688 research outputs found

    Predicting the microbial exposure risks in urban floods using GIS, building simulation, and microbial models

    Get PDF
    London is expected to experience more frequent periods of intense rainfall and tidal surges, leading to an increase in the risk of flooding. Damp and flooded dwellings can support microbial growth, including mould, bacteria, and protozoa, as well as persistence of flood-borne microorganisms. The amount of time flooded dwellings remain damp will depend on the duration and height of the flood, the contents of the flood water, the drying conditions, and the building construction, leading to particular properties and property types being prone to lingering damp and human pathogen growth or persistence. The impact of flooding on buildings can be simulated using Heat Air and Moisture (HAM) models of varying complexity in order to understand how water can be absorbed and dry out of the building structure. This paper describes the simulation of the drying of building archetypes representative of the English building stock using the EnergyPlus based tool ‘UCL-HAMT’ in order to determine the drying rates of different abandoned structures flooded to different heights and during different seasons. The results are mapped out using GIS in order to estimate the spatial risk across London in terms of comparative flood vulnerability, as well as for specific flood events. Areas of South and East London were found to be particularly vulnerable to long-term microbial exposure following major flood events

    The thermal characteristics of roofs: policy, installation and performance

    Get PDF
    This paper investigates the in-situ performance of UK cold pitched roof structures through a case study dwelling of typical construction using site survey, and estimation of U-values through simple calculation and from measured heat flow data. Significant increases of U-values resulted from under- and un-insulated areas due to installation issues, whilst a higher than expected estimated thermal resistance of the roof space and structure was also noted, potentially associated with heat gains. Both issues are expected to be observed more widely in the stock and contribute to a performance gap for roof insulation

    Simulation of pollution transport in buildings: the importance of taking into account dynamic thermal effects

    Get PDF
    The recent introduction of the Generic Contaminant Model in EnergyPlus allows for the integrated modelling of multizone contaminant and dynamic thermal behaviour within a single simulation package. This article demonstrates how dynamic thermal simulation can modify pollutant transport within a building. PM2.5 infiltration from the external to internal environment under dynamic thermal conditions is compared in CONTAM, EnergyPlus 8.0, and Polluto, an in-house pollutant transport model developed in EnergyPlus 3.1. The influence of internal temperature on indoor PM2.5 levels is investigated by comparing results from standard CONTAM simulations and dynamic thermal EnergyPlus 8 simulations. Circumstances where the predictions of such models can diverge are identified

    How solid is our knowledge of solid walls? - Comparing energy savings through three different methods

    Get PDF
    Recent UK-based studies have shown a performance gap between the energy performance of buildings calculated using tabulated thermophysical properties of solid walls and that estimated from in-situ measurements. Solid-walled buildings have been targeted by UK Government policies and incentive schemes to meet climate change mitigation targets and improve the efficiency of the building stock, as they are less efficient and more expensive to treat than cavity walls. Since it is common practice to estimate energy use and potential savings for buildings retrofit assuming standard values from the literature, the performance gap may have serious implications on the decision-making and the cost-effectiveness of energy-saving interventions. The aim of this paper is to compare and contrast the results obtained from three different methods for estimating normalised dwelling energy demand: a) the UK energy performance certificate (EPC) method, which uses the standard assessment procedure (SAP) with tabulated inputs (the business as usual case); b) the SAP calculated using empirical air change rates from pressure tests and U-values estimated analysing monitored data with a Bayesian-based dynamic method developed by the authors; c) a normalised annual consumption (NAC) method based on empirical energy consumption data from smart meter and weather data. The analysis is performed on a sample of dwellings from the Energy Saving Trust “Solid Wall Field Trials” dataset. Results show that EPC estimates are systematically higher (between 7.5% and 22.0%) than SAP. Conversely, the NAC displayed a large range of relative differences (between -77% and +99%) compared to the EPC. This raises questions about the relative merits and purpose of the EPC and SAP bottom up methods compared to the smart-meter data-driven NAC method. Further research is suggested using SAP 2009 to isolate the thermal component of energy demand and compare it directly with the NAC component

    Using building simulation to model the drying of flooded building archetypes

    Get PDF
    With a changing climate, London is expected to experience more frequent periods of intense rainfall and tidal surges, leading to an increase in the risk of flooding. This paper describes the simulation of the drying of flooded building archetypes representative of the London building stock using the EnergyPlus-based hygrothermal tool ‘University College London-Heat and Moisture Transfer (UCL-HAMT)’ in order to determine the relative drying rates of different built forms and envelope designs. Three different internal drying scenarios, representative of conditions where no professional remediation equipment is used, are simulated. A mould model is used to predict the duration of mould growth risk following a flood on the internal surfaces of the different building types. Heating properties while keeping windows open dried dwellings fastest, while purpose built flats and buildings with insulated cavity walls were found to dry slowest

    ‘Hitting the target and missing the point’: Analysis of air permeability data for new UK dwellings and what it reveals about the testing procedure

    Get PDF
    Airtightness testing is widely undertaken to assess the as-built performance of dwellings, in support of achieving energy and ventilation strategies. Mandatory schemes operate in some countries, such as the UK, to ensure that dwellings are built in accordance with their design air permeability. However, testing is only useful if the results give a true picture of the airtightness of the building. Previous literature has investigated factors which could influence airtightness test results but has not questioned data quality, despite the pressure on builders to achieve design targets. This paper presents air permeability results from the largest UK dataset, comprising 144,024 dwellings tested under the Air Tightness Testing and Measurement Association (ATTMA) scheme. The data show an unexpected distribution of test results with narrow peaks just within test targets. Such results were not expected theoretically but do reflect findings in other fields where performance-based targets are in place. Such a close match between design and tested airtightness may be achieved by remedial works taking place during the test rather than afterwards. Recommendations are made with respect to quality assurance systems, design guidance and on-site sealing practices to increase the likelihood of long-term airtight buildings being constructed first time

    Cohort Profile: The Health Survey for England

    Get PDF
    To monitor the health of the public in England, UK, the Central Health Monitoring Unit within the UK Department of Health commissioned an annual health examination survey, which became known as the Health Survey for England (HSE). The first survey was completed in 1991. The HSE covers all of England and is a nationally representative sample of those residing at private residential addresses. Each survey year consists of a new sample of private residential addresses and people. The HSE collects detailed information on mental and physical health, health-related behaviour, and objective physical and biological measures in relation to demographic and socio-economic characteristics of people aged 16 years and over at private residential addresses. There are two parts to the HSE; an interviewer visit, to conduct an interview and measure height and weight, then a nurse visit, to carry out further measurements and take biological samples. Since 1994, survey participants aged 16 years and over have been asked for consent to follow-up through linkage to mortality and cancer registration data, and from 2003, to the Hospital Episode Statistics database, thus converting annual cross-sectional survey data into a longitudinal study. Annual survey data (1994–2009) are available through the UK Data Archive

    Housing as a modifier of air contaminant and temperature exposure in Great Britain: A modelling framework

    Get PDF
    This paper presents the development of a modelling framework that quantifies the modifying effect of dwelling characteristics on exposure to indoor air pollution and excess temperature. A georeferenced domestic building stock model of Great Britain was created using national housing surveys, historical weather, and local terrain data. Dynamic building performance simulation was applied to estimate indoor air pollution and overheating risk metrics at the individual building level. These metrics were then aggregated at various geographic units and mapped across Britain within a Geographic Information System (GIS) environment to compare spatial trends. Results indicate that flats and newly built properties are characterised by lower indoor air pollution from outdoor sources, but higher air pollution from indoor sources. Flats, bungalows and newly built, more airtight dwellings are found to be more prone to overheating. Consequently, urban populations may experience higher levels of pollution from indoor sources and overheating resulting from the higher prevalence of flats in cities

    The Absorption and Translocation of Iron

    Full text link
    corecore