6 research outputs found

    Value of the surgeon’s sightline on hologram registration and targeting in mixed reality

    No full text
    Purpose Mixed reality (MR) is being evaluated as a visual tool for surgical navigation. Current literature presents unclear results on intraoperative accuracy using the Microsoft HoloLens 1®. This study aims to assess the impact of the surgeon’s sightline in an inside-out marker-based MR navigation system for open surgery. Methods Surgeons at Akershus University Hospital tested this system. A custom-made phantom was used, containing 18 wire target crosses within its inner walls. A CT scan was obtained in order to segment all wire targets into a single 3D-model (hologram). An in-house software application (CTrue), developed for the Microsoft HoloLens 1, uploaded 3D-models and automatically registered the 3D-model with the phantom. Based on the surgeon’s sightline while registering and targeting (free sightline /F/or a strictly perpendicular sightline /P/), 4 scenarios were developed (FF-PF-FP-PP). Target error distance (TED) was obtained in three different working axes-(XYZ). Results Six surgeons (5 males, age 29–62) were enrolled. A total of 864 measurements were collected in 4 scenarios, twice. Scenario PP showed the smallest TED in XYZ-axes mean = 2.98 mm±SD 1.33; 2.28 mm±SD 1.45; 2.78 mm±SD 1.91, respectively. Scenario FF showed the largest TED in XYZ-axes with mean = 10.03 mm±SD 3.19; 6.36 mm±SD 3.36; 16.11 mm±SD 8.91, respectively. Multiple comparison tests, grouped in scenarios and axes, showed that the majority of scenario comparisons had significantly different TED values (p <0.05). Y-axis always presented the smallest TED regardless of scenario tested. Conclusion A strictly perpendicular working sightline in relation to the 3D-model achieves the best accuracy results. Shortcomings in this technology, as an intraoperative visual cue, can be overcome by sightline correction. Incidentally, this is the preferred working angle for open surgery

    Right Colectomy with Extended D3 Mesenterectomy: Anterior and Posterior to the Mesenteric Vessels

    No full text
    BACKGROUND: In right colectomy for cancer, complete mesocolic excision and D3 lymphadenectomy each leave behind lymphatic tissue anterior and posterior to the superior mesenteric vein (SMV) and artery (SMA). In this article, we present D3 extended mesenterectomy: a surgical technique that excises the lymphatic tissue en bloc with the right colectomy specimen. MATERIAL AND METHODS: A 3D map of the mesentery of the right colon was reconstructed from staging CT-angiogram scans. The surgical technique of right colectomy with D3 extended mesenterectomy consisted of eight steps: 1) reveal the SMV and SMA; 2) isolate the ileocolic artery; 3) isolate the middle colic artery; 4) resolve the anterior mesenteric flap; 5) specimen de-vascularization; 6) colectomy; 7) resolve the posterior mesenteric flap; and 8) anastomosis. RESULTS: One-hundred-seventy-six patients (77 men) 66 years of age were operated upon from February 2011 to January 2017. There were 169 adenocarcinomas: 16.0% Stage I, 49.1% Stage II, 33.7% Stage III, 1.2% Stage IV. Tumor locations were 50.6% cecum, 41.5% ascending colon, 4.5% hepatic flexure, and 2.3% transverse colon. Mean operating time was 200 minutes, blood loss 273 ml, and length of stay 7.9 days. There were 9 anastomotic leakages and 15 reoperations. One patient underwent small bowel resection due to SMA tear. There was no postoperative mortality. The mean number of lymph nodes per specimen (40.9) was comprised of 27.1 in the D2 volume and 13.8 in the D3 volume. The mean number of metastatic lymph nodes was 1.2 in the D2 volume and 0.13 in D3. There were 7 patients with lymph node metastasis in D3, 2 of whom had node metastasis solely within D3. CONCLUSION: This study shows that 1.2% of patients would have been incorrectly diagnosed as Stage II if extended D3 mesenterectomy had not been performed. Similarly, lymph node metastases would have been left behind in 4.1% of patients if extended D3 mesenterectomy had not been performed

    Right colectomy with extended D3 mesenterectomy: anterior and posterior to the mesenteric vessels

    No full text
    BACKGROUND: In right colectomy for cancer, complete mesocolic excision and D3 lymphadenectomy each leave behind lymphatic tissue anterior and posterior to the superior mesenteric vein (SMV) and artery (SMA). In this article, we present D3 extended mesenterectomy: a surgical technique that excises the lymphatic tissue en bloc with the right colectomy specimen. MATERIAL AND METHODS: A 3D map of the mesentery of the right colon was reconstructed from staging CT-angiogram scans. The surgical technique of right colectomy with D3 extended mesenterectomy consisted of eight steps: 1) reveal the SMV and SMA; 2) isolate the ileocolic artery; 3) isolate the middle colic artery; 4) resolve the anterior mesenteric flap; 5) specimen de-vascularization; 6) colectomy; 7) resolve the posterior mesenteric flap; and 8) anastomosis. RESULTS: One-hundred-seventy-six patients (77 men) 66 years of age were operated upon from February 2011 to January 2017. There were 169 adenocarcinomas: 16.0% Stage I, 49.1% Stage II, 33.7% Stage III, 1.2% Stage IV. Tumor locations were 50.6% cecum, 41.5% ascending colon, 4.5% hepatic flexure, and 2.3% transverse colon. Mean operating time was 200 minutes, blood loss 273 ml, and length of stay 7.9 days. There were 9 anastomotic leakages and 15 reoperations. One patient underwent small bowel resection due to SMA tear. There was no postoperative mortality. The mean number of lymph nodes per specimen (40.9) was comprised of 27.1 in the D2 volume and 13.8 in the D3 volume. The mean number of metastatic lymph nodes was 1.2 in the D2 volume and 0.13 in D3. There were 7 patients with lymph node metastasis in D3, 2 of whom had node metastasis solely within D3. CONCLUSION: This study shows that 1.2% of patients would have been incorrectly diagnosed as Stage II if extended D3 mesenterectomy had not been performed. Similarly, lymph node metastases would have been left behind in 4.1% of patients if extended D3 mesenterectomy had not been performed

    Semi-automated vs. manual 3D reconstruction of central mesenteric vascular models: the surgeon’s verdict

    No full text
    Background 3D vascular anatomy roadmaps are currently being implemented for surgical planning and navigation. Quality of the reconstruction is critical. The aim of this article is to compare anatomical completeness of models produced by manual and semi-automatic segmentation. Methods CT-datasets from patients included in an ongoing trial, underwent 3D vascular reconstruction applying two different segmentation methods. This produced manually-segmented models (MSMs) and semi-automatically segmented models (SAMs) which underwent a paired comparison. Datasets were delivered for reconstruction in 4 batches of 6, of which only batch 4 contained patients with abnormal anatomy. Model completeness was assessed quantitatively using alignment and distance error indexes and qualitatively with systematic inspection. MSMs were the gold standard. Assessed vessels were those of interest to the surgeon performing D3-right colectomy. Results 24 CT-datasets (13 females, age 44–77) were used in a paired comparative analysis of 48 3D-models. Quantitatively, SAMs showed structural improvement from Batch 1 to 3. Batch 4, with abnormal vessels, showed the highest error-index values. Qualitatively, 91.7% of SAMs did not contain all mesenteric branches relevant to the surgeon. In SAMs, 1 (12.5%) right colic artery-RCA scored as a complete vessel. 3 (37.5%) RCAs scored as incomplete and 4 (50%) RCAs were absent. 6 (25%) of 24 middle colic arteries-MCA scored as complete vessels. 11 (45.8%) scored as incomplete while 7 (29.2%) MCAs were absent. 13 (54.2%) of 24 ileocolic arteries-ICA were complete vessels. 11 (45.8%) scored as incomplete. None (0%) were absent. Additionally, it was observed that 10 (41.7%) of SAMs contained all their jejunal arteries, when compared to MSMs. Calibers of “complete” vessels were significantly higher than in “missing” vessels (MCA p < 0.001, RCA p = 0.016, ICA p < 0.001, JAs p < 0.001). Conclusion Despite acceptable results from quantitative analysis, qualitative comparison indicates that semi-automatically generated 3D-models of the central mesenteric vasculature could cause considerable confusion at surgery

    Implementation of 3D printed superior mesenteric vascular models for surgical planning and/or navigation in right colectomy with extended D3 mesenterectomy: comparison of virtual and physical models to the anatomy found at surgery

    No full text
    Background Three-dimensional (3D) printing technology has recently been well approved as an emerging technology in various fields of medical education and practice; e.g., there are numerous studies evaluating 3D printouts of solid organs. Complex surgery such as extended mesenterectomy imposes a need to analyze also the accuracy of 3D printouts of more mobile and complex structures like the diversity of vascular arborization within the central mesentery. The objective of this study was to evaluate the linear dimensional anatomy landmark differences of the superior mesenteric artery and vein between (1) 3D virtual models, (2) 3D printouts, and (3) peroperative measurements. Methods The study included 22 patients from the ongoing prospective multicenter trial “Safe Radical D3 Right Hemicolectomy for Cancer through Preoperative Biphasic MDCT Angiography,” with preoperative CT and peroperative measurements. The patients were operated in Norway between January 2016 and 2017. Their CT datasets underwent 3D volume rendering and segmentation, and the virtual 3D model produced was then exported for stereolithography 3D printing. Results Four parameters were measured: distance between the origins of the ileocolic and the middle colic artery, distance between the termination of the gastrocolic trunk and the ileocolic vein, and the calibers of the middle colic and ileocolic arteries. The inter-arterial distance has proven a strong correlation between all the three modalities implied (Pearson’s coefficient 0.968, 0.956, 0.779, respectively), while inter-venous distances showed a weak correlation between peroperative measurements and both virtual and physical models. Conclusion This study showed acceptable dimensional inter-arterial correlations between 3D printed models, 3D virtual models and authentic soft tissue anatomy of the central mesenteric vessels, and weaker inter-venous correlations between all the models, reflecting the highly variable nature of veins in situ
    corecore