26 research outputs found

    High rate, fast timing Glass RPC for the high {\eta} CMS muon detectors

    Full text link
    The HL-LHC phase is designed to increase by an order of magnitude the amount of data to be collected by the LHC experiments. To achieve this goal in a reasonable time scale the instantaneous luminosity would also increase by an order of magnitude up to 6.1034cm2s16.10^{34} cm^{-2} s^{-1} . The region of the forward muon spectrometer (η>1.6|{\eta}| > 1.6) is not equipped with RPC stations. The increase of the expected particles rate up to 2kHz/cm22 kHz/cm^{2} (including a safety factor 3) motivates the installation of RPC chambers to guarantee redundancy with the CSC chambers already present. The actual RPC technology of CMS cannot sustain the expected background level. The new technology that will be chosen should have a high rate capability and provides a good spatial and timing resolution. A new generation of Glass-RPC (GRPC) using low-resistivity (LR) glass is proposed to equip at least the two most far away of the four high η{\eta} muon stations of CMS. First the design of small size prototypes and studies of their performance in high-rate particles flux is presented. Then the proposed designs for large size chambers and their fast-timing electronic readout are examined and preliminary results are provided.Comment: 14 pages, 11 figures, Conference proceeding for the 2016 Resistive Plate Chambers and Related Detector

    Performance of Resistive Plate Chambers installed during the first long shutdown of the CMS experiment

    Full text link
    The CMS experiment, located at the CERN Large Hadron Collider, has a redundant muon system composed by three different detector technologies: Cathode Strip Chambers (in the forward regions), Drift Tubes (in the central region) and Resistive Plate Chambers (both its central and forward regions). All three are used for muon reconstruction and triggering. During the first long shutdown (LS1) of the LHC (2013-2014) the CMS muon system has been upgraded with 144 newly installed RPCs on the forth forward stations. The new chambers ensure and enhance the muon trigger efficiency in the high luminosity conditions of the LHC Run2. The chambers have been successfully installed and commissioned. The system has been run successfully and experimental data has been collected and analyzed. The performance results of the newly installed RPCs will be presented.Comment: 5 pages, 6 figures, proceeding to The XIII workshop on Resistive Plate Chambers and Related Detectors (RPC2016

    RPC upgrade project for CMS Phase II

    Get PDF
    The Muon Upgrade Phase II of the Compact Muon Solenoid (CMS) aims to guarantee the optimal conditions of the present system and extend the eta coverage to ensure a reliable system for the High Luminosity Large Hadron Collider (HL-LHC) period. The Resistive Plate Chambers (RPCs) system will upgrade the off-detector electronics (called link system) of the chambers currently installed chambers and place improved RPCs (iRPCs) to cover the high pseudo-rapidity region, a challenging region for muon reconstruction in terms of background and momentum resolution. In order to find the best option for the iRPCs, an R&D program for new detectors was performed and real size prototypes have been tested in the Gamma Irradiation Facility (GIF++) at CERN. The results indicated that the technology suitable for the high background conditions is based on High Pressure Laminate (HPL) double-gap RPC. The RPC Upgrade Phase II program is planned to be ready after the Long Shutdown 3 (LS3)

    High voltage calibration method for the CMS RPC detector

    Get PDF
    The Resistive Plate Chambers (RPC) are used for muon triggers in the CMS experiment. To calibrate the high voltage working-points (WP) and identify degraded detectors due to radiation or chemical damage, a high voltage scan has been performed using 2017 data from pp collisions at a center-of-mass energy of 13 TeV. In this paper, we present the calibration method and the latest results obtained for the 2017 data. A comparison with all scans taken since 2011 is considered to investigate the stability of the detector performance in time

    CMSRPC efficiency measurement using the tag-and-probe method

    Get PDF
    We measure the efficiency of CMS Resistive Plate Chamber (RPC) detectors in proton-proton collisions at the centre-of-mass energy of 13 TeV using the tag-and-probe method. A muon from a Z(0) boson decay is selected as a probe of efficiency measurement, reconstructed using the CMS inner tracker and the rest of CMS muon systems. The overall efficiency of CMS RPC chambers during the 2016-2017 collision runs is measured to be more than 96% for the nominal RPC chambers

    The CMS RPC detector performance and stability during LHC RUN-2

    Get PDF
    The CMS experiment, located at the Large Hadron Collider (LHC) in CERN, has a redundant muon system composed by three different gaseous detector technologies: Cathode Strip Chambers (in the forward regions), Drift Tubes (in the central region), and Resistive Plate Chambers (both its central and forward regions). All three are used for muon reconstruction and triggering. The CMS RPC system confers robustness and redundancy to the muon trigger. The RPC system operation in the challenging background and pileup conditions of the LHC environment is presented. The RPC system provides information to all muon track finders and thus contributing to both muon trigger and reconstruction. The summary of the detector performance results obtained with proton-proton collision at root s = 13 TeV during 2016 and 2017 data taking have been presented. The stability of the system is presented in terms of efficiency and cluster size vs time and increasing instantaneous luminosity. Data-driven predictions about the expected performance during High Luminosity LHC (HL-LHC) stage have been reported

    RPC radiation background simulations for the high luminosity phase in the CMS experiment

    Get PDF
    The high luminosity expected from the HL-LHC will be a challenge for the CMS detector. The increased rate of particles coming from the collisions and the radioactivity induced in the detector material could cause significant damage and result in a progressive degradation of its performance. Simulation studies are very useful in these scenarios as they allow one to study the radiation environment and the impact on detector performance. Results are presented for CMS RPC stations considering the operating conditions expected at the HL-LHC

    R&D towards the CMS RPC Phase-2 upgrade

    Get PDF
    The high pseudo-rapidity region of the CMS muon system is covered by Cathode Strip Chambers (CSC) only and lacks redundant coverage despite the fact that it is a challenging region for muons in terms of backgrounds and momentum resolution. In order to maintain good efficiency for the muon trigger in this region additional RPCs are planned to be installed in the two outermost stations at low angle named RE3/1 and RE4/1. These stations will use RPCs with finer granularity and good timing resolution to mitigate background effects and to increase the redundancy of the system

    Quality Certification 4 (QC4) for RE4 in the Upgrade in CMS

    No full text
    The CMS muon system consist of Drif Tubes (DTs) in barrel region, Cathode Strip Chambers (CSCs) in the end-cap region and Resistive Plate Chambers (RPCs) in both regions. The RPCs with their excellent time resolution were chosen as dedicated muon trigger detector for the CMS experiment. After the Long Shutdown 1 (LS1) the LHC luminosity should reach 10(34)cm(-2)s(-1) thus it is necessary to improve the level 1 trigger efficiency of the CMS detector for this high luminosity, to achieve that a 4th RPCs layer (RE4) in both end-caps of the CMS detector and all the components must be installed and completely validated. Based on the valuable experience (Barrel & Endcap) are defined several steps of Quality Certification (QC): QC1 (Components), QC2 (Gaps), QC3 (Chambers), QC4 (chambers & Super Modules), QC5 (Commissioning at P5). In this work is presented some results of QC4

    R&D of a real-size mosaic MRPC within the framework of the CMS muon upgrade

    No full text
    Based on previous experience and attempt, a real-size mosaic Multi-gap Resistive Plate Chamber (MRPC) has been developed within the framework of the CMS muon upgrade efforts. The chamber is a 5-gap with plates made each of 6 pieces of low resistive glass. Cosmic ray test at CERN 904 shows that its efficiency can reach above 95% with a gas mixture of 90% C2H2F4, 5% i-C4H10 and 5% SF6. The chamber was also tested with CMS dry gas(95.2% C2H2F4, 4.5% i-C4H10, 0.3% SF6) at the CERN Gamma Irradiation Facility (GIF++). Efficiency results calculated by a simple tracking method show that the good performance is maintained at rates up to 10 kHz/cm(2)
    corecore