1,578 research outputs found

    Federal-Provincial Tax Equalization: An Evaluation

    Get PDF

    A rapid method for the in-field analysis of amphetamines employing the agilent bioanalyzer

    Full text link
    This paper reports the first analysis of small molecules on the Agilent bio-analyser. The Bioanalyzer is a commercial lab-on-a-chip instrument designed for the analysis of DNA and proteins. We demonstrate that the instrument is suitable for analyses beyond its design specifications. Amphetamine, methamphetamine and pseudoephedrine were separated with a 50 mM borate and 50 mM sodium dodecyl sulfate (SDS) buffer at pH 9.66. The analytes were derivatised with fluorescein isothiocyanate (FITC) in 3 minutes with a heating block set at 90°C, reducing the typical time of 12 hours required for amine-labelling. Analytes were detected by LED-induced fluorescence (λ = 525 nm and λ = 470 nm). Furthermore, five amphetamine analogues were baseline separated within 1 minute. An average limit of detection of 0.6 mg mL -1 and limit of quantification of 2.2μ mg mL-1 were obtained for all analytes. These rapid analyses in conjunction with a fast and reliable derivatisation method with FITC demonstrate its potential use for the in-field analysis of samples of forensic significance. © 2011 The Royal Society of Chemistry

    Screening of gunshot residues using desorption electrospray ionisation-mass spectrometry (DESI-MS)

    Full text link
    Several studies have indicated that there are potential environmental sources of particles resembling inorganic primer found in gunshot residues (GSR); as a consequence examiners are reluctant to unambiguously assign the origin of inorganic particles. If organic gunshot residues (OGSR) were found in combination with inorganic particles, the possibility of environmental sources could be potentially eliminated, thereby significantly enhancing the strength of the evidence.Methods have been previously described whereby GSR specimens can be analysed for the presence of OGSR or inorganic GRS (IGSR). However, no methods have been reported that allow the analysis of both OGSR and IGSR on the same specimen.Described in this article is a direct method using desorption electrospray ionisation-mass spectrometry (DESI-MS) for the detection of methyl centralite (MC), ethyl centralite (EC) and diphenylamine (DPA) on adhesive tape GSR stubs typically used for scanning electron microscopy-energy-dispersive X-ray (SEM-EDX) analysis. The optimisation of numerous parameters was conducted using an experimental design. The results indicate that direct analysis of these organic components of GSR is possible although some limitations were also identified.This initial investigation has also indicated that subjecting stubs to DESI analysis does not interfere with subsequent SEM-EDX analysis of primer residues; therefore the technique described herein allows a comprehensive examination of GSR that would be highly probative in the event that both OGSR and IGSR are detected in the same specimen. © 2011 Elsevier Ireland Ltd

    Genetic variation and quantitative trait loci associated with developmental stability and the environmental correlation between traits in maize

    Get PDF
    11 páginas, 4 figuras, 5 tablas.There is limited experimental information about the genetic basis of micro-environmental variance (VE) (developmental stability) and environmental correlations. This study, by using a population of maize recombinant inbred lines (RIL) and simple sequence repeat (SSR) polymorphic markers, aims at the following: firstly, to quantify the genetic component of the VE or developmental stability for four traits in maize and the environmental correlation between these traits, and secondly, to identify quantitative trait loci (QTLs) that influence these quantities. We found that, when estimating variances and correlations and testing their homogeneity, estimates and tests are needed that are not highly dependent on normality assumptions. There was significant variation among the RILs in VE and in the environmental correlation for some of the traits, implying genetic heterogeneity in the VE and environmental correlations. The genetic coefficient of variation of the environmental variance (GCVVE) was estimated to be 20%, which is lower than estimates obtained for other species. A few genomic regions involved in the stability of one trait or two traits were detected, and these did not have an important influence on the mean of the trait. One region that could be associated with the environmental correlations between traits was also detected.The National Plan for Research and Development of Spain (project code AGL2006-13140) is acknowledged for financial support. B. Ordas acknowledges a contract from the Spanish National Research Council (I3P Program).Peer reviewe

    Detection of gunshot residues using mass spectrometry

    Full text link
    In recent years, forensic scientists have become increasingly interested in the detection and interpretation of organic gunshot residues (OGSR) due to the increasing use of lead- and heavy metal-free ammunition. This has also been prompted by the identification of gunshot residue- (GSR-) like particles in environmental and occupational samples. Various techniques have been investigated for their ability to detect OGSR. Mass spectrometry (MS) coupled to a chromatographic system is a powerful tool due to its high selectivity and sensitivity. Further, modern MS instruments can detect and identify a number of explosives and additives which may require different ionization techniques. Finally, MS has been applied to the analysis of both OGSR and inorganic gunshot residue (IGSR), although the "gold standard" for analysis is scanning electron microscopy with energy dispersive X-ray microscopy (SEM-EDX). This review presents an overview of the technical attributes of currently available MS and ionization techniques and their reported applications to GSR analysis. © 2014 Regina Verena Taudte et al

    A portable explosive detector based on fluorescence quenching of pyrene deposited on coloured wax-printed μpADs

    Full text link
    A new technique for the detection of explosives has been developed based on fluorescence quenching of pyrene on paper-based analytical devices (μPADs). Wax barriers were generated (150 °C, 5 min) using ten different colours. Magenta was found as the most suitable wax colour for the generation of the hydrophobic barriers with a nominal width of 120 μm resulting in fully functioning hydrophobic barriers. One microliter of 0.5 mg mL-1 pyrene dissolved in an 80 : 20 methanol-water solution was deposited on the hydrophobic circle (5 mm diameter) to produce the active microchip device. Under ultra-violet (UV) illumination, ten different organic explosives were detected using the μPAD, with limits of detection ranging from 100-600 ppm. A prototype of a portable battery operated instrument using a 3 W power UV light-emitting-diode (LED) (365 nm) and a photodiode sensor was also built and evaluated for the successful automatic detection of explosives and potential application for field-based screening. © 2013 The Royal Society of Chemistry

    Collective Flow from the Intranuclear Cascade Model

    Get PDF
    The phenomenon of collective flow in relativistic heavy ion collisions is studied using the hadronic cascade model ARC. Direct comparison is made to data gathered at the Bevalac, for Au+Au at p=12p=1-2 GeV/c. In contrast to the standard lore about the cascade model, collective flow is well described quantitatively without the need for explicit mean field terms to simulate the nuclear equation of state. Pion collective flow is in the opposite direction to nucleon flow as is that of anti-nucleons and other produced particles. Pion and nucleon flow are predicted at AGS energies also, where, in light of the higher baryon densities achieved, we speculate that equation of state effects may be observable.Comment: 9 pages, 2 figures include

    Percolation diffusion into self-assembled mesoporous silica microfibres

    Full text link
    © 2014 by the authors. Percolation diffusion into long (11.5 cm) self-assembled, ordered mesoporous microfibres is studied using optical transmission and laser ablation inductive coupled mass spectrometry (LA-ICP-MS). Optical transmission based diffusion studies reveal rapid penetration ( 80 μm2·s−1) of Rhodamine B with very little percolation of larger molecules such as zinc tetraphenylporphyrin (ZnTPP) observed under similar loading conditions. The failure of ZnTPP to enter the microfibre was confirmed, in higher resolution, using LA-ICP-MS. In the latter case, LA-ICP-MS was used to determine the diffusion of zinc acetate dihydrate, D~3 × 10−4 nm2·s−1. The large differences between the molecules are accounted for by proposing ordered solvent and structure assisted accelerated diffusion of the Rhodamine B based on its hydrophilicity relative to the zinc compounds. The broader implications and applications for filtration, molecular sieves and a range of devices and uses are described

    A patient tumour-on-a-chip system for personalised investigation of radiotherapy based treatment regimens

    Get PDF
    Development of personalised cancer models to predict response to radiation would benefit patient care; particularly in malignancies where treatment resistance is prevalent. Herein, a robust, easy to use, tumour-on-a-chip platform which maintains precision cut head and neck cancer for the purpose of ex vivo irradiation is described. The device utilises sintered discs to separate the biopsy and medium, mimicking in vivo microvascular flow and diffusion, maintaining tissue viability for 68 h. Integrity of tissues is demonstrated by the low levels of lactate dehydrogenase release and retained histology, accompanied by assessment of cell viability by trypan blue exclusion and flow cytometry; fluid dynamic modelling validates culture conditions. An irradiation jig is described for reproducible delivery of clinically-relevant doses (5 × 2 Gy) to newly-presenting primary tumours (n = 12); the addition of concurrent cisplatin is also investigated (n = 8) with response analysed by immunohistochemistry. Fractionated irradiation reduced proliferation (BrdU, p = 0.0064), increased DNA damage (ƴH2AX, p = 0.0043) and caspase-dependent apoptosis (caspase-cleaved cytokeratin-18) compared to control; caspase-dependent apoptosis was further increased by concurrent cisplatin compared to control (p = 0.0063). This is a proof of principle study showing the response of cancer tissue to irradiation ex vivo in a bespoke system. The novel platform described has the potential to personalise treatment for patients in a cost-effective manner with applicability to any solid tumour

    Secondary transfer of organic gunshot residues: Empirical data to assist the evaluation of three scenarios.

    Get PDF
    The present study aimed at providing data to assess the secondary transfer of organic gunshot residues (OGSR). Three scenarios were evaluated in controlled conditions, namely displacing a firearm from point A to point B, a simple handshake and an arrest involving handcuffing on the ground. Specimens were collected from the firearm, the hands of the shooter and the non-shooter undergoing the secondary transfer in order to compare the amounts detected. Secondary transfer was observed for the three scenarios, but to a different extent. It was found that displacing a firearm resulted in secondary transfer in <50% of the experiments. The firearm also had an influence, as contrary to the pistol, no secondary OGSR were detected using the revolver. Shaking the hand of the shooter also transferred OGSR to the non-shooter's hand. In that case, the amount of OGSR was generally higher on the shooter than on the non-shooter. Finally, the largest secondary transfer was observed after the arrest with handcuffing with positive results in all cases using the pistol. In that scenario, the amounts on the shooter and the non-shooter were in the same range. This study highlights that the secondary transfer must be taken into account in the interpretation of OGSR. Indeed, an individual's hands might be contaminated by handling a firearm or having physical contact with a shooter
    corecore