    Low kilovoltage cardiac dual-source CT: attenuation, noise, and radiation dose

    Get PDF
    The purpose of this study was to investigate the effect of low kilovoltage dual-source computed tomography coronary angiography (CTCA) on qualitative and quantitative image quality parameters and radiation dose. Dual-source CTCA with retrospective ECG gating was performed in 80 consecutive patients of normal weight. Forty were examined with a standard protocol (120kV/330mAs), 20 were examined at 100kV/330mAs, and 20 at 100kV/220mAs. Two blinded observers independently assessed image quality of each coronary segment and measured the image parameters noise, attenuation, and contrast-to-noise ratio (CNR). The effective radiation dose was calculated using CT dose volume index and the dose-length product. Diagnostic image quality was obtained in 99% of all coronary segments (1,127/1,140) without significant differences among the protocols. Image noise, attenuation, and CNR were significantly higher for 100kV/330mAs (26 ± 3HU, 549 ± 62HU, 25.5 ± 3.2; each P < 0.01) and 100kV/220mAs (27 ± 2HU, 560 ± 43HU, 25.0 ± 2.2; each P < 0.01) when compared to the 120-kV protocol (21 ± 2HU, 317 ± 28HU, 20.6 ± 1.7). There was no significant difference between the two 100-kV protocols. Estimated effective radiation dose of the 120-kV protocol (8.9 ± 1.2mSv) was significantly higher than the 100kV/330mAs (6.7 ± 0.8mSv, P < 0.01) or 100kV/220mAs (4.4 ± 0.6mSv, P < 0.001) protocols. Dual-source CTCA with 100kV is feasible in patients of normal weight, results in a diagnostic image quality with a higher CNR, and at the same time significantly reduces the radiation dos

    Low kilovoltage cardiac dual-source CT: attenuation, noise, and radiation dose

    Full text link
    The purpose of this study was to investigate the effect of low kilovoltage dual-source computed tomography coronary angiography (CTCA) on qualitative and quantitative image quality parameters and radiation dose. Dual-source CTCA with retrospective ECG gating was performed in 80 consecutive patients of normal weight. Forty were examined with a standard protocol (120 kV/330mAs), 20 were examined at 100 kV/330mAs, and 20 at 100 kV/220mAs. Two blinded observers independently assessed image quality of each coronary segment and measured the image parameters noise, attenuation, and contrast-to-noise ratio (CNR). The effective radiation dose was calculated using CT dose volume index and the dose-length product. Diagnostic image quality was obtained in 99% of all coronary segments (1,127/1,140) without significant differences among the protocols. Image noise, attenuation, and CNR were significantly higher for 100 kV/330mAs (26 +/- 3 HU, 549 +/- 62 HU, 25.5 +/- 3.2; each P < 0.01) and 100 kV/220mAs (27 +/- 2 HU, 560 +/- 43 HU, 25.0 +/- 2.2; each P < 0.01) when compared to the 120-kV protocol (21 +/- 2 HU, 317 +/- 28 HU, 20.6 +/- 1.7). There was no significant difference between the two 100-kV protocols. Estimated effective radiation dose of the 120-kV protocol (8.9 +/- 1.2 mSv) was significantly higher than the 100 kV/330mAs (6.7 +/- 0.8 mSv, P < 0.01) or 100 kV/220mAs (4.4 +/- 0.6 mSv, P < 0.001) protocols. Dual-source CTCA with 100 kV is feasible in patients of normal weight, results in a diagnostic image quality with a higher CNR, and at the same time significantly reduces the radiation dose
    corecore