200 research outputs found

    Laparoscopic ventral hernia repair is safe and cost effective

    Get PDF
    Background: Ventral hernia repair is increasingly performed by laparoscopic means since the introduction of dual-layer meshes. This study aimed to compare the early complications and cost effectiveness of open hernia repair with those associated with laparoscopic repair. Methods: Open ventral hernia repair was performed for 92 consecutive patients using a Vypro mesh, followed by laparoscopic repair for 49 consecutive patients using a Parietene composite mesh. Results: The rate of surgical-site infections was significantly higher with open ventral hernia repair (13 vs 1; p = 0.03). The median length of hospital stay was significantly shorter with laparoscopic surgery (7 vs 6 days; p = 0.02). For laparoscopic repair, the direct operative costs were higher (2,314 vs 2,853 euros; p = 0.03), and the overall hospital costs were lower (9,787 vs 7,654 euros; p = 0.02). Conclusions: Laparoscopic ventral hernia repair leads to fewer surgical-site infections and a shorter hospital stay than open repair. Despite increased operative costs, overall hospital costs are lowered by laparoscopic ventral hernia repai

    The V-Y Latissimus Dorsi Musculocutaneous Flap in the Reconstruction of Large Posterior Chest Wall Defects

    Get PDF
    Posterior chest wall defects are frequently encountered after excision of tumors as a result of trauma or in the setting of wound dehiscence after spine surgery. Various pedicled fasciocutaneous and musculocutaneous flaps have been described for the coverage of these wounds. The advent of perforator flaps has allowed the preservation of muscle function but their bulk is limited. Musculocutaneous flaps remain widely employed. The trapezius and the latissimus dorsi (LD) flaps have been used extensively for upper and middle posterior chest wounds, respectively. Their bulk allows for obliteration of the dead space in deep wounds. The average width of the LD skin paddle is limited to 10-12cm if closure of the donor site is expected without skin grafting. In 2001 a modification of the skin paddle design was introduced in order to allow large flaps to be raised without requiring grafts or flaps for donor site closure. This V-Y pattern allows coverage of large anterior chest defects after mastectomy. We have modified this flap to allow its use for posterior chest wall defects. We describe the flap design, its indications, and its limitations with three clinical cases. Level of Evidence V This journal requires that authors assign a level of evidence to each article. For a full description of these Evidence-Based Medicine ratings, please refer to the Table of Contents or the online Instructions to Authors at www.springer.com/0026

    Nylon-6/chitosan core/shell antimicrobial nanofibers for the prevention of mesh-associated surgical site infection

    Get PDF
    The state-of-the-art hernia meshes, used in hospitals for hernia repair, are predominantly polymeric textile-based constructs that present high mechanical strength, but lack antimicrobial properties. Consequently, preventing bacterial colonization of implanted prosthetic meshes is of major clinical relevance for patients undergoing hernia repair. In this study, the co-axial electrospinning technique was investigated for the development of a novel mechanically stable structure incorporating dual drug release antimicrobial action. Core/shell structured nanofibers were developed, consisting of Nylon-6 in the core, to provide the appropriate mechanical stability, and Chitosan/Polyethylene oxide in the shell to provide bacteriostatic action. The core/shell structure consisted of a binary antimicrobial system incorporating 5-chloro-8-quinolinol in the chitosan shell, with the sustained release of Poly(hexanide) from the Nylon-6 core of the fibers. Homogeneous nanofibers with a "beads-in-fiber" architecture were observed by TEM, and validated by FTIR and XPS. The composite nanofibrous meshes significantly advance the stress-strain responses in comparison to the counterpart single-polymer electrospun meshes. The antimicrobial effectiveness was evaluated in vitro against two of the most commonly occurring pathogenic bacteria; S. aureus and P. aeruginosa, in surgical site infections. This study illustrates how the tailoring of core/shell nanofibers can be of interest for the development of active antimicrobial surfaces

    No signs of check-list fatigue - introducing the StOP? intra-operative briefing enhances the quality of an established pre-operative briefing in a pre-post intervention study.

    Get PDF
    The team timeout (TTO) is a safety checklist to be performed by the surgical team prior to incision. Exchange of critical information is, however, important not only before but also during an operation and members of surgical teams frequently feel insufficiently informed by the operating surgeon about the ongoing procedure. To improve the exchange of critical information during surgery, the StOP?-protocol was developed: At appropriate moments during the procedure, the leading surgeon briefly interrupts the operation and informs the team about the current Status (St) and next steps/objectives (O) of the operation, as well as possible Problems (P), and encourages questions of other team members (?). The StOP?-protocol draws attention to the team. Anticipating the occurrence of StOP?-protocols may support awareness of team processes and quality issues from the beginning and thus support other interventions such as the TTO; however, it also may signal an additional demand and contribute to a phenomenon akin to "checklist fatigue." We investigated if, and how, the introduction of the StOP?-protocol influenced TTO quality. This was a prospective intervention study employing a pre-post design. In the visceral surgical departments of two university hospitals and one urban hospital the quality of 356 timeouts (out of 371 included operation) was assessed by external observers before (154) and after (202) the introduction of the StOP?-briefing. Timeout quality was rated in terms of timeout completeness (number of checklist items mentioned) and timeout quality (engagement, pace, social atmosphere, noise). As compared to the baseline, after the implementation of the StOP?-protocol, observed timeouts had higher completeness ratings (F = 8.69, p = 0.003) and were rated by observers as higher in engagement (F = 13.48, p < 0.001), less rushed (F = 14.85, p < 0.001), in a better social atmosphere (F = 5.83, p < 0.016) and less noisy (F = 5.35, p < 0.022). Aspects of TTO are affected by the anticipation of StOP?-protocols. However, rather than harming the timeout goals by inducing "checklist fatigue," it increases completeness and quality of the team timeout

    Dissection and hemostasis with hydroxilated polyvinyl acetal tampons in open thyroid surgery

    Get PDF
    BACKGROUND: The essential objectives for thyroidectomy are: avoidance of injury to the recurrent laryngeal nerves, conservation of the parathyroid glands, an accurate haemostasis and an excellent cosmesis. In the last 10 years major improvements and new technologies have been proposed and applied in thyroid surgery; among these mini-invasive thyroidectomy, regional anaesthesia and intraoperative neuromonitoring, and new devices for achieving dissection and haemostasis. Minor bleeding from small vessels could be a major complication in thyroid surgery. The purpose of ligating vessels is to maintain the surgical site free from an excess of blood and reduce blood loss in the patient. MATERIALS AND METHODS: Hydroxylated polyvinyl acetal tampons (HPA) are made by a synthetic, open cell foam structure able to absorb fluids up to 25 times the initial weight. We tested their efficacy for small bleeding control and tissue dissection during several thyroid procedures. RESULTS: HPA tampons have been found extremely useful to absorb blood coming from minor and diffuse loss, helping to control bleeding by a combined action of fluid absorption and local compression. The porous design of the tampon allows the use of the suction device right through the tampon itself. Thanks to the initial mildly hard consistency, we also used HPA tampons as dissecting instruments. CONCLUSION: In our experience the use of HPA tampons resulted extremely efficient for minor bleeding control, fluids removal and tissue dissection during thyroid surgery

    Elevated levels of placental growth factor represent an adaptive host response in sepsis

    Get PDF
    Recently, we demonstrated that circulating levels of vascular endothelial growth factor (VEGF) and placental growth factor (PlGF) are increased in sepsis (Yano, K., P.C. Liaw, J.M. Mullington, S.C. Shih, H. Okada, N. Bodyak, P.M. Kang, L. Toltl, B. Belikoff, J. Buras, et al. 2006. J. Exp. Med. 203:1447–1458). Moreover, enhanced VEGF/Flk-1 signaling was shown to contribute to sepsis morbidity and mortality. We tested the hypothesis that PlGF also contributes to sepsis outcome. In mouse models of endotoxemia and cecal ligation puncture, the genetic absence of PlGF or the systemic administration of neutralizing anti-PlGF antibodies resulted in higher mortality compared with wild-type or immunoglobulin G–injected controls, respectively. The increased mortality associated with genetic deficiency of PlGF was reversed by adenovirus (Ad)-mediated overexpression of PlGF. In the endotoxemia model, PlGF deficiency was associated with elevated circulating levels of VEGF, induction of VEGF expression in the liver, impaired cardiac function, and organ-specific accentuation of barrier dysfunction and inflammation. Mortality of endotoxemic PlGF-deficient mice was increased by Ad-mediated overexpression of VEGF and was blocked by expression of soluble Flt-1. Collectively, these data suggest that up-regulation of PlGF in sepsis is an adaptive host response that exerts its benefit, at least in part, by attenuating VEGF signaling

    Effect of fluid resuscitation on mortality and organ function in experimental sepsis models

    Get PDF
    Introduction Several recent studies have shown that a positive fluid balance in critical illness is associated with worse outcome. We tested the effects of moderate vs. high-volume resuscitation strategies on mortality, systemic and regional blood flows, mitochondrial respiration, and organ function in two experimental sepsis models. Methods 48 pigs were randomized to continuous endotoxin infusion, fecal peritonitis, and a control group (n = 16 each), and each group further to two different basal rates of volume supply for 24 hours [moderate-volume (10 ml/kg/h, Ringer's lactate, n = 8); high-volume (15 + 5 ml/kg/h, Ringer's lactate and hydroxyethyl starch (HES), n = 8)], both supplemented by additional volume boli, as guided by urinary output, filling pressures, and responses in stroke volume. Systemic and regional hemodynamics were measured and tissue specimens taken for mitochondrial function assessment and histological analysis. Results Mortality in high-volume groups was 87% (peritonitis), 75% (endotoxemia), and 13% (controls). In moderate-volume groups mortality was 50% (peritonitis), 13% (endotoxemia) and 0% (controls). Both septic groups became hyperdynamic. While neither sepsis nor volume resuscitation strategy was associated with altered hepatic or muscle mitochondrial complex I- and II-dependent respiration, non-survivors had lower hepatic complex II-dependent respiratory control ratios (2.6 +/- 0.7, vs. 3.3 +/- 0.9 in survivors; P = 0.01). Histology revealed moderate damage in all organs, colloid plaques in lung tissue of high-volume groups, and severe kidney damage in endotoxin high-volume animals. Conclusions High-volume resuscitation including HES in experimental peritonitis and endotoxemia increased mortality despite better initial hemodynamic stability. This suggests that the strategy of early fluid management influences outcome in sepsis. The high mortality was not associated with reduced mitochondrial complex I- or II-dependent muscle and hepatic respiration

    Anisotropic excitation of surface plasmon polaritons on a metal film by a scattering-type scanning near-field microscope with a nonrotationally-symmetric probe tip

    Get PDF
    We investigated the excitation of surface plasmon polaritons on gold films with the metallized probe tip of a scattering-type scanning near-field optical microscope (s-SNOM). The emission of the polaritons from the tip, illuminated by near-infrared laser radiation, was found to be anisotropic and not circularly symmetric as expected on the basis of literature data. We furthermore identified an additional excitation channel via light that was reflected off the tip and excited the plasmon polaritons at the edge of the metal film. Our results, while obtained for a non-rotationally-symmetric type of probe tip and thus specific for this situation, indicate that when an s-SNOM is employed for the investigation of plasmonic structures, the unintentional excitation of surface waves and anisotropic surface wave propagation must be considered in order to correctly interpret the signatures of plasmon polariton generation and propagation

    Tumor Necrosis Factor-Related Apoptosis-Inducing Ligand on NK Cells Protects From Hepatic Ischemia-Reperfusion Injury

    Get PDF
    BACKGROUND: Ischemia-reperfusion injury (IRI) significantly contributes to graft dysfunction after liver transplantation. Natural killer (NK) cells are crucial innate effector cells in the liver and express tumor necrosis factor-related apoptosis-inducing ligand (TRAIL), a potent inducer of hepatocyte cell death. Here, we investigated if TRAIL expression on NK cells contributes to hepatic IRI. METHODS: The outcome after partial hepatic IRI was assessed in TRAIL-null mice and contrasted to C57BL/6J wild-type mice and after NK cell adoptive transfer in RAG2/common gamma-null mice that lack T, B, and NK cells. Liver IRI was assessed by histological analysis, alanine aminotransferase, hepatic neutrophil activation by myeloperoxidase activity, and cytokine secretion at specific time points. NK cell cytotoxicity and differentiation were assessed in vivo and in vitro. RESULTS: Twenty-four hours after reperfusion, TRAIL-null mice exhibited significantly higher serum transaminases, histological signs of necrosis, neutrophil infiltration, and serum levels of interleukin-6 compared to wild-type animals. Adoptive transfer of TRAIL-null NK cells into immunodeficient RAG2/common gamma-null mice was associated with significantly elevated liver damage compared to transfer of wild-type NK cells. In TRAIL-null mice, NK cells exhibit higher cytotoxicity and decreased differentiation compared to wild-type mice. In vitro, cytotoxicity against YAC-1 and secretion of interferon gamma by TRAIL-null NK cells were significantly increased compared to wild-type controls. CONCLUSIONS: These experiments reveal that expression of TRAIL on NK cells is protective in a murine model of hepatic IRI through modulation of NK cell cytotoxicity and NK cell differentiation

    Endothelial- and Platelet-Derived Microparticles Are Generated During Liver Resection in Humans

    Get PDF
    BACKGROUND Cell-derived plasma microparticles (<1.5 μm) originating from various cell types have the potential to regulate thrombogenesis and inflammatory responses. The aim of this study was to test the hypothesis that microparticles generated during hepatic surgery co-regulate postoperative procoagulant and proinflammatory events. METHODS In 30 patients undergoing liver resection, plasma microparticles were isolated, quantitated, and characterized as endothelial (CD31+, CD41-), platelet (CD41+), or leukocyte (CD11b+) origin by flow cytometry and their procoagulant and proinflammatory activity was measured by immunoassays. RESULTS During liver resection, the total numbers of microparticles increased with significantly more Annexin V-positive, endothelial and platelet-derived microparticles following extended hepatectomy compared to standard and minor liver resections. After liver resection, microparticle tissue factor and procoagulant activity increased along with overall coagulation as assessed by thrombelastography. Levels of leukocyte-derived microparticles specifically increased in patients with systemic inflammation as assessed by C-reactive protein but are independent of the extent of liver resection. CONCLUSIONS Endothelial and platelet-derived microparticles are specifically elevated during liver resection, accompanied by increased procoagulant activity. Leukocyte-derived microparticles are a potential marker for systemic inflammation. Plasma microparticles may represent a specific response to surgical stress and may be an important mediator of postoperative coagulation and inflammation
    corecore