81 research outputs found
Thermally induced magnetic switching in bit-patterned media
This article may be downloaded for personal use only. Any other use requires prior permission of the author and AIP Publishing. This article appeared in Journal of Applied Physics 122, 043907 (2017) and may be found at https://doi.org/10.1063/1.4992808.We have studied the thermal variation of the switching field of magnetic islands at room temperature. A model bit-pattern media composed of an assembly of islands with 80 nm width was fabricated by sputter deposition onto a pre-patterned substrate. Using direct magnetic-contrast imaging of the islands under applied field, we extract the switching probabilities of individual islands. Based on an analytical model for the thermally activated switching of the islands, we are able to determine the intrinsic magnetic anisotropy of each island and, consequentially, a distribution of anisotropies for the island ensemble investigated. In the distribution, we identify a separated group of islands with a particularly small anisotropy. We attribute this group to islands containing misaligned grains triggering the magnetic reversal. At room temperature and slow field sweep rates, the observed thermal broadening of the switching-field distribution is small compared to the intrinsic broadening. However, we illustrate that thermal fluctuations play a crucial role at high sweep rates by extrapolating our results to technological relevant regimes
Achieving diffraction-limited resolution in soft-X-ray Fourier-transform holography
The spatial resolution of microscopic images acquired via X-ray Fourier-transform holography is limited by the source size of the reference wave and by the numerical aperture of the detector. We analyze the interplay between both influences and show how they are matched in practice. We further identify, how high spatial frequencies translate to imaging artifacts in holographic reconstructions where mainly the reference beam limits the spatial resolution. As a solution, three methods are introduced based on numerical post-processing of the reconstruction. The methods comprise apodization of the hologram, refocusing via wave propagation, and deconvolution using the transfer function of the imaging system. In particular for the latter two, we demonstrate that image details smaller than the source size of the reference beam can be recovered up to the diffraction limit of the hologram. Our findings motivate the intentional application of a large reference-wave source enhancing the image contrast in applications with low photon numbers such as single-shot experiments at free-electron lasers or imaging at laboratory sources.BMBF, 05K10KTB, Verbundprojekt: FSP 301 - FLASH: Nanoskopische Systeme. Teilprojekt 1.1: Universelle Experimentierkammer für Streuexperimente mit kohärenten Femtosekunden-Röntgenpulsen Multi Purpose Coherent Scattering Chamber for FLASH and XFEL 'MPscatt
Experimental evaluation of signal-to-noise in spectro-holography via modified uniformly redundant arrays in the soft x-ray and extreme ultraviolet spectral regime
We present dichroic x-ray lensless magnetic imaging by Fourier transform holography with an extended reference scheme via a modified uniformly redundant array (mURA). Holographic images of magnetic domains simultaneously generated by a single pinhole reference as well as by a mURA reference are compared with respect to the signal-to-noise ratio (SNR) as a function of exposure time. We apply this approach for spectro-holographic imaging of ferromagnetic domain patterns in Co/Pt multilayer films. Soft x-rays with wavelengths of 1.59 nm (Co L 3 absorption edge) and 20.8 nm (Co M 2,3 absorption edges) are used for image formation and to generate contrast via x-ray magnetic circular dichroism. For a given exposure time, the mURA-based holography allows to decouple the reconstruction SNR from the spatial resolution. For 1.59 nm wavelength, the reconstruction via the extended reference scheme shows no significant loss of spatial resolution compared to the single pinhole reference. In contrast, at 20.8 nm wavelength the single pinhole reveals some very intricate features which are lost in the image generated by the mURA, although overall a high-quality image is generated. The SNR-advantage of the mURA scheme is most notable when the hologram has to be encoded with few photons, while errors associated with the increased complexity of the reconstruction process reduce the advantage for high-photon-number experiments.BMBF, 05K13KT3, Verbundprojekt 05K2013 - DynaMaX: Messplatz für ultraschnelle Dynamik bei BESSY II. Teilprojekt
Picosecond x-ray magnetic circular dichroism spectroscopy at the Fe L-edges with a laser-driven plasma source
Time-resolved x-ray magnetic circular dichroism (XMCD) enables a unique
spectroscopic view on complex spin and charge dynamics in multi-elemental
magnetic materials. So far, its application in the soft-x-ray range has been
limited to synchrotron-radiation sources and free-electron lasers. By combining
a laser-driven plasma source with a magnetic thin-film polarizer, we generate
circularly polarized photons in the soft x-ray regime, enabling the first XMCD
spectroscopy at the Fe L edges in a laser laboratory. Our approach can be
readily adapted to other transition metal L and rare earth M absorption edges
and with a temporal resolution of < 10 ps, a wide range of ultrafast
magnetization studies can be realized.Comment: 7 pages, 4 figures, supplemental materia
Singleshot polychromatic coherent diffractive imaging with a high-order harmonic source
© 2020 Optical Society of America. Users may use, reuse, and build upon the article, or use the article for text or data mining, so long as such uses are for non-commercial purposes and appropriate attribution is maintained. All other rights are reserved.Singleshot polychromatic coherent diffractive imaging is performed with a high-intensity high-order harmonic generation source. The coherence properties are analyzed and several reconstructions show the shot-to-shot fluctuations of the incident beam wavefront. The method is based on a multi-step approach. First, the spectrum is extracted from double-slit diffraction data. The spectrum is used as input to extract the monochromatic sample diffraction pattern, then phase retrieval is performed on the quasi-monochromatic data to obtain the sample’s exit surface wave. Reconstructions based on guided error reduction (ER) and alternating direction method of multipliers (ADMM) are compared. ADMM allows additional penalty terms to be included in the cost functional to promote sparsity within the reconstruction
Photon correlation spectroscopy with heterodyne mixing based on soft-x-ray magnetic circular dichroism
Many magnetic equilibrium states and phase transitions are characterized by
fluctuations. Such magnetic fluctuation can in principle be detected with
scattering-based x-ray photon correlation spectroscopy (XPCS). However, in the
established approach of XPCS, the magnetic scattering signal is quadratic in
the magnetic scattering cross section, which results not only in often
prohibitively small signals but also in a fundamental inability to detect
negative correlations (anticorrelations). Here, we propose to exploit the
possibility of heterodyne mixing of the magnetic signal with static charge
scattering to reconstruct the first-order (linear) magnetic correlation
function. We show that the first-order magnetic scattering signal reconstructed
from heterodyne scattering now directly represents the underlying magnetization
texture. Moreover, we suggest a practical implementation based on an absorption
mask rigidly connected to the sample, which not only produces a static charge
scattering signal but also eliminates the problem of drift-induced artificial
decay of the correlation functions. Our method thereby significantly broadens
the range of scientific questions accessible by magnetic x-ray photon
correlation spectroscopy
Recommended from our members
Reference shape effects on Fourier transform holography
Soft-x-ray holography which utilizes an optics mask fabricated in direct contact with the sample, is a widely applied x-ray microscopy method, in particular, for investigating magnetic samples. The optics mask splits the x-ray beam into a reference wave and a wave to illuminate the sample. The reconstruction quality in such a Fourier-transform holography experiment depends primarily on the characteristics of the reference wave, typically emerging from a small, high-aspect-ratio pinhole in the mask. In this paper, we study two commonly used reference geometries and investigate how their 3D structure affects the reconstruction within an x-ray Fourier holography experiment. Insight into these effects is obtained by imaging the exit waves from reference pinholes via high-resolution coherent diffraction imaging combined with three-dimensional multislice simulations of the x-ray propagation through the reference pinhole. The results were used to simulate Fourier-transform holography experiments to determine the spatial resolution and precise location of the reconstruction plane for different reference geometries. Based on our findings, we discuss the properties of the reference pinholes with view on application in soft-x-ray holography experiments
Multi-Color Imaging of Magnetic Co/Pt Multilayers
We demonstrate for the first time the realization of a spatial resolved two color, element-specific imaging experiment at the free-electron laser facility FERMI. Coherent imaging using Fourier transform holography was used to achieve direct real space access to the nanometer length scale of magnetic domains of Co/Pt heterostructures via the element-specific magnetic dichroism in the extreme ultraviolet spectral range. As a first step to implement this technique for studies of ultrafast phenomena we present the spatially resolved response of magnetic domains upon femtosecond laser excitation
Recommended from our members
Experimental evaluation of signal-to-noise in spectro-holography via modified uniformly redundant arrays in the soft x-ray and extreme ultraviolet spectral regime
We present dichroic x-ray lensless magnetic imaging by Fourier transform holography with an extended reference scheme via a modified uniformly redundant array (mURA). Holographic images of magnetic domains simultaneously generated by a single pinhole reference as well as by a mURA reference are compared with respect to the signal-to-noise ratio (SNR) as a function of exposure time. We apply this approach for spectro-holographic imaging of ferromagnetic domain patterns in Co/Pt multilayer films. Soft x-rays with wavelengths of 1.59 nm (Co L3 absorption edge) and 20.8 nm (Co M2,3 absorption edges) are used for image formation and to generate contrast via x-ray magnetic circular dichroism. For a given exposure time, the mURA-based holography allows to decouple the reconstruction SNR from the spatial resolution. For 1.59 nm wavelength, the reconstruction via the extended reference scheme shows no significant loss of spatial resolution compared to the single pinhole reference. In contrast, at 20.8 nm wavelength the single pinhole reveals some very intricate features which are lost in the image generated by the mURA, although overall a high-quality image is generated. The SNR-advantage of the mURA scheme is most notable when the hologram has to be encoded with few photons, while errors associated with the increased complexity of the reconstruction process reduce the advantage for high-photon-number experiments
- …