242 research outputs found

    Spectral Dependence of Coherent Backscattering of Light in a Narrow-Resonance Atomic System

    Get PDF
    We report a combined theoretical and experimental study of the spectral and polarization dependence of near resonant radiation coherently backscattered from an ultracold gas of 85Rb atoms. Measurements in an approximately 6 MHz range about the 5s^{2}S_{1/2}- 5p^{2}P_{3/2}, F=3 - F'=4 hyperfine transition are compared with simulations based on a realistic model of the experimental atomic density distribution. In the simulations, the influence of heating of the atoms in the vapor, magnetization of the vapor, finite spectral bandwidth, and other nonresonant hyperfine transitions are considered. Good agreement is found between the simulations and measurements.Comment: 10 pages, 12 figur

    Measurement of Correlated Multiple Light Scattering in Utracold Atomic \u3csup\u3e85\u3c/sup\u3eRb

    Get PDF
    We report an experimental study of correlated multiple light scattering in an ultracold gas of 85Rb confined in a magneto-optic trap. Measurements are made of the polarization dependence of the spatial and spectral profile of light backscattered from the sample. The results show an interferometric enhancement sensitive to coherent multiple scattering in the atomic gas, and strong variations with the polarization of the incident and detected light. The spatial width and peak value of the enhancement are found to be dependent on the sample size. Comparison of all the measurements with realistic quantum Monte Carlo simulations yields a very good agreeme

    Alignment Dynamics of Slow Light Diffusion in Ultracold Atomic \u3csup\u3e85\u3c/sup\u3eRb

    Get PDF
    A combined experimental and theoretical investigation of time- and alignment-dependent propagation of light in an ultracold atomic gas of atomic 85Rb is reported. Coherences among the scattering amplitudes for light scattering off excited hyperfine levels produce strong variations of the light polarization in the vicinity of atomic resonance. Measurements are in excellent agreement with Monte Carlo simulations of the multiple scattering process

    Huddle test measurement of a near Johnson noise limited geophone

    Get PDF
    In this paper, the sensor noise of two geophone configurations (L-22D and L-4C geophones from Sercel with custom built amplifiers) was measured by performing two huddle tests. It is shown that the accuracy of the results can be significantly improved by performing the huddle test in a seismically quiet environment and by using a large number of reference sensors to remove the seismic foreground signal from the data. Using these two techniques, the measured sensor noise of the two geophone configurations matched the calculated predictions remarkably well in the bandwidth of interest (0.01 Hz–100 Hz). Low noise operational amplifiers OPA188 were utilized to amplify the L-4C geophone to give a sensor that was characterized to be near Johnson noise limited in the bandwidth of interest with a noise value of 10−11 m/Hz⎯⎯⎯⎯⎯√10−11 m/Hz at 1 Hz

    Systematic review and literature appraisal on methodology of conducting and reporting critical-care echocardiography studies: a report from the European Society of Intensive Care Medicine PRICES expert panel

    Get PDF
    © 2020, The Author(s). Background: The echocardiography working group of the European Society of Intensive Care Medicine recognized the need to provide structured guidance for future CCE research methodology and reporting based on a systematic appraisal of the current literature. Here is reported this systematic appraisal. Methods: We conducted a systematic review, registered on the Prospero database. A total of 43 items of common interest to all echocardiography studies were initially listed by the experts, and other “topic-specific” items were separated into five main categories of interest (left ventricular systolic function, LVSF n = 15, right ventricular function, RVF n = 18, left ventricular diastolic function, LVDF n = 15, fluid management, FM n = 7, and advanced echocardiography techniques, AET n = 17). We evaluated the percentage of items reported per study and the fraction of studies reporting a single item. Results: From January 2000 till December 2017 a total of 209 articles were included after systematic search and screening, 97 for LVSF, 48 for RVF, 51 for LVDF, 36 for FM and 24 for AET. Shock and ARDS were relatively common among LVSF articles (both around 15%) while ARDS comprised 25% of RVF articles. Transthoracic echocardiography was the main echocardiography mode, in 87% of the articles for AET topic, followed by 81% for FM, 78% for LVDF, 70% for LVSF and 63% for RVF. The percentage of items per study as well as the fraction of study reporting an item was low or very low, except for FM. As an illustration, the left ventricular size was only reported by 56% of studies in the LVSF topic, and half studies assessing RVF reported data on pulmonary artery systolic pressure. Conclusion: This analysis confirmed sub-optimal reporting of several items listed by an expert panel. The analysis will help the experts in the development of guidelines for CCE study design and reporting

    RNA secondary structure prediction from multi-aligned sequences

    Full text link
    It has been well accepted that the RNA secondary structures of most functional non-coding RNAs (ncRNAs) are closely related to their functions and are conserved during evolution. Hence, prediction of conserved secondary structures from evolutionarily related sequences is one important task in RNA bioinformatics; the methods are useful not only to further functional analyses of ncRNAs but also to improve the accuracy of secondary structure predictions and to find novel functional RNAs from the genome. In this review, I focus on common secondary structure prediction from a given aligned RNA sequence, in which one secondary structure whose length is equal to that of the input alignment is predicted. I systematically review and classify existing tools and algorithms for the problem, by utilizing the information employed in the tools and by adopting a unified viewpoint based on maximum expected gain (MEG) estimators. I believe that this classification will allow a deeper understanding of each tool and provide users with useful information for selecting tools for common secondary structure predictions.Comment: A preprint of an invited review manuscript that will be published in a chapter of the book `Methods in Molecular Biology'. Note that this version of the manuscript may differ from the published versio

    The LBNO long-baseline oscillation sensitivities with two conventional neutrino beams at different baselines

    Get PDF
    The proposed Long Baseline Neutrino Observatory (LBNO) initially consists of 20\sim 20 kton liquid double phase TPC complemented by a magnetised iron calorimeter, to be installed at the Pyh\"asalmi mine, at a distance of 2300 km from CERN. The conventional neutrino beam is produced by 400 GeV protons accelerated at the SPS accelerator delivering 700 kW of power. The long baseline provides a unique opportunity to study neutrino flavour oscillations over their 1st and 2nd oscillation maxima exploring the L/EL/E behaviour, and distinguishing effects arising from δCP\delta_{CP} and matter. In this paper we show how this comprehensive physics case can be further enhanced and complemented if a neutrino beam produced at the Protvino IHEP accelerator complex, at a distance of 1160 km, and with modest power of 450 kW is aimed towards the same far detectors. We show that the coupling of two independent sub-MW conventional neutrino and antineutrino beams at different baselines from CERN and Protvino will allow to measure CP violation in the leptonic sector at a confidence level of at least 3σ3\sigma for 50\% of the true values of δCP\delta_{CP} with a 20 kton detector. With a far detector of 70 kton, the combination allows a 3σ3\sigma sensitivity for 75\% of the true values of δCP\delta_{CP} after 10 years of running. Running two independent neutrino beams, each at a power below 1 MW, is more within today's state of the art than the long-term operation of a new single high-energy multi-MW facility, which has several technical challenges and will likely require a learning curve.Comment: 21 pages, 12 figure

    Echocardiography findings in COVID-19 patients admitted to intensive care units: a multi-national observational study (the ECHO-COVID study)

    Get PDF
    Purpose: Severely ill patients affected by coronavirus disease 2019 (COVID-19) develop circulatory failure. We aimed to report patterns of left and right ventricular dysfunction in the first echocardiography following admission to intensive care unit (ICU). Methods: Retrospective, descriptive study that collected echocardiographic and clinical information from severely ill COVID-19 patients admitted to 14 ICUs in 8 countries. Patients admitted to ICU who received at least one echocardiography between 1st February 2020 and 30th June 2021 were included. Clinical and echocardiographic data were uploaded using a secured web-based electronic database (REDCap). Results: Six hundred and seventy-seven patients were included and the first echo was performed 2 [1, 4] days after ICU admission. The median age was 65 [56, 73] years, and 71% were male. Left ventricle (LV) and/or right ventricle (RV) systolic dysfunction were found in 234 (34.5%) patients. 149 (22%) patients had LV systolic dysfunction (with or without RV dysfunction) without LV dilatation and no elevation in filling pressure. 152 (22.5%) had RV systolic dysfunction. In 517 patients with information on both paradoxical septal motion and quantitative RV size, 90 (17.4%) had acute cor pulmonale (ACP). ACP was associated with mechanical ventilation (OR > 4), pulmonary embolism (OR > 5) and increased PaCO2. Exploratory analyses showed that patients with ACP and older age were more likely to die in hospital (including ICU). Conclusion: Almost one-third of this cohort of critically ill COVID-19 patients exhibited abnormal LV and/or RV systolic function in their first echocardiography assessment. While LV systolic dysfunction appears similar to septic cardiomyopathy, RV systolic dysfunction was related to pressure overload due to positive pressure ventilation, hypercapnia and pulmonary embolism. ACP and age seemed to be associated with mortality in this cohort
    corecore