108 research outputs found
Optical fibers with interferometric path length stability by controlled heating for transmission of optical signals and as components in frequency standards
We present a simple method to stabilize the optical path length of an optical
fiber to an accuracy of about 1/100 of the laser wavelength. We study the
dynamic response of the path length to modulation of an electrically conductive
heater layer of the fiber. The path length is measured against the laser
wavelength by use of the Pound-Drever-Hall method; negative feedback is applied
via the heater. We apply the method in the context of a cryogenic resonator
frequency standard.Comment: Expanded introduction and outlook. 9 pages, 5 figure
A compact and robust diode laser system for atom interferometry on a sounding rocket
We present a diode laser system optimized for laser cooling and atom
interferometry with ultra-cold rubidium atoms aboard sounding rockets as an
important milestone towards space-borne quantum sensors. Design, assembly and
qualification of the system, combing micro-integrated distributed feedback
(DFB) diode laser modules and free space optical bench technology is presented
in the context of the MAIUS (Matter-wave Interferometry in Microgravity)
mission.
This laser system, with a volume of 21 liters and total mass of 27 kg, passed
all qualification tests for operation on sounding rockets and is currently used
in the integrated MAIUS flight system producing Bose-Einstein condensates and
performing atom interferometry based on Bragg diffraction. The MAIUS payload is
being prepared for launch in fall 2016.
We further report on a reference laser system, comprising a rubidium
stabilized DFB laser, which was operated successfully on the TEXUS 51 mission
in April 2015. The system demonstrated a high level of technological maturity
by remaining frequency stabilized throughout the mission including the rocket's
boost phase
Note: Silicon Carbide Telescope Dimensional Stability for Space-based Gravitational Wave Detectors
Space-based gravitational wave detectors are conceived to detect gravitational waves in the low frequency range by measuring the distance between proof masses in spacecraft separated by millions of kilometers. One of the key elements is the telescope which has to have a dimensional stability better than 1 pm Hz(exp 1/2) at 3 mHz. In addition, the telescope structure must be light, strong, and stiff. For this reason a potential telescope structure consisting of a silicon carbide quadpod has been designed, constructed, and tested. We present dimensional stability results meeting the requirements at room temperature. Results at 60 C are also shown although the requirements are not met due to temperature fluctuations in the setup
Silicon Carbide Telescope Investigations for the LISA Mission
Space-based gravitational wave (GW) detectors are conceived to detect GWs in the low frequency range (mili-Hertz) by measuring the distance between free-falling proof masses in spacecraft (SC) separated by 5 Gm. The reference in the last decade has been the joint ESA-NASA mission LISA. One of the key elements of LISA is the telescope since it simultaneously gathers the light coming from the far SC (approximately or equal to 100 pW) and expands, collimates and sends the outgoing beam (2 W) to the far SC. Demanding requirements have been imposed on the telescope structure: the dimensional stability of the telescope must be approximately or equal to 1pm Hz(exp1/2) at 3 mHz and the distance between the primary and the secondary mirrors must change by less than 2.5 micrometer over the mission lifetime to prevent defocussing. In addition the telescope structure must be light, strong and stiff. For this reason a potential on-axis telescope structure for LISA consisting of a silicon carbide (SiC) quadpod structure has been designed, constructed and tested. The coefficient of thermal expansion (CTE) in the LISA expected temperature range has been measured with a 1% accuracy which allows us to predict the shrinkage/expansion of the telescope due to temperature changes, and pico-meter dimensional stability has been measured at room temperature and at the expected operating temperature for the LISA telescope (around -6[deg]C). This work is supported by NASA Grants NNX10AJ38G and NX11AO26G
LTP interferometer - noise sources and performance
The LISA Technology Package (LTP) uses laser interferometry to measure the changes in relative displacement between two inertial test masses. The goals of the mission require a displacement measuring precision of 10 pm Hz-1/2 at frequencies in the 3–30 mHz band. We report on progress with a prototype LTP interferometer optical bench in which fused silica mirrors and beamsplitters are fixed to a ZERODUR® substrate using hydroxide catalysis bonding to form a rigid interferometer. The couplings to displacement noise of this interferometer of two expected noise sources—laser frequency noise and ambient temperature fluctuations—have been investigated, and an additional, unexpected, noise source has been identified. The additional noise is due to small amounts of signal at the heterodyne frequency arriving at the photodiode preamplifiers with a phase that quasistatically changes with respect to the optical signal. The phase shift is caused by differential changes in the external optical paths the beams travel before they reach the rigid interferometer. Two different external path length stabilization systems have been demonstrated and these allowed the performance of the overall system to meet the LTP displacement noise requirement
Modern Michelson-Morley experiment using cryogenic optical resonators
We report on a new test of Lorentz invariance performed by comparing the
resonance frequencies of two orthogonal cryogenic optical resonators subject to
Earth's rotation over 1 year. For a possible anisotropy of the speed of light
c, we obtain 2.6 +/- 1.7 parts in 10^15. Within the Robertson-Mansouri-Sexl
test theory, this implies an isotropy violation parameter beta - delta - 1/2 of
-2.2 +/- 1.5 parts in 10^9, about three times lower than the best previous
result. Within the general extension of the standard model of particle physics,
we extract limits on 7 parameters at accuracies down to a part in 10^15,
improving the best previous result by about two orders of magnitude
Tests of Relativity using a cryogenic optical resonator.
A 190-day comparison of the optical frequencies defined by an optical cavity and a molecular electronic transition is analyzed for the velocity independence of the speed of light (Kennedy-Thorndike test) and the universality of the gravitational redshift. The modulation of the laboratory velocity and the gravitational potential were provided by Earth's orbital motion around the Sun. We find a velocity-dependence coefficient of ͑1.9 6 2.1͒ 3 10 25 , 3 times lower compared to the best previous test. Alternatively, the data confirm the gravitational redshift for an electronic transition at the 4% level. Prospects for significant improvements of the tests are discussed. DOI: 10.1103/PhysRevLett.88.010401 PACS numbers: 03.30. +p, 07.60. -j Special relativity (SR) is one of the fundamental theories of nature. The prominent role of the theory as a basis of our physical view of nature has motivated experimenters to test its foundations and predictions with ever increasing accuracy. Added motivation for tests is provided by the theoretical efforts to unify the forces of nature. For example, approaches towards a quantum theory of gravity have been put forward that lead to modified Maxwell equations which are not necessarily Lorentz covariant The relationship between gravity and the other forces of nature can also be probed by measuring the gravitational frequency shift ("redshift") of clocks based on these forces. The principle of local position invariance (LPI) Thanks to worldwide developments in frequency metrology and ultrastable oscillators, especially in the optical domain, the opportunity has arisen to improve the knowledge of SR and LPI by several orders of magnitude. Here we report on a first step in this direction, based on a laboratory experiment. We remark that space experiments have also been proposed Test of special relativity.-According to the kinematical analysis of Robertson [6] as well as Mansouri and Sexl A violation of the constancy of the speed of light implies a dependence of c͑v͒ on the magnitude y of the laboratory velocity relative to a hypothetical preferred frame of reference S, and on the angle u between the propagation direction of the light and the direction of v. The natural candidate for S is the cosmic microwave background. From isotropy in the preferred frame S, it follows that c͑v͒ is an even function of y. According to common test theories where c 0 is the constant speed of light in the preferred frame S. A and B vanish if SR is valid. In the test theory framework of The laboratory velocity y͑t͒ has contributions from the motion of the Sun through S with a constant velocity y s 377 km͞s, Earth's orbital motion around the Sun (orbital velocity y e 30 km͞s), and Earth's daily rotation (velocity y d ഠ 330 m͞s at the latitude of Konstanz), y͑t͒ y s 1 y e sin͓V y ͑t 2 t 0 ͔͒ cosF E Here F A ഠ 8 ± is the angle between the equatorial plane and the velocity of the sun. F E 6 ± is the declination between the plane of Earth's orbit and the velocity of the Sun [9], 2p͞V y 1 yr, 2p͞V d 1 sidereal day. t 0 and t d are determined by the phase and start date of the measurement, respectively. 010401-1 0031-9007͞02͞ 88(1)͞010401(4)$15.0
The Space Optical Clocks Project: Development of high-performance transportable and breadboard optical clocks and advanced subsystems
The use of ultra-precise optical clocks in space ("master clocks") will allow
for a range of new applications in the fields of fundamental physics (tests of
Einstein's theory of General Relativity, time and frequency metrology by means
of the comparison of distant terrestrial clocks), geophysics (mapping of the
gravitational potential of Earth), and astronomy (providing local oscillators
for radio ranging and interferometry in space). Within the ELIPS-3 program of
ESA, the "Space Optical Clocks" (SOC) project aims to install and to operate an
optical lattice clock on the ISS towards the end of this decade, as a natural
follow-on to the ACES mission, improving its performance by at least one order
of magnitude. The payload is planned to include an optical lattice clock, as
well as a frequency comb, a microwave link, and an optical link for comparisons
of the ISS clock with ground clocks located in several countries and
continents. Undertaking a necessary step towards optical clocks in space, the
EU-FP7-SPACE-2010-1 project no. 263500 (SOC2) (2011-2015) aims at two
"engineering confidence", accurate transportable lattice optical clock
demonstrators having relative frequency instability below 1\times10^-15 at 1 s
integration time and relative inaccuracy below 5\times10^-17. This goal
performance is about 2 and 1 orders better in instability and inaccuracy,
respectively, than today's best transportable clocks. The devices will be based
on trapped neutral ytterbium and strontium atoms. One device will be a
breadboard. The two systems will be validated in laboratory environments and
their performance will be established by comparison with laboratory optical
clocks and primary frequency standards. In this paper we present the project
and the results achieved during the first year.Comment: Contribution to European Frequency and Time Forum 2012, Gothenburg,
Swede
Limits on cosmological variation of quark masses and strong interaction
We discuss limits on variation of . The results are
obtained by studying -interaction during Big Bang, Oklo natural
nuclear reactor data and limits on variation of the proton -factor from
quasar absorpion spectra.Comment: 5 pages, RevTe
- …