119 research outputs found

    Comparison of the cobas 4800 CT/NG test with culture for detecting neisseria gonorrhoeae in genital and nongenital specimens in a low-prevalence population in New Zealand

    Get PDF
    To assess the clinical utility of replacing microbial culture for Neisseria gonorrhoeae with a nucleic acid amplification test (NAAT), we compared N. gonorrhoeae culture with the cobas 4800 CT/NG test for 18,247 urogenital and 666 nongenital samples. For urogenital specimens, the sensitivity, specificity, and positive and negative predictive values of the cobas N. gonorrhoeae PCR were 98.7%, 100%, 95.6%, and 100%, respectively, and for nongenital specimens, the values were 100%, 99.8%, 92.9%, and 100%, respectively. In our test population, 37% (10,185) of patients tested over the study period were screened for C. trachomatis by PCR but were not screened for gonorrhea by culture. Of these, 43 were N. gonorrhoeae positive by PCR and therefore went undiagnosed. The cobas 4800 CT/NG test diagnosed 33% (n=30) more urogenital and 25% (n=3) more rectal gonorrhea infections than culture and, based on the above performance indicators, does not require supplementary testing for urogenital or rectal specimens. The ability to test noninvasive specimens (such as urine and self-taken vulvovaginal swabs) for N. gonorrhoeae will enable more patients to be screened for infection, thus offering significant positive public health benefits. Copyrigh

    Incidence of Hepatitis-C among HIV infected men who have sex with men (MSM) attending a sexual health service: a cohort study

    Get PDF
    BACKGROUND: We aimed to determine the incidence of Hepatitis C (HCV) infection among HIV-infected men who have sex with men (MSM) attending a Sexual Health Centre. METHODS: A retrospective cohort study was carried out among HIV-infected MSM seen at least once between February 2002 and March 2010. The analysis was restricted to MSM who had had a negative HCV antibody test at least 6 months after their diagnosis for HIV. Duration of follow up was taken from the date of HIV diagnosis to the first positive or last negative HCV antibody test. RESULTS: During the time 1445 HIV-infected men attended the clinic of whom 1065 (74%) were MSM. Of these, 869 (82%) were tested for HCV at any time after HIV diagnosis. Of these 869, 69% (620) tested HCV negative at least 6 months after their HIV diagnosis. These 620 men had a mean age of 34 years (range 17-72) at HIV diagnosis and a total of 4,359 person years (PY) of follow up. There were 40 incident cases of HCV, of which 16 were in injecting drug users (IDU) and 24 in non-IDU. The overall incidence of HCV among HIV-infected MSM was 0.9/100 PY (95% CI 0.6-1.2). The incidence among HIV-infected IDU was 4.7/100 PY (95% CI 2.7-7.5) while the incidence among HIV-infected non-IDU was 0.6/100 PY (95% CI 0.4-0.8) (hazard ratio of 8.7 and 95% CI 4.6-16.6, P < 0.001).The majority (78%) were tested for HCV because they developed abnormal liver transaminases (n = 31) or hepatitis symptoms (n = 2), while others (n = 7) were identified through routine HCV testing. CONCLUSION: A considerable proportion of HIV-positive MSM who did not inject drugs contracted HCV, presumably via sexual transmission and the main trigger for investigation was abnormal liver transaminases

    Viral, bacterial, and fungal infections of the oral mucosa:Types, incidence, predisposing factors, diagnostic algorithms, and management

    Get PDF

    Current perspectives in percutaneous atrial septal defect closure devices

    No full text
    N Bissessor1&ndash;4 1Department of Cardiology, The Epworth Hospital, Melbourne, VIC, Australia; 2Division of Interventional Cardiology, The Alfred Hospital, Melbourne, VIC, Australia; 3Department of Clinical Science, Charles Sturt University Albury Campus, NSW, Australia; 4Heart Foundation, Griffith University, QLD, Australia Abstract: In the last decade, percutaneous atrial septal defect (ASD) closure has become the treatment of choice in most clinical presentations of ASD. Percutaneous ASD closure has established procedural safety through operator experience and improved device structure and deliverability. There have also been advances in diagnostic capabilities. Devices have evolved from large bulky meshes to repositionable, minimal residual mesh content that easily endothelializes and conforms well to surrounding structures. Biodegradable technology has been introduced and will be closely watched as a future option. The evolution of ASD closure device usage in the last four decades incorporates development that minimizes a wide range of serious side effects that have been reported over the years. Complications reported in the literature include thrombus formation, air embolization, device embolization, erosions, residual shunts, and nickel hypersensitivity. Modern devices have intermediate to long term data with outcomes that have been favorable. Devices are available in multiple sizes with improved delivery mechanisms to recapture, reposition, and safely close simple and complex ASDs amenable to percutaneous closure. In this review, commonly used devices and deployment procedures are discussed together with a look at devices that show promise for the future. Keywords: ASD, congenital, Amplatzer, Gore Helex, Biostar, Figull

    Advances in clinical testing for sexually transmitted infections

    No full text
    © 2015 Dr. Melanie BissessorThis thesis comprises six separate projects that focus on advancing in clinical testing for sexually transmitted infections: i) The aetiology of proctitis according to HIV status in men who have sex with men; ii) The contribution of Mycoplasma genitalium to the aetiology of proctitis in men who have sex with men; iii) Persistence of Neisseria gonorrhoeae DNA following treatment for pharyngeal and rectal gonorrhoea; iv) Detection of Neisseria gonorrhoeae from the tonsils and posterior pharynx; v) Macrolide resistance and azithromycin failure in a Mycoplasma genitalium-infected cohort, and response of azithromycin failures to alternative antibiotic regimens; vi) Provision of HIV test results by telephone is safe and effective for men who have sex with me

    Valsartan in the treatment of heart failure or left ventricular dysfunction after myocardial infarction

    No full text
    Naylin Bissessor1, Harvey White21Cardiology Research Fellow, 2Director of Coronary Care and Green Lane, Cardiovascular Research Unit, Green Lane Cardiovascular Research Unit, Auckland City Hospital, Auckland, New ZealandAbstract: The physiological role of the renin angiotensin aldosterone system (RAAS) is to maintain the integrity of the cardiovascular system. The effect of angiotensin II is mediated via the angiotensin type I receptor (AT1) resulting in vasoconstriction, sodium retention and myocyte growth changes. This causes myocardial remodeling which eventually leads to left ventricular hypertrophy, dilation and dysfunction. Inhibition of the RAAS with angiotensin converting enzyme (ACE) inhibitors after acute myocardial infarction has been shown to reduce cardiovascular morbidity and mortality. Angiotensin receptor blockers (ARBs) specifically inhibit the AT1 receptor. It has not been known until the performance of the VALIANT (valsartan in acute myocardial infarction trial) whether blockade of the angiotensin receptor with an ARB or combination of an ACE inhibitor and ARB leads to similar outcomes as an ACE inhibitor. The VALIANT trial demonstrated equal efficacy and non-inferiority of the ARB valsartan 160 mg bid compared with captopril 50 mg tds, when administered to high risk patients with left ventricular dysfunction or heart failure in the immediate post myocardial infarction period. The combination therapy showed no incremental benefit over ACE inhibition or an ARB alone and resulted in increased adverse effects. This review examines the role of valsartan in left ventricular dysfunction post myocardial infarction. We also discuss pharmacokinetics, dosing, side effects, and usage in the elderly.Keywords: valsartan, heart failure, left ventricular dysfunction, myocardial infarctio
    • 

    corecore