonstrated directly on high power transistors. Thanks to its intrinsic qualities this process can naturally also be used for other applications, like low phase noise voltage controlled oscillators, and power amplifiers at lower frequencies (for mobile phones for instance)

    Investigation of the XCAT phantom as a validation tool in cardiac MRI tracking algorithms.

    Get PDF
    PURPOSE: To describe our magnetic resonance imaging (MRI) simulated implementation of the 4D digital extended cardio torso (XCAT) phantom to validate our previously developed cardiac tracking techniques. Real-time tracking will play an important role in the non-invasive treatment of atrial fibrillation with MRI-guided radiosurgery. In addition, to show how quantifiable measures of tracking accuracy and patient-specific physiology could influence MRI tracking algorithm design. METHODS: Twenty virtual patients were subjected to simulated MRI scans that closely model the proposed real-world scenario to allow verification of the tracking technique's algorithm. The generated phantoms provide ground-truth motions which were compared to the target motions output from our tracking algorithm. The patient-specific tracking error, ep, was the 3D difference (vector length) between the ground-truth and algorithm trajectories. The tracking errors of two combinations of new tracking algorithm functions that were anticipated to improve tracking accuracy were studied. Additionally, the correlation of key physiological parameters with tracking accuracy was investigated. RESULTS: Our original cardiac tracking algorithm resulted in a mean tracking error of 3.7 ± 0.6 mm over all virtual patients. The two combinations of tracking functions demonstrated comparable mean tracking errors however indicating that the optimal tracking algorithm may be patient-specific. CONCLUSIONS: Current and future MRI tracking strategies are likely to benefit from this virtual validation method since no time-resolved 4D ground-truth signal can currently be derived from purely image-based studies

    Bayesian Inference Semantics: A Modelling System and A Test Suite

    Get PDF
    We present BIS, a Bayesian Inference Seman- tics, for probabilistic reasoning in natural lan- guage. The current system is based on the framework of Bernardy et al. (2018), but de- parts from it in important respects. BIS makes use of Bayesian learning for inferring a hy- pothesis from premises. This involves estimat- ing the probability of the hypothesis, given the data supplied by the premises of an argument. It uses a syntactic parser to generate typed syn- tactic structures that serve as input to a model generation system. Sentences are interpreted compositionally to probabilistic programs, and the corresponding truth values are estimated using sampling methods. BIS successfully deals with various probabilistic semantic phe- nomena, including frequency adverbs, gener- alised quantifiers, generics, and vague predi- cates. It performs well on a number of interest- ing probabilistic reasoning tasks. It also sus- tains most classically valid inferences (instan- tiation, de Morgan’s laws, etc.). To test BIS we have built an experimental test suite with examples of a range of probabilistic and clas- sical inference patterns

    Malignant hypertension and acute aortic dissection associated with caffeine-based ephedra-free dietary supplements: a case report

    Get PDF
    The use of weight loss dietary supplements is prevalent in the United States, and over the past decade, there has been tremendous growth of the use of these products. It is well documented that ephedra-based products are associated with various cardiovascular adverse effects. With new restrictions placed on such products, companies are now manufacturing caffeine-based ephedra-free herbal supplements. We present the case of 36-year old, previously healthy female who developed malignant hypertension and aortic dissection while taking various caffeine-based dietary supplements. Given the lack of research studies in regards to their safety and efficacy, judicious care should be taken with the use of dietary supplements, including those designated as ephedra-free

    Calcium-dependent translocation of sorcin to membranes: functional relevance in contractile tissue

    Get PDF
    AbstractSorcin, a 22 kDa calcium binding protein present in abundance in cardiac tissue and in multi-drug resistant cells and previously described as a soluble protein, is now shown to undergo a calcium-dependent translocation process from the cytosol to cellular membranes in both systems. The translocation process takes place also in E. coli BL21 cells that express recombinant sorcin, r-sorcin, and can be exploited in the purification of the protein. Calcium binding to purified r-sorcin occurs at micromolar concentrations of the metal and is accompanied by a conformational change that renders the protein soluble in the non-ionic detergent Triton X-114. This finding suggests that lipids are the target of sorcin on cellular membranes. The possible significance of the calcium-dependent translocation of sorcin in the specialized functions of sorcin-expressing cells is discussed

    Towards real-time MRI-guided 3D localization of deforming targets for non-invasive cardiac radiosurgery.

    Get PDF
    Radiosurgery to the pulmonary vein antrum in the left atrium (LA) has recently been proposed for non-invasive treatment of atrial fibrillation (AF). Precise real-time target localization during treatment is necessary due to complex respiratory and cardiac motion and high radiation doses. To determine the 3D position of the LA for motion compensation during radiosurgery, a tracking method based on orthogonal real-time MRI planes was developed for AF treatments with an MRI-guided radiotherapy system. Four healthy volunteers underwent cardiac MRI of the LA. Contractile motion was quantified on 3D LA models derived from 4D scans with 10 phases acquired in end-exhalation. Three localization strategies were developed and tested retrospectively on 2D real-time scans (sagittal, temporal resolution 100 ms, free breathing). The best-performing method was then used to measure 3D target positions in 2D-2D orthogonal planes (sagittal-coronal, temporal resolution 200-252 ms, free breathing) in 20 configurations of a digital phantom and in the volunteer data. The 3D target localization accuracy was quantified in the phantom and qualitatively assessed in the real data. Mean cardiac contraction was  ⩽  3.9 mm between maximum dilation and contraction but anisotropic. A template matching approach with two distinct template phases and ECG-based selection yielded the highest 2D accuracy of 1.2 mm. 3D target localization showed a mean error of 3.2 mm in the customized digital phantoms. Our algorithms were successfully applied to the 2D-2D volunteer data in which we measured a mean 3D LA motion extent of 16.5 mm (SI), 5.8 mm (AP) and 3.1 mm (LR). Real-time target localization on orthogonal MRI planes was successfully implemented for highly deformable targets treated in cardiac radiosurgery. The developed method measures target shifts caused by respiration and cardiac contraction. If the detected motion can be compensated accordingly, an MRI-guided radiotherapy system could potentially enable completely non-invasive treatment of AF

    From coinductive proofs to exact real arithmetic: theory and applications

    Full text link
    Based on a new coinductive characterization of continuous functions we extract certified programs for exact real number computation from constructive proofs. The extracted programs construct and combine exact real number algorithms with respect to the binary signed digit representation of real numbers. The data type corresponding to the coinductive definition of continuous functions consists of finitely branching non-wellfounded trees describing when the algorithm writes and reads digits. We discuss several examples including the extraction of programs for polynomials up to degree two and the definite integral of continuous maps
    • …
    corecore