710 research outputs found

    TOWARDS A PROCESS-ORIENTED APPROACH TO ASSESSING, CLASSIFYING AND VISUALIZING ENTERPRISE CONTENT WITH DOCUMENT MAPS

    Get PDF
    Nowadays, documents can be scattered across a company in different versions, formats, and languages, and even on different systems. Not only is the resulting content chaos inefficient, it brings with it a number of risks. However, information that is contained in unstructured documents is increasingly becoming a key business resource. Enterprise content management (ECM) is used to manage unstructured content on an enterprise-wide scale. Despite the practical importance of ECM, research is still at an immature state and the process perspective is widely neglected. We suggest a process-oriented approach to identifying, assessing, documenting, classifying and visualizing enterprise content. Within a globally operating engineering company, we check to what extent the applicability of the designed research artifact can be assumed. We give process-oriented guidelines to identify and document enterprise content. Our 7W Framework (7WF) for content assessment contains a collection of metadata (attributes, typical attribute values) to create customized content surveys. Different visual representations of content are proposed, including a document map. Combining business processes and the content of an enterprise, the document map is able to integrate the ECM perspectives and provides decision support. Technical requirements can be derived from it and in-depth analysis of business-critical content is enabled

    ALLOREACTIVE T LYMPHOCYTES CULTURED FROM LIVER TRANSPLANT BIOPSIES: ASSOCIATIONS OF HLA SPECIFICITY WITH CLINICOPATHOLOGICAL FINDINGS.

    Get PDF
    Lymphocyte cultures grown from liver allograft biopsies were shown to exhibit alloreactivity towards donor cells as measured by primed lymphocyte testing (PLT). The PLT specificity was determined in assays using HLA typed panel cells and/or by inhibition testing with HLA specific monoclonal antibodies. Certain cultures exhibited PLT specificity towards class I HLA antigens of the donor, whereas others were specific for class II HLA antigens or recognized mixtures of class I and II antigens. These PLT specificity patterns were compared with clinical, histological and laboratory findings on the liver transplant patients at the time of the biopsy. Biopsies yielding class I specific PLT cells were taken generally during the earlier posttransplant period, whereas class II specific cells were grown from later biopsies. There was no significant correlation of the PLT specificity towards class I vs II antigens with the levels of total or direct bilirubin, serum glutamate oxaloacetic transaminase (SGOT), and serum glutamate pyruvate transaminase (SGPT), although a trend towards higher values was noted for biopsies presenting with a class II specific infiltrate. However, the levels of gamma glutamyl transpeptidase (GGTP) and alkaline phosphatase (AP) were significantly increased when biopsies yielded class II specific rather than class I specific PLT cells. Biopsy histology showed more damage to bile duct epithelium in association with class II PLT specificity whereas intense but often reversible infiltrates were found in biopsies yielding class I specific cells. The elevated GGTP and AP levels are probably related to the interaction of class II specific T cells with bile duct epithelium, which has been shown to express induced class II HLA antigens on their cell surface

    Multiparametric ultrasound findings in acute kidney failure due to rare renal cortical necrosis

    Get PDF
    Renal cortical necrosis (RCN) is a rare cause of acute kidney failure and is usually diagnosed on the basis of characteristic enhancement patterns on cross-sectional imaging. Contrast-enhanced ultrasound (CEUS) offers benefits in patients with kidney failure in the clinical setting including the use of a nonnephrotoxic intravascular contrast agent and the fact that it can be performed at the bedside in critical cases. Therefore, the aim of this study is to investigate whether CEUS can reliably identify typical imaging features of RCN. We retrospectively analyzed 12 patients with RCN examined in our department and confirmation of the diagnosis by either histopathology, other contrast-enhanced cross-sectional imaging tests, and/or CEUS follow-up. Assessed parameters in conventional US were reduced echogenicity, loss of corticomedullary differentiation, length and width of kidney, hypoechoic rim, resistance index and in CEUS delayed wash-in of contrast agent (>20 s), reverse rim sign, maximum nonenhancing rim and additional renal infarction. Furthermore, imaging features in RCN were compared with the findings in renal vein thrombosis (RVT), among them echogenicity, corticomedullar differentiation, hypoechoic rim, RI value, delayed cortical enhancement, total loss of cortical perfusion and enhancement of renal medulla. All 12 patients showed the reverse rim sign, while a hypoechogenic subcapsular rim was only visible in four patients on B-mode ultrasound. A resistance index (RI) was available in 10 cases and was always less than 1. RI was a strong differentiator in separating RVT from RCN (RI>1 or not measurable due to hypoperfusion as differentiator, p=0.001). CEUS showed total loss of medullary enhancement in all cases of RVT. With its higher temporal resolution, CEUS allows dynamic assessment of renal macro- and microcirculation and identification of the typical imaging findings of RCN with use of a nonnephrotoxic contrast agent

    Graphene: Piecing it together

    Get PDF
    Graphene has a multitude of striking properties that make it an exceedingly attractive material for various applications, many of which will emerge over the next decade. However, one of the most promising applications lie in exploiting its peculiar electronic properties which are governed by its electrons obeying a linear dispersion relation. This leads to the observation of half integer quantum hall effect and the absence of localization. The latter is attractive for graphene-based field effect transistors. However, if graphene is to be the material for future electronics, then significant hurdles need to be surmounted, namely, it needs to be mass produced in an economically viable manner and be of high crystalline quality with no or virtually no defects or grains boundaries. Moreover, it will need to be processable with atomic precision. Hence, the future of graphene as a material for electronic based devices will depend heavily on our ability to piece graphene together as a single crystal and define its edges with atomic precision. In this progress report, the properties of graphene that make it so attractive as a material for electronics is introduced to the reader. The focus then centers on current synthesis strategies for graphene and their weaknesses in terms of electronics applications are highlighted.Comment: Advanced Materials (2011

    ReGTime - rent gigaflops sometimes

    Get PDF

    Information security awareness and behavior: A theory-based literature review

    Get PDF
    Purpose – This paper aims to provide an overview of theories used in the field of employees’ information systems (IS) security behavior over the past decade. Research gaps and implications for future research are worked out by analyzing and synthesizing existing literature. Design/methodology/approach – This paper presents the results of a literature review comprising 113 publications. The literature review was designed to identify applied theories and to understand the cognitive determinants in the research field. A meta-model that explains employees’ IS security behavior is introduced by assembling the core constructs of the used theories. Findings – The paper identified 54 used theories, but four behavioral theories were primarily used: Theory of Planned Behavior (TPB), General Deterrence Theory (GDT), Protection Motivation Theory (PMT) and Technology Acceptance Model (TAM). By synthesizing results of empirically tested research models, a survey of factors proven to have a significant influence on employees’ security behavior is presented. Research limitations/implications – Some relevant publications might be missing within this literature review due to the selection of search terms and/or databases. However, by conduction a forward and a backward search, this paper has limited this error source to a minimum. Practical implications – This study presents an overview of determinants that have been proven to influence employees’ behavioral intention. Based thereon, concrete training and awareness measures can be developed. This is valuable for practitioners in the process of designing Security Education, Training and Awareness (SETA) programs. Originality/value – This paper presents a comprehensive up-to-date overview of existing academic literature in the field of employees’ security awareness and behavior research. Based on a developed meta-model, research gaps are identified and implications for future research are worked out. © Emerald Group Publishing Limited

    Infections with Avian Pathogenic and Fecal Escherichia coli Strains Display Similar Lung Histopathology and Macrophage Apoptosis

    Get PDF
    The purpose of this study was to compare histopathological changes in the lungs of chickens infected with avian pathogenic (APEC) and avian fecal (Afecal) Escherichia coli strains, and to analyze how the interaction of the bacteria with avian macrophages relates to the outcome of the infection. Chickens were infected intratracheally with three APEC strains, MT78, IMT5155, and UEL17, and one non-pathogenic Afecal strain, IMT5104. The pathogenicity of the strains was assessed by isolating bacteria from lungs, kidneys, and spleens at 24 h post-infection (p.i.). Lungs were examined for histopathological changes at 12, 18, and 24 h p.i. Serial lung sections were stained with hematoxylin and eosin (HE), terminal deoxynucleotidyl dUTP nick end labeling (TUNEL) for detection of apoptotic cells, and an anti-O2 antibody for detection of MT78 and IMT5155. UEL17 and IMT5104 did not cause systemic infections and the extents of lung colonization were two orders of magnitude lower than for the septicemic strains MT78 and IMT5155, yet all four strains caused the same extent of inflammation in the lungs. The inflammation was localized; there were some congested areas next to unaffected areas. Only the inflamed regions became labeled with anti-O2 antibody. TUNEL labeling revealed the presence of apoptotic cells at 12 h p.i in the inflamed regions only, and before any necrotic foci could be seen. The TUNEL-positive cells were very likely dying heterophils, as evidenced by the purulent inflammation. Some of the dying cells observed in avian lungs in situ may also be macrophages, since all four avian E. coli induced caspase 3/7 activation in monolayers of HD11 avian macrophages. In summary, both pathogenic and non-pathogenic fecal strains of avian E. coli produce focal infections in the avian lung, and these are accompanied by inflammation and cell death in the infected areas

    Point-of-care lung ultrasound in COVID-19 patients: inter- and intra-observer agreement in a prospective observational study

    Get PDF
    With an urgent need for bedside imaging of coronavirus disease 2019 (COVID-19), this study's main goal was to assess inter- and intraobserver agreement in lung ultrasound (LUS) of COVID-19 patients. In this single-center study we prospectively acquired and evaluated 100 recorded ten-second cine-loops in confirmed COVID-19 intensive care unit (ICU) patients. All loops were rated by ten observers with different subspeciality backgrounds for four times by each observer (400 loops overall) in a random sequence using a web-based rating tool. We analyzed inter- and intraobserver variability for specific pathologies and a semiquantitative LUS score. Interobserver agreement for both, identification of specific pathologies and assignment of LUS scores was fair to moderate (e.g., LUS score 1 Fleiss' kappa =0.27; subpleural consolidations Fleiss' kappa =0.59). Intraobserver agreement was mostly moderate to substantial with generally higher agreement for more distinct findings (e.g., lowest LUS score 0 vs. highest LUS score 3 (median Fleiss' kappa =0.71 vs. 0.79) or air bronchograms (median Fleiss' kappa =0.72)). Intraobserver consistency was relatively low for intermediate LUS scores (e.g. LUS Score 1 median Fleiss' kappa =0.52). We therefore conclude that more distinct LUS findings (e.g., air bronchograms, subpleural consolidations) may be more suitable for disease monitoring, especially with more than one investigator and that training material used for LUS in point-of-care ultrasound (POCUS) should pay refined attention to areas such as B-line quantification and differentiation of intermediate LUS scores
    • …
    corecore