13 research outputs found

    Free-Breathing Diffusion Tensor Imaging and Tractography of the Human Heart in Healthy Volunteers Using Wavelet-Based Image Fusion

    No full text
    International audienceFree-breathing cardiac diffusion tensor imaging (DTI) is a promising but challenging technique for the study of fiber structures of the human heart in vivo. This work proposes a clinically compatible and robust technique to provide three-dimensional (3-D) fiber architecture properties of the human heart. To this end, 10 short-axis slices were acquired across the entire heart using a multiple shifted trigger delay (TD) strategy under free breathing conditions. Interscan motion was first corrected automatically using a nonrigid registration method. Then, two post-processing schemes were optimized and compared: an algorithm based on principal component analysis (PCA) filtering and temporal maximum intensity projection (TMIP), and an algorithm that uses the wavelet-based image fusion (WIF) method. The two methods were applied to the registered diffusion-weighted (DW) images to cope with intrascan motion-induced signal loss. The tensor fields were finally calculated, from which fractional anisotropy (FA), mean diffusivity (MD), and 3-D fiber tracts were derived and compared. The results show that the comparison of the FA values (FA(PCATMIP) = 0.45 ±0.10, FA(WIF) = 0.42 ±0.05, P=0.06) showed no significant difference, while the MD values ( MD(PCATMIP)=0.83 ±0.12×10(-3) mm (2)/s, MD(WIF)=0.74±0.05×10(-3) mm (2)/s, P=0.028) were significantly different. Improved helix angle variations through the myocardium wall reflecting the rotation characteristic of cardiac fibers were observed with WIF. This study demonstrates that the combination of multiple shifted TD acquisitions and dedicated post-processing makes it feasible to retrieve in vivo cardiac tractographies from free-breathing DTI acquisitions. The substantial improvements were observed using the WIF method instead of the previously published PCATMIP technique

    In vivo free-breathing DTI and IVIM of the whole human heart using a real-time slice-followed SE-EPI navigator-based sequence: A reproducibility study in healthy volunteers

    No full text
    International audienceIn this study, we proposed an efficient free-breathing strategy for rapid and improved cardiac diffusion-weighted imaging (DWI) acquisition using a single-shot spin-echo echo planar imaging (SE-EPI) sequence. Methods: A real-time slice-following technique during free-breathing was combined with a sliding acquisition-window strategy prior Principal Component Analysis temporal Maximum Intensity Projection (PCAtMIP) postprocessing of in-plane co-registered diffusion-weighted images. This methodology was applied to 10 volunteers to quantify the performance of the motion correction technique and the reproducibility of diffusion parameters. Results: The slice-following technique offers a powerful head–foot respiratory motion management solution for SE-EPI cDWI with the advantage of a 100% duty cycle scanning efficiency. The level of co-registration was further improved using nonrigid motion corrections and was evaluated with a co-registration index. Vascular fraction f and the diffusion coefficients D and D* were determined to be 0.122 ± 0.013, 1.41 ± 0.09 × 10−3 mm2/s and 43.6 ± 9.2 × 10−3 mm2/s, respectively. From the multidirectional dataset, the measured mean diffusivity was 1.72 ± 0.09 × 10−3 mm2/s and the fractional anisotropy was 0.36 ± 0.02. Conclusion: The slice-following DWI SE-EPI sequence is a promising solution for clinical implementation, offering a robust improved workflow for further evaluation of DWI in cardiology. Magn Reson Med, 2015. © 2015 Wiley Periodicals, Inc

    Neurovascular stent artifacts in 3D-TOF and 3D-PCMRI: Influence of stent design on flow measurement

    No full text
    Purpose: The morphological and hemodynamic evaluations of neurovascular diseases treated with stents would benefit from noninvasive imaging techniques such as 3D time-of-flight MRI (3D-TOF) and 3D phase contrast MRI (3D-PCMRI). For this purpose, a comprehensive evaluation of the stent artifacts and their impact on the flow measurement is critical.Methods: The artifacts of a representative sample of neurovascular stents were evaluated in vitro with 3D-TOF and 3D-PCMRI sequences. The dependency of the artifacts with respect to the orientation was analyzed for each stent design as well as the impact on the flow measurement accuracy. Furthermore, the 3D-PCMRI data of four patients carrying intracranial aneurysms treated with flow diverter stents were analyzed as illustrative examples.Results: The stent artifacts were mainly confined to the stent lumen therefore indicating the leading role of shielding effect. The influence of the stent design and its orientation with respect to the transmitting MR coils were highlighted. The artifacts impacted the 3D-PCMRI velocities mainly in the low magnitude domains, which were discarded from the analysis ensuring reliable near-stent velocities. The feasibility of in-stent flow measurements was confirmed in vivo on two patients who showed strong correlation between flow and geometric features. In two other patients, the consistency of out-of-stent velocities was verified qualitatively through intraaneurysmal streamlines except when susceptibility artifacts occurred.Conclusion: The present results motivate the conception of low inductance or non-conductive stent design. Furthermore, the feasibility of near-stent 3D-PCMRI measurements opens the door to clinical applications like the post-treatment follow-up of stenoses or intracranial aneurysms
    corecore