476 research outputs found

    Associations of Retinal Microvascular Diameters and Tortuosity With Blood Pressure and Arterial Stiffness: United Kingdom Biobank.

    Get PDF
    To examine the baseline associations of retinal vessel morphometry with blood pressure (BP) and arterial stiffness in United Kingdom Biobank. The United Kingdom Biobank included 68 550 participants aged 40 to 69 years who underwent nonmydriatic retinal imaging, BP, and arterial stiffness index assessment. A fully automated image analysis program (QUARTZ [Quantitative Analysis of Retinal Vessel Topology and Size]) provided measures of retinal vessel diameter and tortuosity. The associations between retinal vessel morphology and cardiovascular disease risk factors/outcomes were examined using multilevel linear regression to provide absolute differences in vessel diameter and percentage differences in tortuosity (allowing within person clustering), adjusted for age, sex, ethnicity, clinic, body mass index, smoking, and deprivation index. Greater arteriolar tortuosity was associated with higher systolic BP (relative increase, 1.2%; 95% CI, 0.9; 1.4% per 10 mmHg), higher mean arterial pressure, 1.3%; 0.9, 1.7% per 10 mmHg, and higher pulse pressure (PP, 1.8%; 1.4; 2.2% per 10 mmHg). Narrower arterioles were associated with higher systolic BP (-0.9 µm; -0.94, -0.87 µm per 10 mmHg), mean arterial pressure (-1.5 µm; -1.5, -1.5 µm per 10 mmHg), PP (-0.7 µm; -0.8, -0.7 µm per 10 mmHg), and arterial stiffness index (-0.12 µm; -0.14, -0.09 µm per ms/m2). Associations were in the same direction but marginally weaker for venular tortuosity and diameter. This study assessing the retinal microvasculature at scale has shown clear associations between retinal vessel morphometry, BP, and arterial stiffness index. These observations further our understanding of the preclinical disease processes and interplay between microvascular and macrovascular disease

    Retinal Vascular Tortuosity and Diameter Associations with Adiposity and Components of Body Composition.

    Get PDF
    OBJECTIVE: The aim of this study was to assess whether adiposity or body composition relates to microvascular characteristics of the retina, indicative of cardiometabolic function. METHODS: A fully automated QUARTZ software processed retinal images from 68,550 UK Biobank participants (aged 40-69 years). Differences in retinal vessel diameter and tortuosity with body composition measures from the Tanita analyzer were obtained by using multilevel regression analyses adjusted for age, sex, ethnicity, clinic, smoking, and Townsend deprivation index. RESULTS: Venular tortuosity and diameter increased by approximately 2% (P < 10-300 ) and 0.6 μm (P < 10-6 ), respectively, per SD increase in BMI, waist circumference index, waist-hip ratio, total body fat mass index, and fat-free mass index (FFMI). Venular associations with adiposity persisted after adjustment for FFMI, whereas associations with FFMI were weakened by FMI adjustment. Arteriolar diameter (not tortuosity) narrowing with FFMI was independent of adiposity (-0.6 μm; -0.7 to -0.4 μm per SD increment of FFMI), while adiposity associations with arteriolar diameter were largely nonsignificant after adjustment for FFMI. CONCLUSIONS: This demonstrates, on an unprecedented scale, that venular tortuosity and diameter are more strongly associated with adiposity, whereas arteriolar diameter relates more strongly to fat-free mass. Different attributes of the retinal microvasculature may reflect distinct roles of body composition and fatness on the cardiometabolic system

    A freely accessible, evidence based, objective system of analysis of posterior capsular opacification ; Evidence for its validity and reliability

    Get PDF
    BACKGROUND: The aim of this study was to develop a system of computerised analysis of digital images of posterior capsule opacification (PCO) that is evidence based, objective and freely available. The paper will present evidence for the reliability and validity of the developed system. METHODS: The system of PCO analysis was developed considering current published evidence on visual significance of PCO and additional investigative analysis of PCO images. Details of the image processing and analysis steps are discussed and a final system that measures an entropy score weighted toward proximity to central areas is described. In order to assess validity, the systems ability to measure PCO progression is assessed along with the visual significance of its final computerised scores. Reliability of the system is also assessed. RESULTS: The final system runs successfully and is simple to use. Analyses of PCO by the system show an ability to detect early progression of PCO as well as detection of visually significant PCO. Images with no clinical PCO produce very low scores in the analysis. Reliability of the system of analysis is shown to be satisfactory. CONCLUSION: This paper presents a system of PCO analysis that is evidence based, objective and clinically useful. Substantial evidence is provided for its validity and reliability

    A collaborative comparison of Objective Structured Clinical Examination (OSCE) standard setting methods at Australian medical schools

    Get PDF
    Background: A key issue underpinning the usefulness of the OSCE assessment to medical education is standard-setting, but the majority of standard-setting methods remain challenging for performance assessment because they produce varying passing marks. Several studies have compared standard setting methods; however, most of these studies are limited by their experimental scope, or use data on examinee performance at a single OSCE station or from a single medical school. This collaborative study between ten Australian medical schools investigated the effect of standard-setting methods on OSCE cut scores and failure rates. Methods: This research used 5,256 examinee scores from seven shared OSCE stations to calculate cut scores and failure rates using two different compromise standard-setting methods, namely the Borderline Regression and Cohen's methods. Results: The results of this study indicate that Cohen's method yields similar outcomes to the Borderline Regression method, particularly for large examinee cohort sizes. However, with lower examinee numbers on a station, the Borderline Regression method resulted in higher cut scores and larger difference margins in the failure rates. Conclusion: Cohen's method yields similar outcomes as the Borderline Regression method and its application for benchmarking purposes and in resource-limited settings is justifiable, particularly with large examinee numbers

    Ethnic disparities in progression rates for sight-threatening diabetic retinopathy in diabetic eye screening: a population-based retrospective cohort study

    Get PDF
    INTRODUCTION: The English Diabetic Eye Screening Programme (DESP) offers people living with diabetes (PLD) annual eye screening. We examined incidence and determinants of sight-threatening diabetic retinopathy (STDR) in a sociodemographically diverse multi-ethnic population. RESEARCH DESIGN AND METHODS: North East London DESP cohort data (January 2012 to December 2021) with 137 591 PLD with no retinopathy, or non-STDR at baseline in one/both eyes, were used to calculate STDR incidence rates by sociodemographic factors, diabetes type, and duration. HR from Cox models examined associations with STDR. RESULTS: There were 16 388 incident STDR cases over a median of 5.4 years (IQR 2.8-8.2; STDR rate 2.214, 95% CI 2.214 to 2.215 per 100 person-years). People with no retinopathy at baseline had a lower risk of sight-threatening diabetic retinopathy (STDR) compared with those with non-STDR in one eye (HR 3.03, 95% CI 2.91 to 3.15, p<0.001) and both eyes (HR 7.88, 95% CI 7.59 to 8.18, p<0.001). Black and South Asian individuals had higher STDR hazards than white individuals (HR 1.57, 95% CI 1.50 to 1.64 and HR 1.36, 95% CI 1.31 to 1.42, respectively). Additionally, every 5-year increase in age at inclusion was associated with an 8% reduction in STDR hazards (p<0.001). CONCLUSIONS: Ethnic disparities exist in a health system limited by capacity rather than patient economic circumstances. Diabetic retinopathy at first screen is a strong determinant of STDR development. By using basic demographic characteristics, screening programmes or clinical practices can stratify risk for sight-threatening diabetic retinopathy development

    OSCA: a comprehensive open-access system of analysis of posterior capsular opacification

    Get PDF
    BACKGROUND: This paper presents and tests a comprehensive computerised system of analysis of digital images of posterior capsule opacification (PCO). It updates and expands significantly on a previous presentation to include facilities for selecting user defined central areas and for registering and subsequent merging of images for artefact removal. Also, the program is compiled and thus eliminates the need for specialised additional software. The system is referred to in this paper as the open-access systematic capsule assessment (OSCA). The system is designed to be evidence based, objective and openly available, improving on current systems of analysis. METHODS: Principal features of the OSCA system of analysis are discussed. Flash artefacts are automatically located in two PCO images and the images merged to produce a composite free from these artefacts. For this to be possible the second image has to be manipulated with a registration technique to bring it into alignment with the first. Further image processing and analysis steps use a location-sensitive entropy based texture analysis of PCO. Validity of measuring PCO progression of the whole new system is assessed along with visual significance of scores. Reliability of the system is assessed. RESULTS: Analysis of PCO by the system shows ability to detect early progression of PCO, as well as detection of more visually significant PCO. Images with no clinical PCO produce very low scores in the analysis. Reliability of the system of analysis is demonstrated. CONCLUSION: This system of PCO analysis is evidence-based, objective and clinically useful. It incorporates flash detection and removal as well as location sensitive texture analysis. It provides features and benefits not previously available to most researchers or clinicians. Substantial evidence is provided for this system's validity and reliability

    Portable Optical Fiber Probe-Based Spectroscopic Scanner for Rapid Cancer Diagnosis: A New Tool for Intraoperative Margin Assessment

    Get PDF
    There continues to be a significant clinical need for rapid and reliable intraoperative margin assessment during cancer surgery. Here we describe a portable, quantitative, optical fiber probe-based, spectroscopic tissue scanner designed for intraoperative diagnostic imaging of surgical margins, which we tested in a proof of concept study in human tissue for breast cancer diagnosis. The tissue scanner combines both diffuse reflectance spectroscopy (DRS) and intrinsic fluorescence spectroscopy (IFS), and has hyperspectral imaging capability, acquiring full DRS and IFS spectra for each scanned image pixel. Modeling of the DRS and IFS spectra yields quantitative parameters that reflect the metabolic, biochemical and morphological state of tissue, which are translated into disease diagnosis. The tissue scanner has high spatial resolution (0.25 mm) over a wide field of view (10 cm×10 cm), and both high spectral resolution (2 nm) and high spectral contrast, readily distinguishing tissues with widely varying optical properties (bone, skeletal muscle, fat and connective tissue). Tissue-simulating phantom experiments confirm that the tissue scanner can quantitatively measure spectral parameters, such as hemoglobin concentration, in a physiologically relevant range with a high degree of accuracy (<5% error). Finally, studies using human breast tissues showed that the tissue scanner can detect small foci of breast cancer in a background of normal breast tissue. This tissue scanner is simpler in design, images a larger field of view at higher resolution and provides a more physically meaningful tissue diagnosis than other spectroscopic imaging systems currently reported in literatures. We believe this spectroscopic tissue scanner can provide real-time, comprehensive diagnostic imaging of surgical margins in excised tissues, overcoming the sampling limitation in current histopathology margin assessment. As such it is a significant step in the development of a platform technology for intraoperative management of cancer, a clinical problem that has been inadequately addressed to date.Case Comprehensive Cancer Center. Tissue Procurement, Histology and Immunohistochemistry Core Facility (P30 CA43703)National Cancer Institute (U.S.) (R01-CA140288)National Cancer Institute (U.S.) (R01-CA97966)National Center for Research Resources (U.S.) (S10-RR031845)National Center for Research Resources (U.S.) (P41-RR02594

    Steady-state modulation of voltage-gated K+ channels in rat arterial smooth muscle by cyclic AMP-dependent protein kinase and protein phosphatase 2B

    Get PDF
    Voltage-gated potassium channels (Kv) are important regulators of membrane potential in vascular smooth muscle cells, which is integral to controlling intracellular Ca2+ concentration and regulating vascular tone. Previous work indicates that Kv channels can be modulated by receptor-driven alterations of cyclic AMP-dependent protein kinase (PKA) activity. Here, we demonstrate that Kv channel activity is maintained by tonic activity of PKA. Whole-cell recording was used to assess the effect of manipulating PKA signalling on Kv and ATP-dependent K+ channels of rat mesenteric artery smooth muscle cells. Application of PKA inhibitors, KT5720 or H89, caused a significant inhibition of Kv currents. Tonic PKA-mediated activation of Kv appears maximal as application of isoprenaline (a β-adrenoceptor agonist) or dibutyryl-cAMP failed to enhance Kv currents. We also show that this modulation of Kv by PKA can be reversed by protein phosphatase 2B/calcineurin (PP2B). PKA-dependent inhibition of Kv by KT5720 can be abrogated by pre-treatment with the PP2B inhibitor cyclosporin A, or inclusion of a PP2B auto-inhibitory peptide in the pipette solution. Finally, we demonstrate that tonic PKA-mediated modulation of Kv requires intact caveolae. Pre-treatment of the cells with methyl-β-cyclodextrin to deplete cellular cholesterol, or adding caveolin-scaffolding domain peptide to the pipette solution to disrupt caveolae-dependent signalling each attenuated PKA-mediated modulation of the Kv current. These findings highlight a novel, caveolae-dependent, tonic modulatory role of PKA on Kv channels providing new insight into mechanisms and the potential for pharmacological manipulation of vascular tone
    • …
    corecore