172 research outputs found

    Dark blood ischemic LGE segmentation using a deep learning approach

    Get PDF
    The extent of ischemic scar detected by Cardiac Magnetic Resonance (CMR) with late gadolinium enhancement (LGE) is linked with long-term prognosis, but scar quantification is time-consuming. Deep Learning (DL) approaches appear promising in CMR segmentation. Purpose: To train and apply a deep learning approach to dark blood (DB) CMR-LGE for ischemic scar segmentation, comparing results to 4-Standard Deviation (4-SD) semi-automated method. Methods: We trained and validated a dual neural network infrastructure on a dataset of DB-LGE short-axis stacks, acquired at 1.5T from 33 patients with ischemic scar. The DL architectures were an evolution of the U-Net Convolutional Neural Network (CNN), using data augmentation to increase generalization. The CNNs worked together to identify and segment 1) the myocardium and 2) areas of LGE. The first CNN simultaneously cropped the region of interest (RoI) according to the bounding box of the heart and calculated the area of myocardium. The cropped RoI was then processed by the second CNN, which identified the overall LGE area. The extent of scar was calculated as the ratio of the two areas. For comparison, endo- and epi-cardial borders were manually contoured and scars segmented by a 4-SD technique with a validated software. Results: The two U-Net networks were implemented with two free and open-source software library for machine learning. We performed 5-fold cross-validation over a dataset of 108 and 385 labelled CMR images of the myocardium and scar, respectively. We obtained high performance (> ∌0.85) as measured by the Intersection over Union metric (IoU) on the training sets, in the case of scar segmentation. With regards to heart recognition, the performance was lower (> ∌0.7), although improved (∌ 0.75) by detecting the cardiac area instead of heart boundaries. On the validation set, performances oscillated between 0.8 and 0.85 for scar tissue recognition, and dropped to ∌0.7 for myocardium segmentation. We believe that underrepresented samples and noise might be affecting the overall performances, so that additional data might be beneficial. Figure1: examples of heart segmentation (upper left panel: training; upper right panel: validation) and of scar segmentation (lower left panel: training; lower right panel: validation). Conclusion: Our CNNs show promising results in automatically segmenting LV and quantify ischemic scars on DB-LGE-CMR images. The performances of our method can further improve by expanding the data set used for the training. If implemented in a clinical routine, this process can speed up the CMR analysis process and aid in the clinical decision-making

    Effective Study: Development and Application of a Question-Driven, Time-Effective Cardiac Magnetic Resonance Scanning Protocol

    Get PDF
    BACKGROUND: Long scanning times impede cardiac magnetic resonance (CMR) clinical uptake. A “one‐size‐fits‐all” shortened, focused protocol (eg, only function and late‐gadolinium enhancement) reduces scanning time and costs, but provides less information. We developed 2 question‐driven CMR and stress‐CMR protocols, including tailored advanced tissue characterization, and tested their effectiveness in reducing scanning time while retaining the diagnostic performances of standard protocols. METHODS AND RESULTS: Eighty three consecutive patients with cardiomyopathy or ischemic heart disease underwent the tailored CMR. Each scan consisted of standard cines, late‐gadolinium enhancement imaging, native T1‐mapping, and extracellular volume. Fat/edema modules, right ventricle cine, and in‐line quantitative perfusion mapping were performed as clinically required. Workflow was optimized to avoid gaps. Time target was 30% (CMR: from 42±8 to 28±6 minutes; stress‐CMR: from 50±10 to 34±6 minutes, both P45% of cases. Quality grading was similar between the 2 protocols. Tailored protocols did not require additional staff. CONCLUSIONS: Tailored CMR and stress‐CMR protocols including advanced tissue characterization are accurate and time‐effective for cardiomyopathies and ischemic heart diseas

    Image Quality of Prospectively ECG-Triggered Coronary CT Angiography in Heart Transplant Recipients

    Get PDF
    OBJECTIVE: Cardiac allograft vasculopathy (CAV) is among the top causes of death 1 year after heart transplantation (HTx). Coronary CT angiography (CTA) is a potential alternative to invasive imaging in the diagnosis of CAV. However, the higher heart rate (HR) of HTx recipients prompts the use of retrospective ECG-gating, which is associated with higher radiation dose, a major concern in this patient population. Therefore, we sought to evaluate the feasibility and image quality of low-radiation-dose prospectively ECG-triggered coronary CTA in HTx recipients. MATERIALS AND METHODS: In total, 1270 coronary segments were evaluated in 50 HTx recipients and 50 matched control subjects who did not undergo HTx. The control subjects were selected from our clinical database and were matched for age, sex, body mass index, HR, and coronary dominance. Scans were performed using 256-MDCT with prospective ECG-triggering. The degree of motion artifacts was evaluated on a per-segment basis on a 4-point Likert-type scale. RESULTS: The median HR was 74.0 beats/min (interquartile range [IQR], 67.8-79.3 beats/min) in the HTx group and 73.0 beats/min (IQR, 68.5-80.0 beats/min) in the matched control group (p = 0.58). In the HTx group, more segments had diagnostic image quality compared with the control group (624/662 [94.3%] vs 504/608 [82.9%]; p < 0.001). The mean effective radiation dose was low in both groups (3.7 mSv [IQR, 2.4-4.3 mSv] in the HTx group vs 4.3 mSv [IQR, 2.6-4.3 mSv] in the control group; p = 0.24). CONCLUSION: Prospectively ECG-triggered coronary CTA examinations of HTx recipients yielded diagnostic image quality with low radiation dose. Coronary CTA is a promising noninvasive alternative to routine catheterization during follow-up of HTx recipients to diagnose CAV

    Echocardiographic assessment of the tricuspid and pulmonary valves.

    Get PDF
    Transthoracic echocardiography is the first-line imaging modality in the assessment of right-sided valve disease. The principle objectives of the echocardiographic study are to determine the aetiology, mechanism and severity of valvular dysfunction, as well as consequences on right heart remodelling and estimations of pulmonary artery pressure. Echocardiographic data must be integrated with symptoms, to inform optimal timing and technique of interventions. The most common tricuspid valve abnormality is regurgitation secondary to annular dilatation in the context of atrial fibrillation or left-sided heart disease. Significant pulmonary valve disease is most commonly seen in congenital heart abnormalities. The aetiology and mechanism of tricuspid and pulmonary valve disease can usually be identified by 2-dimensional assessment of leaflet morphology and motion. Colour flow and spectral Doppler are required for assessment of severity, which must integrate data from multiple imaging planes and modalities. Transoesophageal echo is used when transthoracic data is incomplete, although the anterior position of the right heart means that transthoracic imaging is often superior. Three-dimensional echocardiography is a pivotal tool for accurate quantification of right ventricular volumes and regurgitant lesion severity, anatomical characterisation of valve morphology and remodelling pattern, and procedural guidance for catheter-based interventions. Exercise echocardiography may be used to elucidate symptom status and demonstrate functional reserve. CMR and CT should be considered for complimentary data including right ventricular volume quantification, and precise cardiac and extracardiac anatomy. This BSE guideline aims to give practical advice on the standardised acquisition and interpretation of echocardiographic data relating to the pulmonary and tricuspid valves

    Quantification of the relative contribution of the different right ventricular wall motion components to right ventricular ejection fraction

    Get PDF
    Abstract Three major mechanisms contribute to right ventricular (RV) pump function: (i) shortening of the longitudinal axis with traction of the tricuspid annulus towards the apex; (ii) inward movement of the RV free wall; (iii) bulging of the interventricular septum into the RV and stretching the free wall over the septum. The relative contribution of the aforementioned mechanisms to RV pump function may change in different pathological conditions. Our aim was to develop a custom method to separately assess the extent of longitudinal, radial and anteroposterior displacement of the RV walls and to quantify their relative contribution to global RV ejection fraction using 3D data sets obtained by echocardiography. Accordingly, we decomposed the movement of the exported RV beutel wall in a vertex based manner. The volumes of the beutels accounting for the RV wall motion in only one direction (either longitudinal, radial, or anteroposterior) were calculated at each time frame using the signed tetrahedron method. Then, the relative contribution of the RV wall motion along the three different directions to global RV ejection fraction was calculated either as the ratio of the given direction’s ejection fraction to global ejection fraction and as the frame-by-frame RV volume change (∆V/∆t) along the three motion directions. The ReVISION (Right VentrIcular Separate wall motIon quantificatiON) method may contribute to a better understanding of the pathophysiology of RV mechanical adaptations to different loading conditions and diseases

    Real-time three-dimensional transthoracic echocardiography in daily practice: initial experience

    Get PDF
    <p>Abstract</p> <p>Aim of the work</p> <p>To evaluate the feasibility and possible additional value of transthoracic real-time three-dimensional echocardiography (RT3D-TTE) for the assessment of cardiac structures as compared to 2D-TTE.</p> <p>Methods</p> <p>320 patients (mean age 45 ± 8.4 years, 75% males) underwent 2D-TTE and RT3D-TTE using 3DQ-Q lab software for offline analysis. Volume quantification and functional assessment was performed in 90 patients for left ventricle and in 20 patients for right ventricle. Assessment of native (112 patients) and prosthetic (30 patients) valves morphology and functions was performed. RT3D-TTE was performed for evaluation of septal defects in 30 patients and intracardiac masses in 52 patients.</p> <p>Results</p> <p>RT3D-TTE assessment of left ventricle was feasible and reproducible in 86% of patients while for right ventricle, it was (55%). RT3D-TTE could define the surface anatomy of mitral valve optimally (100%), while for aortic and tricuspid was (88% and 81% respectively). Valve area could be planimetered in 100% for the mitral and in 80% for the aortic. RT3D-TTE provided a comprehensive anatomical and functional evaluation of prosthetic valves. RT3D-TTE enface visualization of septal defects allowed optimal assessment of shape, size, area and number of defects and evaluated the outcome post device closure. RT3D-TTE allowed looking inside the intracardiac masses through multiple sectioning, valuable anatomical delineation and volume calculation.</p> <p>Conclusion</p> <p>Our initial experience showed that the use of RT3D-TTE in the assessment of cardiac patients is feasible and allowed detailed anatomical and functional assessment of many cardiac disorders.</p

    Novel Echocardiographic Biomarkers in the Management of Atrial Fibrillation

    Get PDF
    Purpose of Review: Atrial fibrillation (AF) is the most common arrhythmia in adults. The number of patients with AF is anticipated to increase annually, mainly due to the aging population alongside improved arrhythmia detection. AF is associated with a significantly elevated risk of hospitalization, stroke, thromboembolism, heart failure, and all-cause mortality. Echocardiography is one of the key components of routine assessment and management of AF. Therefore, the aim of this review is to briefly summarize current knowledge on “novel” echocardiographic parameters that may be of value in the management of AF patients. Recent Findings: Novel echocardiographic biomarkers and their clinical application related to the management of AF have been taken into consideration. Both standard parameters such as atrial size and volume but also novels like atrial strain and tissue Doppler techniques have been analyzed. Summary: A number of novel echocardiographic parameters have been proven to enable early detection of left atrial dysfunction along with increased diagnosis accuracy. This concerns particularly experienced echocardiographers. Hence, these techniques might improve the prediction of stroke and thromboembolic events among AF patients and need to be further developed and disseminated. Nonetheless, even the standard imaging parameters could be of significant value and should not be discontinued in everyday clinical practice. © 2019, The Author(s)
    • 

    corecore