4 research outputs found

    Hemodynamic Disorders Related To Beating Heart Surgery Using Cardiac Stabilizers: Experimental Study.

    Get PDF
    To study in swine the hemodynamic changes secondary to the use of stabilizers for off-pump coronary artery bypass graft surgeries by means of both a suction device Octopus and a compression device (Speroni). Ten swine underwent median sternotomy. Monitoring of ECG, continuous cardiac output, mean arterial pressure, mean pulmonary artery pressure, mean right and left atrial pressures, and right and left ventricular diastolic pressure were performed. Stroke volume and systemic vascular resistance were calculated. Both stabilizers were studied placed on three vessels: anterior interventricular branch, posterior interventricular branch, and marginal branch of the circumflex branch. Each animal was randomly designed to application regarding the type of stabilizer and the target artery. The measurements were carried out 5 minutes before and after the stabilizer application. In the anterior interventricular branch changes have occurred only with the compression device, thus reducing cardiac output, stroke volume, and mean arterial pressure, but increasing the systemic vascular resistance. In the posterior interventricular branch changes have occurred with the compression device (Speroni), reducing cardiac output and stroke volume, but increasing the heart rate. With the suction device (octopus) there was an increase of both heart rate and systemic vascular resistance, but a decrease in stroke volume. In the marginal branch of the circumflex branch there was a decrease of cardiac output, stroke volume, and mean arterial pressure with both stabilizers. Also, there was a decrease in the mean pulmonary artery pressure and an increase in the mean right atrial pressure with the compression device (Speroni). Both stabilizers have caused hemodynamic changes. The compression device (Speroni) is more associated with changes than the suction device (Octopus).22407-1

    Alterações hemodinâmicas devido ao uso de estabilizadores em revascularização do miocárdio: estudo experimental Hemodynamic disorders related to beating heart surgery using cardiac stabilizers: experimental study

    No full text
    OBJETIVO: Estudar, em suínos, as alterações hemodinâmicas secundárias ao uso de estabilizadores para operações de revascularização do miocárdio sem circulação extracorpórea, um por sucção (Octopus) e outro por compressão (Speroni). MÉTODOS: Dez suínos submetidos à esternotomia e monitorizados com eletrocardiograma, débito cardíaco contínuo e pressões: arterial média, pulmonar média, atriais médias direita e esquerda, ventriculares diastólicas direita e esquerda, calculando-se volume sistólico e resistência vascular sistêmica. Estudaram-se os estabilizadores posicionados em três artérias: interventricular anterior, interventricular posterior e ramo marginal da circunflexa. Para cada animal foi sorteada a ordem de aplicação do estabilizador com relação ao tipo e à artéria. As mensurações foram realizadas antes e após aplicar-se o estabilizador. RESULTADOS: Na artéria interventricular anterior, ocorreram alterações somente com o Speroni, havendo queda do débito cardíaco, do volume sistólico e da pressão arterial média, com aumento da resistência vascular sistêmica. Na artéria interventricular posterior, constatamos alterações com o Speroni, havendo queda do débito cardíaco e do volume sistólico, com aumento da freqüência cardíaca. Com o Octopus houve aumento da freqüência cardíaca e da resistência vascular sistêmica, com queda do volume sistólico. No ramo marginal da circunflexa, ocorreu queda do débito cardíaco, do volume sistólico e da pressão arterial média com os dois estabilizadores, havendo também queda na pressão arterial pulmonar média e aumento da pressão atrial direita média com o estabilizador por compressão. CONCLUSÕES: Ambos os estabilizadores causaram alterações hemodinâmicas. O que atua por compressão provocou mais alterações do que o que atua por sucção.<br>OBJECTIVE: To study in swine the hemodynamic changes secondary to the use of stabilizers for off-pump coronary artery bypass graft surgeries by means of both a suction device "Octopus" and a compression device (Speroni). METHODS: Ten swine underwent median sternotomy. Monitoring of ECG, continuous cardiac output, mean arterial pressure, mean pulmonary artery pressure, mean right and left atrial pressures, and right and left ventricular diastolic pressure were performed. Stroke volume and systemic vascular resistance were calculated. Both stabilizers were studied placed on three vessels: anterior interventricular branch, posterior interventricular branch, and marginal branch of the circumflex branch. Each animal was randomly designed to application regarding the type of stabilizer and the target artery. The measurements were carried out 5 minutes before and after the stabilizer application. RESULTS: In the anterior interventricular branch changes have occurred only with the compression device, thus reducing cardiac output, stroke volume, and mean arterial pressure, but increasing the systemic vascular resistance. In the posterior interventricular branch changes have occurred with the compression device (Speroni), reducing cardiac output and stroke volume, but increasing the heart rate. With the suction device (octopus) there was an increase of both heart rate and systemic vascular resistance, but a decrease in stroke volume. In the marginal branch of the circumflex branch there was a decrease of cardiac output, stroke volume, and mean arterial pressure with both stabilizers. Also, there was a decrease in the mean pulmonary artery pressure and an increase in the mean right atrial pressure with the compression device (Speroni). CONCLUSION: Both stabilizers have caused hemodynamic changes. The compression device (Speroni) is more associated with changes than the suction device (Octopus)

    Implementation of a Brazilian Cardioprotective Nutritional (BALANCE) Program for improvement on quality of diet and secondary prevention of cardiovascular events: A randomized, multicenter trial

    Get PDF
    Background: Appropriate dietary recommendations represent a key part of secondary prevention in cardiovascular disease (CVD). We evaluated the effectiveness of the implementation of a nutritional program on quality of diet, cardiovascular events, and death in patients with established CVD. Methods: In this open-label, multicenter trial conducted in 35 sites in Brazil, we randomly assigned (1:1) patients aged 45 years or older to receive either the BALANCE Program (experimental group) or conventional nutrition advice (control group). The BALANCE Program included a unique nutritional education strategy to implement recommendations from guidelines, adapted to the use of affordable and regional foods. Adherence to diet was evaluated by the modified Alternative Healthy Eating Index. The primary end point was a composite of all-cause mortality, cardiovascular death, cardiac arrest, myocardial infarction, stroke, myocardial revascularization, amputation, or hospitalization for unstable angina. Secondary end points included biochemical and anthropometric data, and blood pressure levels. Results: From March 5, 2013, to Abril 7, 2015, a total of 2534 eligible patients were randomly assigned to either the BALANCE Program group (n = 1,266) or the control group (n = 1,268) and were followed up for a median of 3.5 years. In total, 235 (9.3%) participants had been lost to follow-up. After 3 years of follow-up, mean modified Alternative Healthy Eating Index (scale 0-70) was only slightly higher in the BALANCE group versus the control group (26.2 ± 8.4 vs 24.7 ± 8.6, P <.01), mainly due to a 0.5-serving/d greater intake of fruits and of vegetables in the BALANCE group. Primary end point events occurred in 236 participants (18.8%) in the BALANCE group and in 207 participants (16.4%) in the control group (hazard ratio, 1.15; 95% CI 0.95-1.38; P =.15). Secondary end points did not differ between groups after follow-up. Conclusions: The BALANCE Program only slightly improved adherence to a healthy diet in patients with established CVD and had no significant effect on the incidence of cardiovascular events or death. © 2019 The Author

    Resumos concluídos - Saúde Coletiva

    No full text
    Resumos concluídos - Saúde Coletiv
    corecore