15,024 research outputs found
Turbofan forced mixer lobe flow modeling. Part 3: Application to augment engines
Military engines frequently need large quantities of thrust for short periods of time. The addition of an augmentor can provide such thrust increases but with a penalty of increased duct length and engine weight. The addition of a forced mixer to the augmentor improves performance and reduces the penalty, as well as providing a method for siting the required flame holders. In this report two augmentor concepts are investigated: a swirl-mixer augmentor and a mixer-flameholder augmentor. Several designs for each concept are included and an experimental assessment of one of the swirl-mixer augmentors is presented
The Sound of Sonoluminescence
We consider an air bubble in water under conditions of single bubble
sonoluminescence (SBSL) and evaluate the emitted sound field nonperturbatively
for subsonic gas-liquid interface motion. Sound emission being the dominant
damping mechanism, we also implement the nonperturbative sound damping in the
Rayleigh-Plesset equation for the interface motion. We evaluate numerically the
sound pulse emitted during bubble collapse and compare the nonperturbative and
perturbative results, showing that the usual perturbative description leads to
an overestimate of the maximal surface velocity and maximal sound pressure. The
radius vs. time relation for a full SBSL cycle remains deceptively unaffected.Comment: 25 pages; LaTex and 6 attached ps figure files. Accepted for
publication in Physical Review
Flight evaluation of advanced control systems and displays on a general aviation airplane
A flight-test program was conducted to determine the effect of advanced flight control systems and displays on the handling qualities of a light twin-engined airplane. A flight-director display and an attitude-command control system, used separately and in combination, transformed a vehicle with poor handling qualities during ILS approaches in turbulent air into a vehicle with good handling qualities. The attitude-command control system also improved the ride qualities of the airplane. A rate-command control system made only small improvements to the airplane's ILS handling qualities in turbulence. Both the rate- and the attitude-command control systems reduced stall warning in the test airplane, increasing the likelihood of inadvertent stalls. The final approach to the point of flare was improved by both the rate- and the attitude-command control systems. However, the small control wheel deflections necessary to flare were unnatural and tended to cause overcontrolling during flare. Airplane handling qualities are summarized for each control-system and display configuration
Impact and Cost-Effectiveness of Point-Of-Care CD4 Testing on the HIV Epidemic in South Africa.
Rapid diagnostic tools have been shown to improve linkage of patients to care. In the context of infectious diseases, assessing the impact and cost-effectiveness of such tools at the population level, accounting for both direct and indirect effects, is key to informing adoption of these tools. Point-of-care (POC) CD4 testing has been shown to be highly effective in increasing the proportion of HIV positive patients who initiate ART. We assess the impact and cost-effectiveness of introducing POC CD4 testing at the population level in South Africa in a range of care contexts, using a dynamic compartmental model of HIV transmission, calibrated to the South African HIV epidemic. We performed a meta-analysis to quantify the differences between POC and laboratory CD4 testing on the proportion linking to care following CD4 testing. Cumulative infections averted and incremental cost-effectiveness ratios (ICERs) were estimated over one and three years. We estimated that POC CD4 testing introduced in the current South African care context can prevent 1.7% (95% CI: 0.4% - 4.3%) of new HIV infections over 1 year. In that context, POC CD4 testing was cost-effective 99.8% of the time after 1 year with a median estimated ICER of US$4,468/DALY averted. In healthcare contexts with expanded HIV testing and improved retention in care, POC CD4 testing only became cost-effective after 3 years. The results were similar when, in addition, ART was offered irrespective of CD4 count, and CD4 testing was used for clinical assessment. Our findings suggest that even if ART is expanded to all HIV positive individuals and HIV testing efforts are increased in the near future, POC CD4 testing is a cost-effective tool, even within a short time horizon. Our study also illustrates the importance of evaluating the potential impact of such diagnostic technologies at the population level, so that indirect benefits and costs can be incorporated into estimations of cost-effectiveness
Sonoluminescence as Quantum Vaccum Radiation
We argue that the available experimental data is not compatible with models
of sonoluminescence which invoke dynamical properties of the interface without
regard to the compositional properties of the trapped gas inside the bubble.Comment: 2 pages,Revtex,No figures,Submitted to PRL(comments
Three Dimensional Electrical Impedance Tomography
The electrical resistivity of mammalian tissues varies widely and is correlated with physiological
function. Electrical impedance tomography (EIT) can be used to probe such variations in vivo, and offers a
non-invasive means of imaging the internal conductivity distribution of the human body. But the
computational complexity of EIT has severe practical limitations, and previous work has been restricted to
considering image reconstruction as an essentially two-dimensional problem. This simplification can limit
significantly the imaging capabilities of EIT, as the electric currents used to determine the conductivity variations will not in general be confined to a two-dimensional plane. A few studies have attempted three-dimensional EIT image reconstruction, but have not yet succeeded in generating images of a quality suitable for clinical applications. Here we report the development of a three-dimensional EIT system with greatly improved imaging capabilities, which combines our 64-electrode data-collection apparatus with customized matrix inversion techniques. Our results demonstrate the practical potential of EIT for clinical applications, such as lung or brain imaging and diagnostic screening
Bubble Shape Oscillations and the Onset of Sonoluminescence
An air bubble trapped in water by an oscillating acoustic field undergoes
either radial or nonspherical pulsations depending on the strength of the
forcing pressure. Two different instability mechanisms (the Rayleigh--Taylor
instability and parametric instability) cause deviations from sphericity.
Distinguishing these mechanisms allows explanation of many features of recent
experiments on sonoluminescence, and suggests methods for finding
sonoluminescence in different parameter regimes.Comment: Phys. Rev. Lett., in pres
Gauge Theories with Cayley-Klein and Gauge Groups
Gauge theories with the orthogonal Cayley-Klein gauge groups and
are regarded. For nilpotent values of the contraction
parameters these groups are isomorphic to the non-semisimple Euclid,
Newton, Galilei groups and corresponding matter spaces are fiber spaces with
degenerate metrics. It is shown that the contracted gauge field theories
describe the same set of fields and particle mass as gauge
theories, if Lagrangians in the base and in the fibers all are taken into
account. Such theories based on non-semisimple contracted group provide more
simple field interactions as compared with the initial ones.Comment: 14 pages, 5 figure
Universal transport in 2D granular superconductors
The transport properties of quench condensed granular superconductors are
presented and analyzed. These systems exhibit transitions from insulating to
superconducting behavior as a function of inter-grain spacing.
Superconductivity is characterized by broad transitions in which the resistance
drops exponentially with reducing temperature. The slope of the log R versus T
curves turns out to be universaly dependent on the normal state film resistance
for all measured granular systems. It does not depend on the material, critical
temperature, geometry, or experimental set-up. We discuss possible physical
scenarios to explain these findings.Comment: 4 pages, 3 figure
- …