1,104 research outputs found

    Compliance of a cobalt chromium coronary stent alloy – the COVIS trial

    Get PDF
    BACKGROUND: Cobalt chromium coronary stents are increasingly being used in percutaneous coronary interventions. There are, however, no reliable data about the characteristics of unfolding and visibility of this stent alloy in vivo. The aim of this study is to compare cobalt chromium coronary stents with conventional stainless steel stents using intracoronary ultrasound. METHODS: Twenty de novo native coronary stenoses ≀ 20 mm in length (target vessel reference diameter ≄ 2.5 and ≀ 4.0 mm) received under sequential intracoronary ultrasound either a cobalt chromium stent (Multi-Link Vision(Âź); n = 10) or a stainless steel stent (Multi-Link Zeta(Âź); n = 10). RESULTS: For optimal unfolding, the cobalt chromium stent requires a higher balloon deployment pressure (13.90 ± 2.03 atm) than the stainless steel stent (11.50 ± 2.12 atm). Furthermore, the achieved target vessel diameter of the cobalt chromium stent (Visibility-Index QCA/IVUS Multi-Link Vision(Âź)1.13 / Multi-Link Zeta(Âź )1.04) is more easily overrated by Quantitative Coronary Analysis. CONCLUSION: These data indicate that stent material-specific recommendations for optimal implantation pressure and different stent material with an equal design should both be considered in interpreting QCA-analysis

    Improving corporate governance in state-owned corporations in China: which way forward?

    Get PDF
    This article discusses corporate governance in China. It outlines the basic agency problem in Chinese listed companies and questions the effectiveness of the current mechanisms employed to improve their standards of governance. Importantly, it considers alternative means through which corporate practice in China can be brought into line with international expectations and stresses the urgency with which this task must be tackled. It concludes that regulators in China must construct a corporate governance model which is compatible with its domestic setting and not rush to adopt governance initiatives modelled on those in cultures which are fundamentally different in the hope of also reproducing their success

    Prediction of preterm birth with and without preeclampsia using mid-pregnancy immune and growth-related molecular factors and maternal characteristics.

    Get PDF
    OBJECTIVE:To evaluate if mid-pregnancy immune and growth-related molecular factors predict preterm birth (PTB) with and without (±) preeclampsia. STUDY DESIGN:Included were 400 women with singleton deliveries in California in 2009-2010 (200 PTB and 200 term) divided into training and testing samples at a 2:1 ratio. Sixty-three markers were tested in 15-20 serum samples using multiplex technology. Linear discriminate analysis was used to create a discriminate function. Model performance was assessed using area under the receiver operating characteristic curve (AUC). RESULTS:Twenty-five serum biomarkers along with maternal age <34 years and poverty status identified >80% of women with PTB ± preeclampsia with best performance in women with preterm preeclampsia (AUC = 0.889, 95% confidence interval (0.822-0.959) training; 0.883 (0.804-0.963) testing). CONCLUSION:Together with maternal age and poverty status, mid-pregnancy immune and growth factors reliably identified most women who went on to have a PTB ± preeclampsia

    Advances in Nondietary Management of Children with Atopic Dermatitis

    Full text link
    This paper discusses recent advances in therapy of atopic dermatitis (AD), excluding those that include dietary management. Some of these therapies are anecdotal, experimental, or somewhat controversial. It is important to emphasize that physicians should not try what is new without first having given standard therapy a long and reasonable chance to succeed. This is important because AD does not last forever, and in many patients, mild disease heals spontaneously.Peer Reviewedhttp://deepblue.lib.umich.edu/bitstream/2027.42/72467/1/j.1525-1470.1989.tb00820.x.pd

    A Profile Likelihood Analysis of the Constrained MSSM with Genetic Algorithms

    Full text link
    The Constrained Minimal Supersymmetric Standard Model (CMSSM) is one of the simplest and most widely-studied supersymmetric extensions to the standard model of particle physics. Nevertheless, current data do not sufficiently constrain the model parameters in a way completely independent of priors, statistical measures and scanning techniques. We present a new technique for scanning supersymmetric parameter spaces, optimised for frequentist profile likelihood analyses and based on Genetic Algorithms. We apply this technique to the CMSSM, taking into account existing collider and cosmological data in our global fit. We compare our method to the MultiNest algorithm, an efficient Bayesian technique, paying particular attention to the best-fit points and implications for particle masses at the LHC and dark matter searches. Our global best-fit point lies in the focus point region. We find many high-likelihood points in both the stau co-annihilation and focus point regions, including a previously neglected section of the co-annihilation region at large m_0. We show that there are many high-likelihood points in the CMSSM parameter space commonly missed by existing scanning techniques, especially at high masses. This has a significant influence on the derived confidence regions for parameters and observables, and can dramatically change the entire statistical inference of such scans.Comment: 47 pages, 8 figures; Fig. 8, Table 7 and more discussions added to Sec. 3.4.2 in response to referee's comments; accepted for publication in JHE

    Mathematical Analysis of Copy Number Variation in a DNA Sample Using Digital PCR on a Nanofluidic Device

    Get PDF
    Copy Number Variations (CNVs) of regions of the human genome have been associated with multiple diseases. We present an algorithm which is mathematically sound and computationally efficient to accurately analyze CNV in a DNA sample utilizing a nanofluidic device, known as the digital array. This numerical algorithm is utilized to compute copy number variation and the associated statistical confidence interval and is based on results from probability theory and statistics. We also provide formulas which can be used as close approximations

    Comparison of two different physical activity monitors

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Understanding the relationships between physical activity (PA) and disease has become a major area of research interest. Activity monitors, devices that quantify free-living PA for prolonged periods of time (days or weeks), are increasingly being used to estimate PA. A range of different activity monitors brands are available for investigators to use, but little is known about how they respond to different levels of PA in the field, nor if data conversion between brands is possible.</p> <p>Methods</p> <p>56 women and men were fitted with two different activity monitors, the Actigraphℱ (Actigraph LLC; AGR) and the Acticalℱ (Mini-Mitter Co.; MM) for 15 days. Both activity monitors were fixed to an elasticized belt worn over the hip, with the anterior and posterior position of the activity monitors randomized. Differences between activity monitors and the validity of brand inter-conversion were measured by <it>t</it>-tests, Pearson correlations, Bland-Altman plots, and coefficients of variation (CV).</p> <p>Results</p> <p>The AGR detected a significantly greater amount of daily PA (216.2 ± 106.2 vs. 188.0 ± 101.1 counts/min, P < 0.0001). The average difference between activity monitors expressed as a CV were 3.1 and 15.5% for log-transformed and raw data, respectively. When a conversion equation was applied to convert datasets from one brand to another, the differences were no longer significant, with CV's of 2.2 and 11.7%, log-transformed and raw data, respectively.</p> <p>Conclusion</p> <p>Although activity monitors predict PA on the same scale (counts/min), the results between these two brands are not directly comparable. However, the data are comparable if a conversion equation is applied, with better results for log-transformed data.</p
    • 

    corecore