16,540 research outputs found

    Optimal scan strategies for future CMB satellite experiments

    Get PDF
    The B-mode polarisation power spectrum in the Cosmic Microwave Background (CMB) is about four orders of magnitude fainter than the CMB temperature power spectrum. Any instrumental imperfections that couple temperature fluctuations to B-mode polarisation must therefore be carefully controlled and/or removed. We investigate the role that a scan strategy can have in mitigating certain common systematics by averaging systematic errors down with many crossing angles. We present approximate analytic forms for the error on the recovered B-mode power spectrum that would result from differential gain, differential pointing and differential ellipticity for the case where two detector pairs are used in a polarisation experiment. We use these analytic predictions to search the parameter space of common satellite scan strategies in order to identify those features of a scan strategy that have most impact in mitigating systematic effects. As an example we go on to identify a scan strategy suitable for the CMB satellite proposed for the ESA M5 call. considering the practical considerations of fuel requirement, data rate and the relative orientation of the telescope to the earth. Having chosen a scan strategy we then go on to investigate the suitability of the scan strategy

    Towards a new theory of practice for community health psychology

    Get PDF
    The article sets out the value of theorizing collective action from a social science perspective that engages with the messy actuality of practice. It argues that community health psychology relies on an abstract version of Paulo Freire’s earlier writing, the Pedagogy of the Oppressed, which provides scholar-activists with a ‘map’ approach to collective action. The article revisits Freire’s later work, the Pedagogy of Hope, and argues for the importance of developing a ‘journey’ approach to collective action. Theories of practice are discussed for their value in theorizing such journeys, and in bringing maps (intentions) and journeys (actuality) closer together

    Politics and the resilience of ecosystem services

    Get PDF
    © Cambridge University Press 2015Decisions around which ecosystem services are the focus for resilience-building initiatives, and ensuring that these choices do not lead to undesirable lock-in effects that compromise the possibility for future adaptation and change, are far from ..

    The key role of nitric oxide in hypoxia: hypoxic vasodilation and energy supply-demand matching

    No full text
    Significance: a mismatch between energy supply and demand induces tissue hypoxia with the potential to cause cell death and organ failure. Whenever arterial oxygen concentration is reduced, increases in blood flow - 'hypoxic vasodilation' - occur in an attempt to restore oxygen supply. Nitric oxide is a major signalling and effector molecule mediating the body's response to hypoxia, given its unique characteristics of vasodilation (improving blood flow and oxygen supply) and modulation of energetic metabolism (reducing oxygen consumption and promoting utilization of alternative pathways). Recent advances: this review covers the role of oxygen in metabolism and responses to hypoxia, the hemodynamic and metabolic effects of nitric oxide, and mechanisms underlying the involvement of nitric oxide in hypoxic vasodilation. Recent insights into nitric oxide metabolism will be discussed, including the role for dietary intake of nitrate, endogenous nitrite reductases, and release of nitric oxide from storage pools. The processes through which nitric oxide levels are elevated during hypoxia are presented, namely (i) increased synthesis from nitric oxide synthases, increased reduction of nitrite to nitric oxide by heme- or pterin-based enzymes and increased release from nitric oxide stores, and (ii) reduced deactivation by mitochondrial cytochrome c oxidase. Critical issues: several reviews covered modulation of energetic metabolism by nitric oxide, while here we highlight the crucial role NO plays in achieving cardiocirculatory homeostasis during acute hypoxia through both vasodilation and metabolic suppression Future directions: we identify a key position for nitric oxide in the body's adaptation to an acute energy supply-demand mismatc

    Inhalation characteristics of asthma patients, COPD patients and healthy volunteers with the Spiromax® and Turbuhaler® devices: a randomised, cross-over study.

    Get PDF
    BACKGROUND: Spiromax® is a novel dry-powder inhaler containing formulations of budesonide plus formoterol (BF). The device is intended to provide dose equivalence with enhanced user-friendliness compared to BF Turbuhaler® in asthma and chronic obstructive pulmonary disease (COPD). The present study was performed to compare inhalation parameters with empty versions of the two devices, and to investigate the effects of enhanced training designed to encourage faster inhalation. METHODS: This randomised, open-label, cross-over study included children with asthma (n = 23), adolescents with asthma (n = 27), adults with asthma (n = 50), adults with COPD (n = 50) and healthy adult volunteers (n = 50). Inhalation manoeuvres were recorded with each device after training with the patient information leaflet (PIL) and after enhanced training using an In-Check Dial device. RESULTS: After PIL training, peak inspiratory flow (PIF), maximum change in pressure (∆P) and the inhalation volume (IV) were significantly higher with Spiromax than with the Turbuhaler device (p values were at least <0.05 in all patient groups). After enhanced training, numerically or significantly higher values for PIF, ∆P, IV and acceleration remained with Spiromax versus Turbuhaler, except for ∆P in COPD patients. After PIL training, one adult asthma patient and one COPD patient inhaled <30 L/min through the Spiromax compared to one adult asthma patient and five COPD patients with the Turbuhaler. All patients achieved PIF values of at least 30 L/min after enhanced training. CONCLUSIONS: The two inhalers have similar resistance so inhalation flows and pressure changes would be expected to be similar. The higher flow-related values noted for Spiromax versus Turbuhaler after PIL training suggest that Spiromax might have human factor advantages in real-world use. After enhanced training, the flow-related differences between devices persisted; increased flow rates were achieved with both devices, and all patients achieved the minimal flow required for adequate drug delivery. Enhanced training could be useful, especially in COPD patients

    Options for early breast cancer follow-up in primary and secondary care : a systematic review

    Get PDF
    Background Both incidence of breast cancer and survival have increased in recent years and there is a need to review follow up strategies. This study aims to assess the evidence for benefits of follow-up in different settings for women who have had treatment for early breast cancer. Method A systematic review to identify key criteria for follow up and then address research questions. Key criteria were: 1) Risk of second breast cancer over time - incidence compared to general population. 2) Incidence and method of detection of local recurrence and second ipsi and contra-lateral breast cancer. 3) Level 1–4 evidence of the benefits of hospital or alternative setting follow-up for survival and well-being. Data sources to identify criteria were MEDLINE, EMBASE, AMED, CINAHL, PSYCHINFO, ZETOC, Health Management Information Consortium, Science Direct. For the systematic review to address research questions searches were performed using MEDLINE (2011). Studies included were population studies using cancer registry data for incidence of new cancers, cohort studies with long term follow up for recurrence and detection of new primaries and RCTs not restricted to special populations for trials of alternative follow up and lifestyle interventions. Results Women who have had breast cancer have an increased risk of a second primary breast cancer for at least 20 years compared to the general population. Mammographically detected local recurrences or those detected by women themselves gave better survival than those detected by clinical examination. Follow up in alternative settings to the specialist clinic is acceptable to women but trials are underpowered for survival. Conclusions Long term support, surveillance mammography and fast access to medical treatment at point of need may be better than hospital based surveillance limited to five years but further large, randomised controlled trials are needed

    The Shear TEsting Programme 1: Weak lensing analysis of simulated ground-based observations

    Get PDF
    The Shear TEsting Programme, STEP, is a collaborative project to improve the accuracy and reliability of all weak lensing measurements in preparation for the next generation of wide-field surveys. In this first STEP paper we present the results of a blind analysis of simulated ground-based observations of relatively simple galaxy morphologies. The most successful methods are shown to achieve percent level accuracy. From the cosmic shear pipelines that have been used to constrain cosmology, we find weak lensing shear measured to an accuracy that is within the statistical errors of current weak lensing analyses, with shear measurements accurate to better than 7%. The dominant source of measurement error is shown to arise from calibration uncertainties where the measured shear is over or under-estimated by a constant multiplicative factor. This is of concern as calibration errors cannot be detected through standard diagnostic tests. The measured calibration errors appear to result from stellar contamination, false object detection, the shear measurement method itself, selection bias and/or the use of biased weights. Additive systematics (false detections of shear) resulting from residual point-spread function anisotropy are, in most cases, reduced to below an equivalent shear of 0.001, an order of magnitude below cosmic shear distortions on the scales probed by current surveys. Our results provide a snapshot view of the accuracy of current ground-based weak lensing methods and a benchmark upon which we can improve. To this end we provide descriptions of each method tested and include details of the eight different implementations of the commonly used Kaiser, Squires and Broadhurst (1995) method (KSB+) to aid the improvement of future KSB+ analyses
    corecore