186 research outputs found

    Follow-Up Assessment of Intracranial Aneurysms Treated with Endovascular Coiling: Comparison of Compressed Sensing and Parallel Imaging Time-of-Flight Magnetic Resonance Angiography

    Get PDF
    The aim of our study was to compare compressed sensing (CS) time-of-flight (TOF) magnetic resonance angiography (MRA) with parallel imaging (PI) TOF MRA in the evaluation of patients with intracranial aneurysms treated with coil embolization or stent-assisted coiling. We enrolled 22 patients who underwent follow-up imaging after intracranial aneurysm coil embolization. All patients underwent both PI TOF and CS TOF MRA during the same examination. Image evaluation aimed to compare the performance of CS to PI TOF MRA in determining the degree of aneurysm occlusion, as well as the depiction of parent vessel and vessels adjacent to the aneurysm dome. The reference standard for the evaluation of aneurysm occlusion was PI TOF MRA. The inter-modality agreement between CS and PI TOF MRA in the evaluation of aneurysm occlusion was almost perfect (κ = 0.98, p < 0.001) and the overall inter-rater agreement was substantial (κ = 0.70, p < 0.001). The visualization of aneurysm parent vessel in CS TOF images compared with PI TOF images was evaluated to be better in 11.4%, equal in 86.4%, and worse in 2.3%. CS TOF MRA, with almost 70% scan time reduction with respect to PI TOF MRA, yields comparable results for assessing the occlusion status of coiled intracranial aneurysms. Short scan times increase patient comfort, reduce the risk of motion artifacts, and increase patient throughput, with a resulting reduction in costs. CS TOF MRA may therefore be a potential replacement for PI TOF MRA as a first-line follow-up examination in patients with intracranial aneurysms treated with coil embolization

    Status of the RFX experiment

    Get PDF
    The first results obtained in the RFX reversed field pinch experiment after the 1995 machine modifications are reported. The confinement, for fully stationary discharges at 0.6 MA, has now reached the expected values, even in the presence of MHD wall locked modes. Studies on locked mode effects have evidenced currents flowing from the plasma into the vessel in the region of locking. Measurements on plasma rotation and radial electric field have shown a perpendicular velocity shear at the edge similar to what is found in tokamaks and stellarators. New measurements on edge superthermal electrons and some evidence of their correlation with plasma core characteristics are included

    Cognitive profile in idiopathic autonomic failure: relation with white matter hyperintensities and neurofilament levels

    Get PDF
    To disclose the nature of cognitive deficits in a cohort of patients with idiopathic autonomic failure (IAF) by exploring the relation among cognitive functions, cardiovascular autonomic failure (AF) and clinical progression to another α-synucleinopathy (phenoconversion)
    corecore