1,005 research outputs found

    Characterisation of prostate lesions using transrectal shear wave elastography (SWE) ultrasound imaging:a systematic review

    Get PDF
    Background ultrasound-based shear wave elastography (SWE) can non-invasively assess prostate tissue stiffness. This systematic review aims to evaluate SWE for the detection of prostate cancer (PCa) and compare diagnostic estimates between studies reporting the detection of all PCa and clinically significant PCa (csPCa).Methods a literature search was performed using the MEDLINE, EMBASE, Cochrane Library, ClinicalTrials.gov, and CINAHL databases. Studies evaluating SWE for the detection of PCa using histopathology as reference standard were included.Results 16 studies including 2277 patients were included for review. Nine studies evaluated SWE for the detection of PCa using systematic biopsy as a reference standard at the per-sample level, with a pooled sensitivity and specificity of 0.85 (95% CI = 0.74-0.92) and 0.85 (95% CI = 0.75-0.91), respectively. Five studies evaluated SWE for the detection of PCa using histopathology of radical prostatectomy (RP) specimens as the reference standard, with a pooled sensitivity and specificity of 0.71 (95% CI = 0.55-0.83) and 0.74 (95% CI = 0.42-0.92), respectively. Sub-group analysis revealed a higher pooled sensitivity (0.77 vs. 0.62) and specificity (0.84 vs. 0.53) for detection of csPCa compared to all PCa among studies using RP specimens as the reference standard.Conclusion SWE is an attractive imaging modality for the detection of PCa

    Antenna Near-Field Probe Station Scanner

    Get PDF
    A miniaturized antenna system is characterized non-destructively through the use of a scanner that measures its near-field radiated power performance. When taking measurements, the scanner can be moved linearly along the x, y and z axis, as well as rotationally relative to the antenna. The data obtained from the characterization are processed to determine the far-field properties of the system and to optimize the system. Each antenna is excited using a probe station system while a scanning probe scans the space above the antenna to measure the near field signals. Upon completion of the scan, the near-field patterns are transformed into far-field patterns. Along with taking data, this system also allows for extensive graphing and analysis of both the near-field and far-field data. The details of the probe station as well as the procedures for setting up a test, conducting a test, and analyzing the resulting data are also described

    Contrast-Enhanced Ultrasound-Guided Radiofrequency Ablation of Renal Tumo

    Get PDF
    Although only limited long-term studies evaluating thermal ablation of renal masses have been performed, it appears that thermal ablation has a comparable 5-year success rate to that of partial or total nephrectomy. This technique is often used in patients who are not good candidates for partial or total nephrectomy. Contrast-enhanced ultrasound (CEUS) has been recently approved by the Food and Drug Administration for characterization of focal liver lesions in adults and pediatric patients. CEUS can be used off label for renal applications and has been used for years in Europe and Asia. It has several advantages over contrast-enhanced computed tomography for use as the technique to guide and evaluate efficacy of thermal ablation of renal masses. These include the ability to visualize small amounts of enhancement, repeat dosing to evaluate efficacy of an ablation during a procedure, thin slice thickness, and real-time visualization. Ultrasound contrast is also non-nephrotoxic and non-hepatotoxic, allowing evaluation of patients with renal insufficiency. This article reviews the use of CEUS for the guidance and follow-up of thermal ablative procedures of renal masses

    Probe Station and Near-Field Scanner for Testing Antennas

    Get PDF
    A facility that includes a probe station and a scanning open-ended waveguide probe for measuring near electromagnetic fields has been added to Glenn Research Center's suite of antenna-testing facilities, at a small fraction of the cost of the other facilities. This facility is designed specifically for nondestructive characterization of the radiation patterns of miniaturized microwave antennas fabricated on semiconductor and dielectric wafer substrates, including active antennas that are difficult to test in traditional antenna-testing ranges because of fragility, smallness, or severity of DC-bias or test-fixture requirements. By virtue of the simple fact that a greater fraction of radiated power can be captured in a near-field measurement than in a conventional far-field measurement, this near-field facility is convenient for testing miniaturized antennas with low gains

    Effects of Environmental Agents on the Attainment of Puberty: Considerations When Assessing Exposure to Environmental Chemicals in the National Childrenā€™s Study

    Get PDF
    The apparent decline in the age at puberty in the United States raises a general level of concern because of the potential clinical and social consequences of such an event. Nutritional status, genetic predisposition (race/ethnicity), and environmental chemicals are associated with altered age at puberty. The Exposure to Chemical Agents Working Group of the National Childrenā€™s Study (NCS) presents an approach to assess exposure for chemicals that may affect the age of maturity in children. The process involves conducting the assessment by life stages (i.e., in utero, postnatal, peripubertal), adopting a general categorization of the environmental chemicals by biologic persistence, and collecting and storing biologic specimens that are most likely to yield meaningful information. The analysis of environmental samples and use of questionnaire data are essential in the assessment of chemicals that cannot be measured in biologic specimens, and they can assist in the evaluation of exposure to nonpersistent chemicals. Food and dietary data may be used to determine the extent to which nutrients and chemicals from this pathway contribute to the variance in the timing of puberty. Additional research is necessary in several of these areas and is ongoing. The NCS is uniquely poised to evaluate the effects of environmental chemicals on the age at puberty, and the above approach will allow the NCS to accomplish this task

    Tunable-filter imaging of quasar fields at z~1. I. A cluster around MRC B0450-221

    Get PDF
    Using a combination of multicolour broad- and narrow-band imaging techniques and follow-up spectroscopy, we have detected an overdensity of galaxies in the field of quasar MRC B0450-221, whose properties are consistent with a cluster at the quasar redshift z=0.9. An excess of red galaxies (V-I>2.2, I-K'>3.8) is evident within 1' of the quasar, with the colours expected for galaxies at z=0.9 that have evolved passively for 3 Gyr or more. A number of line-emitting galaxies (nine candidates with equivalent widths EW>70A) are also detected in the field using the TAURUS Tunable Filter (TTF). Three have been confirmed spectroscopically to indeed lie at z=0.9. The TTF candidates with the strongest [O II] line emission cluster in a group which lies 200-700 kpc away from the quasar and the red galaxy excess, and therefore most likely on the outskirts of the cluster. These observations are the first in a series probing quasar environments at z~1 with TTF.Comment: Accepted for publication in AJ. 25 pages, 24 figs (large files in jpg or gif format), uses emulateapj.st
    • ā€¦