13,140 research outputs found
Microwave dosimeter - A concept
Dosimeter determines time-integrated radiation dosage to which an individual is exposed. Integration is measured chemically in proportion to radiation detected. Wearer receives an exposure measurement representing an average of the dose over the entire body
Metabolic simulation chamber
Metabolic simulation combustion chamber was developed as subsystem for breathing metabolic simulator. Entire system is used for evaluation of life support and resuscitation equipment. Metabolism subsystem simulates a human by consuming oxygen and producing carbon dioxide. Basic function is to simulate human metabolic range from rest to hard work
Temperature and humidity control of simulated human breath
Subsystem was developed for breathing metabolic simulator which adjusts temperature and humidity of air to levels of human exhaled breath. Temperature-humidity subsystem is described, consisting of aluminum enclosure with 400 watt heat sheet glued to bottom, vertical separators, inlet connection, and check valve
Simulated breath waveform control
Subsystem was developed which provides twelve waveform controls to breath drive mechanism. Twelve position, magnetically actuated rotary switch is connected to one end of crankshaft drive, such that it makes one complete revolution for each simulated breath. Connections with common wired point are included in modifications made to standard motor speed controller
A New Local Temperature Distribution Function for X-ray Clusters: Cosmological Applications
(abridged) We present a new determination of the local temperature function
of X-ray clusters. We use a new sample comprising fifty clusters for which
temperature information is now available, making it the largest complete sample
of its kind. It is therefore expected to significantly improve the estimation
of the temperature distribution function of moderately hot clusters. We find
that the resulting temperature function is higher than previous estimations,
but agrees well with the temperature distribution function inferred from the
BCS and RASS luminosity function. We have used this sample to constrain the
amplitude of the matter fluctuations on cluster's scale of
Mpc, assuming a mass-temperature relation based
on recent numerical simulations. We find for an
model. Our sample provides an ideal reference at to
use in the application of the cosmological test based on the evolution of X-ray
cluster abundance (Oukbir & Blanchard 1992, 1997). Using Henry's sample, we
find that the abundance of clusters at is significantly smaller, by
a factor larger than 2, which shows that the EMSS sample provides strong
evidence for evolution of the cluster abundance. A likelihood analysis leads to
a rather high value of the mean density parameter of the universe: (open case) and (flat case), which is
consistent with a previous, independent estimation based on the full EMSS
sample by Sadat et al.(1998). Some systematic uncertainties which could alter
this result are briefly discussed.Comment: 31 pages, 12 figures, mathches the version published in Astronomy and
Astrophysic
Geometrical multilayers: coercivity in magnetic 3-D nanostructures
Electrodeposition of magnetic metals through self-assembly templates from polystyrene spheres is used for fabrication of magnetic nanostructures with 3-D architectures. These arrays demonstrate unusual properties including an oscillatory dependence of the coercive field on film thickness. Numerical simulations reveal that the ratio between the array period and the hole diameter in anti-dot array is a crucial parameter giving rise to qualitatively distinct magnetization reversal regimes
Breathing-metabolic simulator
Breathing-metabolic simulator was developed to be used for evaluation of life support equipment. Apparatus simulates human breathing rate and controls temperature and humidity of exhaled air as well as its chemical composition. All functions are designed to correspond to various degrees of human response
An experimental investigation of propfan installations on an upswept supercritical wing at transonic Mach numbers
An investigation has been conducted in the Langley 16 Foot Transonic Tunnel to determine propfan installation and slipstream interference effects on an unswept supercritical wing. This data can be used for verification of existing and developing theoretical codes as well as giving an understanding of the flow interactions associated with propeller/nacelle/wing integration. The investigation was conducted over a Mach number range of 0.5 to 0.8 and at angles of attack from 0 deg to 3 deg. The propeller was powered by an air turbine simulator and the exhaust from the air turbine was used to simulate the exhaust from the propfan nacelle. Reynolds number based on wing chord varied from 3 to 4 million. Results indicate that the propfan causes an increase in the wing lift coefficient. It was found that most of the propeller induced swirl is recovered by the wing. The propeller slipstream also causes a large favorable leading edge suction peak on the upwash side and a smaller unfavorable decrease on the downwash side
ANOPP programmer's reference manual for the executive System
Documentation for the Aircraft Noise Prediction Program as of release level 01/00/00 is presented in a manual designed for programmers having a need for understanding the internal design and logical concepts of the executive system software. Emphasis is placed on providing sufficient information to modify the system for enhancements or error correction. The ANOPP executive system includes software related to operating system interface, executive control, and data base management for the Aircraft Noise Prediction Program. It is written in Fortran IV for use on CDC Cyber series of computers
- …