23 research outputs found

    Detection of non-ST-elevation myocardial infarction and unstable angina in the acute setting: meta-analysis of diagnostic performance of multi-detector computed tomographic angiography

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Multi-detector computed tomography angiography (MDCTA) has been increasingly used in the evaluation of the coronary arteries. The purpose of this study was to review the literature on the diagnostic performance of MDCTA in the acute setting, for the detection of non-ST-elevation myocardial infarction (NSTEMI) and unstable angina pectoris (UAP).</p> <p>Methods</p> <p>A Pubmed and manual search of the literature published between January 2000 and June 2007 was performed. Studies were included that compared MDCTA with clinical outcome and/or CA in patients with acute chest pain, presenting at the emergency department. More specifically, studies that only included patients with initially negative cardiac enzymes suspected of having NSTEMI or UAP were included. Summary estimates of diagnostic odds ratio (DOR), sensitivity and specificity, negative (NLR) and positive likelihood ratio (PLR) were calculated on a patient basis. Random-effects models and summary receiver operating curve (SROC) analysis were used to assess the diagnostic performance of MDCTA with 4 detectors or more. The proportion of non assessable scans (NAP) on MDCTA was also evaluated. In addition, the influence of study characteristics of each study on diagnostic performance and NAP was investigated with multivariable logistic regression.</p> <p>Results</p> <p>Nine studies totalling 566 patients, were included in the meta-analysis: one randomised trial and eight prospective cohort studies. Five studies on 64-detector MDCTA and 4 studies on MDCTA with less than 64 detectors were included (32 detectors n = 1, 16 detectors n = 2, 16 and 4 detectors n = 1). Pooled DOR was 131.81 (95%CI, 50.90–341.31). The pooled sensitivity and specificity were 0.95 (95%CI, 0.90–0.98) and 0.90 (95%CI, 0.87–0.93). The pooled NLR and PLR were 0.12 (95%CI, 0.06–0.21) and 8,60 (95%CI, 5.03–14,69).</p> <p>The results of the logistic regressions showed that none of the investigated variables had influence on the diagnostic performance or NAP</p> <p>Conclusion</p> <p>MDCTA of the coronary arteries performs good to excellent in the diagnosis of coronary artery disease in the acute setting and it can be used for early exclusion of NSTEMI or UAP in patients in the emergency department.</p

    Pengaruh Brand Trust dan Brand Equity terhadap Loyalitas Konsumen pada Produk Kosmetik Wardah (Survey Konsumen pada PT. Paragon Technology And Innovation Cabang Pekanbaru)

    Full text link
    The purpose of this study was to determine the influence of brand trust ( X1 ) and brand equity ( X2 ) customer loyalty ( Y ) in cosmetic products Wardah ( consumer survey on PT . Paragon technology and innovation branches pekanbaru ) . The method in this research is quantitatively using SPSS 21 program , where samples were used that consumers using cosmetic products Wardah by respondents as many as 100 people sampling technique is accidental sampling using the formula slovin . The results showed that the test results simultaneously obtained from the F count was 34.888 while the value of F table 3.090 . This means that F count> F table and significant value 0,000 < alpha of 0.05 . This means that brand trust and brand equity simultaneously significant effect on consumer loyalty to cosmetic products Wardah

    Multidetector computed tomography angiography for assessment of in-stent restenosis: meta-analysis of diagnostic performance

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Multi-detector computed tomography angiography (MDCTA)of the coronary arteries after stenting has been evaluated in multiple studies.</p> <p>The purpose of this study was to perform a structured review and meta-analysis of the diagnostic performance of MDCTA for the detection of in-stent restenosis in the coronary arteries.</p> <p>Methods</p> <p>A Pubmed and manual search of the literature on in-stent restenosis (ISR) detected on MDCTA compared with conventional coronary angiography (CA) was performed. Bivariate summary receiver operating curve (SROC) analysis, with calculation of summary estimates was done on a stent and patient basis. In addition, the influence of study characteristics on diagnostic performance and number of non-assessable segments (NAP) was investigated with logistic meta-regression.</p> <p>Results</p> <p>Fourteen studies were included. On a stent basis, Pooled sensitivity and specificity were 0.82(0.72–0.89) and 0.91 (0.83–0.96). Pooled negative likelihood ratio and positive likelihood ratio were 0.20 (0.13–0.32) and 9.34 (4.68–18.62) respectively. The exclusion of non-assessable stents and the strut thickness of the stents had an influence on the diagnostic performance. The proportion of non-assessable stents was influenced by the number of detectors, stent diameter, strut thickness and the use of an edge-enhancing kernel.</p> <p>Conclusion</p> <p>The sensitivity of MDTCA for the detection of in-stent stenosis is insufficient to use this test to select patients for further invasive testing as with this strategy around 20% of the patients with in-stent stenosis would be missed. Further improvement of scanner technology is needed before it can be recommended as a triage instrument in practice. In addition, the number of non-assessable stents is also high.</p

    Relationship between mold exposure, specific IgE sensitization, and clinical asthma: A case-control study.

    No full text
    Most of the findings related to the noxious effect of mold sensitization on asthma come from investigations based on Alternaria alternata, Cladosporium herbarum, and Aspergillus fumigatus. However, species such as Penicillium spp, Cladosporium sphaerospermum, Cladosporium cladosporioides, or Aspergillus versicolor display a more pronounced indoor tropism, and their potential harmful respiratory effects cannot be neglected.SCOPUS: ar.jinfo:eu-repo/semantics/publishe

    Clinical impact of CT coronary angiography without exclusion of small coronary artery segments: a real-world and long-term study

    No full text
    Objectives CT coronary angiography (CTCA) has become a valuable diagnostic test in the workup of patients with possible coronary artery disease (CAD). Because of inherent limitations in spatial resolution, epicardial vessels with a small diameter, in general less than 1.5-2 mm, have so far been excluded in studies assessing clinical utility of CTCA. This study sought to assess the clinical impact of CTCA taking into account pathology in small coronary arteries. Methods We conducted a retrospective cohort study of all patients with possible CAD who underwent dual-source CTCA and subsequent invasive coronary angiography (ICA) between January 2010 and July 2017. Patients with an Agatston calcium score >= 1000 were reported separately. Diagnostic accuracy of CTCA on a patient, vessel and segment level was calculated. The physician's therapeutic decision was defined as conservative, medical antianginal treatment or revascularisation. Using ICA as the reference, we calculated the precision of CTCA to replicate these therapeutic recommendations. Results In total, 1209 patients underwent both CTCA and ICA. Overall diagnostic performance of CTCA showed a sensitivity of 90% (95% CI 86% to 93%) and specificity of 40% (95% CI 36% to 45%). With regard to clinical decision making, CTCA showed good performance: 91% of patients who were treated medically or by revascularisation were correctly identified. Prevalence of disease in small vessel segments was low: 16% showed significant CAD on ICA. Prevalence of significant disease was 70% in patients with an Agatston score >= 1000: the majority underwent revascularisation. Conclusions From a true patient perspective, without exclusion of smaller coronary artery segments, CTCA allows safe patient management

    Clinical impact of CT coronary angiography without exclusion of small coronary artery segments : a real-world and long-term study

    No full text
    Objectives CT coronary angiography (CTCA) has become a valuable diagnostic test in the workup of patients with possible coronary artery disease (CAD). Because of inherent limitations in spatial resolution, epicardial vessels with a small diameter, in general less than 1.5-2 mm, have so far been excluded in studies assessing clinical utility of CTCA. This study sought to assess the clinical impact of CTCA taking into account pathology in small coronary arteries. Methods We conducted a retrospective cohort study of all patients with possible CAD who underwent dual-source CTCA and subsequent invasive coronary angiography (ICA) between January 2010 and July 2017. Patients with an Agatston calcium score >= 1000 were reported separately. Diagnostic accuracy of CTCA on a patient, vessel and segment level was calculated. The physician's therapeutic decision was defined as conservative, medical antianginal treatment or revascularisation. Using ICA as the reference, we calculated the precision of CTCA to replicate these therapeutic recommendations. Results In total, 1209 patients underwent both CTCA and ICA. Overall diagnostic performance of CTCA showed a sensitivity of 90% (95% CI 86% to 93%) and specificity of 40% (95% CI 36% to 45%). With regard to clinical decision making, CTCA showed good performance: 91% of patients who were treated medically or by revascularisation were correctly identified. Prevalence of disease in small vessel segments was low: 16% showed significant CAD on ICA. Prevalence of significant disease was 70% in patients with an Agatston score >= 1000: the majority underwent revascularisation. Conclusions From a true patient perspective, without exclusion of smaller coronary artery segments, CTCA allows safe patient management

    Pro-thrombotic effect of exercise in a polluted environment: A P-selectin-and CD63-related platelet activation effect

    No full text
    Exposure to diesel exhaust is an important cardiovascular risk factor and may promote atherothrombotic events. Some data suggest that polluted air exposure could affect haemostasis through platelet activation. The aim of the study was to investigate the effects of acute exposure to diesel exhaust on platelet activation and platelet function. We tested the hypothesis in a randomised, crossover study in 25 healthy men exposed to ambient and polluted air; 11 of the subjects also performed exercise during exposure sessions. Platelet activation was evaluated by surface expression of CD62P (P-selectin) and CD63 (dense granule glycoprotein) using flow cytometry of labelled platelets. Platelet function was measured using the PFA-100 platelet function analyser and by Multiplate whole blood impedance platelet aggregometry. Acute diesel exhaust exposure had no effect on platelet activation at rest, but exercise in polluted air increased the collagen-induced expression of CD62P and CD63 (both p< 0.05). The increase in the expression of CD62P and CD63 was related to the total amount of PM2.5 inhaled during the exercise sessions (r=+0.58 and +0.60, respectively, both p< 0.05). Platelet aggregation was not impaired after polluted air exposure at rest or during exercise. In conclusion, in healthy subjects, diesel exhaust exposure induces platelet activation as illustrated by a dose-response increase in the release of CD62P and CD63. This platelet priming effect could be a contributor to the triggering of atherothrombotic events related to air pollution exposure.SCOPUS: ar.jinfo:eu-repo/semantics/publishe
    corecore