8 research outputs found

    Optical characterization of LDEF contaminant film

    Get PDF
    Dark brown molecular film deposits were found at numerous locations on the Long Duration Exposure Facility (LDEF) and have been documented in great detail by several investigators. The exact deposition mechanism for these deposits is as yet unknown, although direct and scattered atomic oxygen, and solar radiation interacting with materials outgassing products have all been implicated in the formation process. Specimens of the brown molecular film were taken from below the flange of the experimental tray located at position D10 on the LDEF. The tray was one of two, comprising the same experiment, the other being located on the wake facing side of the LDEF satellite at position B4. Having access to both trays, we were able to directly compare the effect that orientation with respect to the atomic oxygen flux vector had on the formation of the brown molecular film deposits. The film is thickest on surfaces facing toward the exterior, i.e. the tray corner, as can be seen by comparing the lee and wake aspects of the rivets. The patterns appear to be aligned not with the velocity vector but with the corner of the tray suggesting that flux to the surface is due to scattered atomic oxygen rather than direct ram impingement. The role of scattered flux is further supported by more faint plume patterns on the sides of the tray. The angle of these plumes is strongly aligned with the ram direction but the outline of the deposit implies that incident atoms are scattered by collisions with the edges of the opening resulting in a directed, but diffuse, flux of atomic oxygen to the surface. Spectral reflectance measurements in the 2 to 10 micron (4000 to 1000 wavenumbers) spectral range are presented for the film in the 'as deposited' condition and for the free standing film. The material was analyzed by FTIR (Fourier Transform Infrared) microspectroscopy using gold as the reference standard. The 'as deposited' specimen was on an aluminum rivet taken from beneath the tray flange while the free film was obtained by chipping some of the material from the rivet. The transmission spectrum over the 2 to 10 micron range for the free film is presented. This spectrum appears to be essentially the same as that presented by Crutcher et.al. for films formed at vent sites which faced into the ram direction and suggested to originate from urethanes and silicones used on the LDEF. Banks et. al. state that silicones, when exposed to atomic oxygen, release polymeric scission fragments which deposit on surfaces and form a glassy, dark contaminant layer upon further atomic oxygen exposure and solar irradiation

    LDEF Space Plasma-High Voltage Drainage Experiment post-flight results

    Get PDF
    The Space Plasma-High Voltage Drainage Experiment (SP-HVDE) was comprised of two identical experimental trays. With one tray located on the leading (ram facing, B10) edge and the other located on the trailing (wake facing, D4) edge of the Long Duration Exposure Facility (LDEF), it was possible to directly compare the effects of ram and wake spacecraft environments on charged dielectric materials. Six arrays of Kapton dielectric samples of 2 mil, 3 mil, and 5 mil thicknesses maintained at +/- 300, +/- 500, and +/- 1000 voltage bias formed the experimental matrix of each tray. In addition, each tray carried two solar cell strings, one biased at +300 volts and the other at -300 volts, to study current leakage from High Voltage Solar Arrays (HVSA). The SP-HVDE provides the first direct, long-term, in-flight measurements of average leakage current through dielectric materials under electric stress. The experiment also yields information on the long term stability of the bulk dielectric properties of such materials. Data and findings of the SP-HVDE are an extension of those from shorter term flight experiments such as the PIX-1 (Plasma Interaction Experiment) and PIX-2 and are therefore valuable in the design and evaluation of long-lived space systems with high voltage systems exposed to the low earth orbital environment. A summary of the SP-HVDE post flight analysis final report delivered to the LDEF Project Office under contract to the National Aeronautics and Space Administration is presented

    The On-Orbit Performance of the Galaxy Evolution Explorer

    Full text link
    We report the first year on-orbit performance results for the Galaxy Evolution Explorer (GALEX), a NASA Small Explorer that is performing a survey of the sky in two ultraviolet bands. The instrument comprises a 50 cm diameter modified Ritchey-Chretien telescope with a 1.25 degree field of view, selectable imaging and objective grism spectroscopic modes, and an innovative optical system with a thin-film multilayer dichroic beam splitter that enables simultaneous imaging by a pair of photon counting, microchannel plate, delay line readout detectors. Initial measurements demonstrate that GALEX is performing well, meeting its requirements for resolution, efficiency, astrometry, bandpass definition and survey sensitivity.Comment: This paper will be published as part of the Galaxy Evolution Explorer (GALEX) Astrophysical Journal Letters Special Issu

    Detection of Organic Constituents Including Chloromethylpropene in the Analyses of the ROCKNEST Drift by Sample Analysis at Mars (SAM)

    Get PDF
    key challenge in assessing the habitability of martian environments is the detection of organic matter - a requirement of all life as we know it. The Curiosity rover, which landed on August 6, 2012 in Gale Crater of Mars, includes the Sample Analysis at Mars (SAM) instrument suite capable of in situ analysis of gaseous organic components thermally evolved from sediment samples collected, sieved, and delivered by the MSL rover. On Sol 94, SAM received its first solid sample: scooped sediment from Rocknest that was sieved to <150 m particle size. Multiple 10-40 mg portions of the scoop #5 sample were delivered to SAM for analyses. Prior to their introduction, a blank (empty cup) analysis was performed. This blank served 1) to clean the analytical instrument of SAMinternal materials that accumulated in the gas processing system since integration into the rover, and 2) to characterize the background signatures of SAM. Both the blank and the Rocknest samples showed the presence of hydrocarbon components

    JPL Contamination Control Engineering

    No full text
    JPL has extensive expertise fielding contamination sensitive missions-in house and with our NASA/industry/academic partners.t Development and implementation of performance-driven cleanliness requirements for a wide range missions and payloads - UV-Vis-IR: GALEX, Dawn, Juno, WFPC-II, AIRS, TES, et al - Propulsion, thermal control, robotic sample acquisition systems. Contamination control engineering across the mission life cycle: - System and payload requirements derivation, analysis, and contamination control implementation plans - Hardware Design, Risk trades, Requirements V-V - Assembly, Integration & Test planning and implementation - Launch site operations and launch vehicle/payload integration - Flight ops center dot Personnel on staff have expertise with space materials development and flight experiments. JPL has capabilities and expertise to successfully address contamination issues presented by space and habitable environments. JPL has extensive experience fielding and managing contamination sensitive missions. Excellent working relationship with the aerospace contamination control engineering community/

    Contamination Impact of Station Brush Fire on Cleanroom Facilities

    No full text
    Brush and forest fires, both naturally occurring and anthropogenic in origin, in proximity to space flight hardware processing facilities raise concerns about the threat of contamination resulting from airborne particulate and molecular components of smoke. Perceptions of the severity of the threat are possibly heightened by the high sensitivity of the human sense of smell to some components present in the smoke of burning vegetation.On August 26th, 2009, a brushfire broke out north of Pasadena, California, two miles from the Jet Propulsion Laboratory. The Station Fire destroyed over 160,000 acres, coming within a few hundred yards of JPL. Smoke concentrations on Lab were very heavy over several days. All Lab operations were halted, and measures were taken to protect personnel, critical hardware, and facilities. Evaluation of real-time cleanroom monitoring data, visualinspection of facilities, filter systems, and analysis of surface cleanliness samples revealed facility environments andhardware were minimally effected.Outside air quality easily exceeded Class Ten Million. Prefilters captured most large ash and soot; multi-stage filtration greatly minimized the impact on the HEPA/ULPA filters. Air quality in HEPA filtered spacecraft assembly cleanrooms remained within Class 10,000 specification throughout. Surface cleanliness was inimally affected, as large particles were effectively removed from the airstream, and sub-micron particles have extremely long settling rates. Approximate particulate fallout within facilities was 0.00011% area coverage/day compared to 0.00038% area coverage/day during normal operations. Deposition of condensable airborne components, as measured in real time, peaked at approximately1.0 ng/cm2/day compared to 0.05 ng/cm2/day nominal

    Planning considerations related to the organic contamination of martian samples and implications for the Mars 2020 rover

    Get PDF
    漏 Copyright 2014, Mary Ann Liebert, Inc. Data gathered during recent NASA missions to Mars, particularly by the Rovers Spirit, Opportunity, and Curiosity, have provided important insights into the past history and habitability of the Red Planet. The Mars science community, via input through the National Research Council (NRC) Planetary Science Decadal Survey Committee, also identified the prime importance of a Mars sample return (MSR) mission to further exploration of the Red Planet. In response, the Mars 2020 Mission (Mars 2020) Science Definition Team (SDT) (Mustard et al., 2013) was chartered by the NASA Mars Exploration Program to formulate a new rover mission that would take concrete steps toward an eventual sample return. The SDT recommended that the 2020 rover should select and cache scientifically compelling samples for possible return to Earth. They also noted that organic contamination of the samples was a significant and complex issue that should be independently investigated by a future committee. Accordingly, NASA chartered the Mars 2020 Organic Contamination Panel (OCP). The OCP was charged with evaluating and recommending sample contamination requirements for the proposed Mars 2020. A further task was to assess implementation approaches in support of the investigation of broad scientific questions concerning the history and habitability of Mars. Central to these objectives would be the ability to reliably differentiate indigenous martian organic molecules from terrestrial contamination in any future samples returned from Mars. Early on during its deliberations, the OCP recognized that the scientific and planetary protection (PP) objectives of MSR are intimately linked, in that both rely heavily on measurements of organic molecules in the returned samples. In each case, a key aspect of the problem is being able to recognize and interpret organic molecules as indigenous to Mars against a potential background of Earthsourced contamination. It was within this context that the OCP committee considered the structure for a set of measurement goals related to organic molecules in the returned samples that would be of common interest to science and PP. The following is a summary of the most significant findings of the OCP regarding organic geochemical measurements that would be shared for both science and PP in relation to potential future MSR
    corecore