36 research outputs found

    Avaliação da reprodutibilidade dos núcleos metálicos fundidos em função da quantidade e posicionamento dos padrões de resina no anel de fundição

    Get PDF
    The aim of this study was the evaluation about the influence of the quantity and the localization of resin patterns to cast metallic posts in its diameter and length reproduction. Seventy-two patterns for posts were fabricated by using prefabricated FKG plastic posts and divided for casting in 3 groups: G1-small ring/4 patterns, G2- medium ring/6 patterns, G3- big ring/8 patterns. Half of the patterns of each group were placed on the right side of the ring midline and the other half, on the left side, in order to guide the ring inside of the centrifuge. Using the comparative microscope, measures of diameter and length in different places were obtained before and after casting. The results were submitted to statistic analysis (ANOVA two way and Tukey's test), to make possible these observations: 1°) the position of patterns didn't influenced the measured dimensions. 2°) the same happened with the quantity of patterns inside the ring. 3°) only the pins of group G3 have presented statistically significant diameter differences. In conclusion, 1°) the position of patterns inside the ring and its quantity did not result in significant changes in pins length and diameter. 2°) Although there were no significant length alterations, significant ones were observed in the diameters 3, 6, and 9mm of Group G3.O objetivo deste trabalho foi avaliar a influência do número e localização de padrões de resina para fundição de núcleos metálicos fundidos (NMF), na reprodução do diâmetro e comprimento dos pinos. Foram confeccionados 72 padrões de resina utilizando pinos plásticos pré-fabricados e divididos para fundição em 3 grupos: G1- anel pequeno/4padrões, G2- anel médio/6 padrões e G3-anel grande/8 padrões. Metade deles foi posicionada à direita da linha média do anel e metade à esquerda, servindo de orientação para posicionar o anel na centrífuga. Através do microscópio comparador foram obtidas medidas antes e depois da fundição, tanto do comprimento quanto do diâmetro em diferentes locais. Os resultados foram submetidos à análise estatística (ANOVA a dois critérios e Tukey), possibilitando as seguintes observações: 1°) a posição dos padrões não exerceu influência nas dimensões mensuradas. 2°) o mesmo ocorreu com a quantidade de padrões dentro do anel. 3°) apenas em relação ao diâmetro (3 e 6mm) dos pinos do grupo G3, houve diferença estatisticamente significante. Conclui-se que: 1°) a posição do padrão dentro do anel e o número de padrões não resultou em alteração significativa do comprimento e diâmetro dos pinos. 2°) A variação de diâmetro (3, 6, e 9mm) foi significante apenas para os pinos do grupo G3

    Uso de ligas metálicas básicas em próteses sobre implantes: análise da adaptação marginal

    Get PDF
    The original protocol for implant prosthesis recommends the use of a gold framework for acrylic and ceramic prosthesis. However, due to its high cost, the use of alternative alloys is desired. This study compares the marginal accuracy of pre-made cylinders versus plastic cylinders cast with two different base metal casting alloys. Five samples each of (1) plastic cylinder cast in cobalt-chromium alloy, (2) plastic cylinder cast in nickel-chromium alloy, and (3) silver-palladium pre-made cylinder (control) were examined for marginal accuracy according to: (A) vertical gap; (B) horizontal gap and (C) horizontal gap depth at the abutment/cylinder interface. Data were submitted to statistical analysis (ANOVA and Student-Newman Keuls, pO protocolo para prótese sobre implantes recomenda o uso de uma infra-estrutura em ouro para próteses metalo-plásticas e metalo-cerâmicas. No entanto, devido ao seu alto custo, o uso de ligas alternativas é desejado. OBJETIVO: Este estudo compara a adaptação marginal de cilindros protéticos pré-fabricados e cilindros protéticos plásticos fundidos com dois tipos de ligas metálicas básicas. MATERIAL E MÉTODOS: 05 amostras de (1) cilindros plásticos fundidos em liga de cobalto cromo; (2) cilindros plásticos fundidos em liga de níquel cromo e (3) cilindros pré-fabricados com cinta metálica em paládio, foram examinados na interface intermediário/cilindro protético na análise de desajuste marginal, considerando-se (A) desajuste vertical, (B) desajuste horizontal e (C) profundidade de fenda. RESULTADOS: os valores médios para o desajuste vertical, horizontal e profundidade foram, respectivamente, 4,13µm, 14,5µm e 6,93µm para o cilindro pré-fabricado em paládio, 23,18µm, 33,2µm e 88µm para os cilindros plásticos fundidos em Níquel cromo e 25,6µm, 51,8µm e 114,54 µm para os cilindros fundidos em cobalto-cromo. CONCLUSÃO: não foram encontradas diferenças estatísticas entre os grupos fundidos (grupo 1 e 2), mas uma adaptação marginal significantemente superior foi observada com os cilindros pré-fabricados quando comparado aos cilindros plásticos fundidos com níquel-cromo e cobalto-cromo para todas as análises

    Resistência à fratura e padrão de falha de dentes submetidos ao clareamento interno com peróxido de carbamida a 37%, com aplicação de diferentes procedimentos restauradores

    Get PDF
    OBJECTIVE: This study investigated the compressive fracture strength and failure pattern in premolars submitted to endodontic treatment and internal bleaching with 37% carbamide peroxide for 21 days, with application of different restorative procedures. MATERIAL AND METHODS: Six groups were employed (n = 10): 1) non-bleached teeth and pulp chamber sealed with IRM; 2) bleached teeth and pulp chamber sealed with IRM; 3) bleached teeth and pulp chamber filled with light cured composite resin; 4) bleached teeth, root canals prepared at 10mm, filling of the root canal and pulp chamber with IRM; 5) bleached teeth, root canals prepared at 10mm, luting of prefabricated metallic post with zinc phosphate and pulp chamber sealed with composite resin; 6) bleached teeth, root canals prepared at 10mm, luting of glass fiber post with resin cement and pulp chamber sealed with composite resin. After 24-hour storage in distilled water, the specimens were submitted to compressive fracture strength testing in a universal testing machine. RESULTS: The following values were found: Group 1 - 56.23kgf; Group 2 - 48.96kgf; Group 3 - 53.99kgf; Group 4 - 45.72kgf; Group 5 - 54.22kgf; Group 6 - 60.12kgf. The analysis of variance did not reveal statistically significant difference between groups (pOBJETIVO: O objetivo do estudo foi investigar a resistência à fratura sob compressão e padrão de falha de pré-molares tratados endodonticamente e clareados internamente por 21 dias com peróxido de carbamida a 37%, aplicando-se diferentes procedimentos restauradores. MATERIAL E MÉTODOS: O objetivo deste estudo foi investigar a resistência à fratura sob compressão e padrão de falha de pré-molares unirradiculares tratados endodonticamente e clareados internamente com peróxido de carbamida a 37%. Foram constituídos 6 grupos (n = 10): 1) dentes sem clareamento e câmara pulpar vedada com IRM; 2) dentes clareados e câmara pulpar vedada com IRM; 3) dentes clareados e câmara pulpar preenchida com resina composta fotopolimerizável; 4) dentes clareados, condutos preparados com 10mm, e preenchimento do conduto e câmara pulpar com IRM; 5) dentes clareados, condutos preparados com 10mm, cimentação de pino metálico pré-fabricado com fosfato de zinco e câmara pulpar vedada com resina composta; 6) dentes clareados, condutos preparados com 10mm, cimentação de pino de fibra de vidro com cimento resinoso e câmara pulpar vedada com resina composta. Após 24 horas de armazenamento em água destilada, os espécimes foram submetidos ao teste de resistência à fratura sob compressão em máquina de ensaios universal. RESULTADOS: Os seguintes valores foram encontrados: grupo 1 - 56,23kgf; grupo 2 - 48,96kgf; grupo 3 - 53,99kgf; grupo 4 - 45,72kgf; grupo 5 - 54,22kgf; grupo 6 - 60,12kgf. A Análise de Variância não mostrou diferença estatisticamente significante entre os grupos (p < .05), sugerindo que o clareamento interno com peróxido de carbamida a 37% não enfraqueceu os tecidos dentais. O maior número de fraturas desfavoráveis foi encontrado nos grupos 2 (50%), 4 (40%), e 5 (30%). O grupo 6 exibiu o padrão de falhas mais favorável. CONCLUSÃO: Os resultados sugerem que o clareamento interno com peróxido de carbamida a 37% não causou enfraquecimento importante dos dentes. Entre os dentes clareados, aqueles com restaurações temporárias de IRM ou com pinos metálicos mostraram o padrão mais desfavorável de fratura, enquanto o padrão de fratura mais favorável ocorreu em dentes restaurados com resina composta e pinos de fibras de vidro

    Utilization of biological posts to reconstruct weakened roots

    Get PDF
    Adequate reconstruction of endodontically treated teeth with severe loss of dentine tissue is one of the challenges of Restorative Dentistry. None of the commercially available pre-fabricated intraradicular posts meets all ideal biological and mechanical properties. Recently, a technique for the reconstruction of pulpless teeth with weakened roots has been indicated – the use of dental posts obtained from natural teeth. This article presents, through a clinical case, important details for the execution of the technique

    Residual stress estimated by nanoindentation in pontics and abutments of veneered zirconia fixed dental prostheses

    Get PDF
    Glass ceramics’ fractures in zirconia fixed dental prosthesis (FDP) remains a clinical challenge since it has higher fracture rates than the gold standard, metal ceramic FDP. Nanoindentation has been shown a reliable tool to determine residual stress of ceramic systems, which can ultimately correlate to failure-proneness. Objectives: To assess residual tensile stress using nanoindentation in veneered three-unit zirconia FDPs at different surfaces of pontics and abutments. Methodology: Three composite resin replicas of the maxillary first premolar and crown-prepared abutment first molar were made to obtain three-unit FDPs. The FDPs were veneered with glass ceramic containing fluorapatite crystals and resin cemented on the replicas, embedded in epoxy resin, sectioned, and polished. Each specimen was subjected to nanoindentation in the following regions of interest: 1) Mesial premolar abutment (MPMa); 2) Distal premolar abutment (DPMa); 3) Buccal premolar abutment (BPMa); 4) Lingual premolar abutment (LPMa); 5) Mesial premolar pontic (MPMp); 6) Distal premolar pontic (DPMp); 7) Buccal premolar pontic (BPMp); 8) Lingual premolar pontic (LPMp); 9) Mesial molar abutment (MMa); 10) Distal molar abutment (DMa); 11) Buccal molar abutment (BMa); and 12) Lingual molar abutment (LMa). Data were assessed using Linear Mixed Model and Least Significant Difference (95%) tests. Results: Pontics had significantly higher hardness values than premolar (p=0.001) and molar (p=0.007) abutments, suggesting lower residual stress levels. Marginal ridges yielded higher hardness values for connectors (DPMa, MMa, MPMp and DPMp) than for outer proximal surfaces of abutments (MPMa and DMa). The mesial marginal ridge of the premolar abutment (MPMa) had the lowest hardness values, suggesting higher residual stress concentration. Conclusions: Residual stress in three-unit FDPs was lower in pontics than in abutments. The outer proximal surfaces of the abutments had the highest residual stress concentration

    Sealing Capability and SEM Observation of the Implant-Abutment Interface

    Get PDF
    To evaluate the sealing capability of external hexagon implant systems and assess the marginal fit, two groups (n = 10 each) were employed: SIN (Sistema de Implantes Nacional, Brazil) and Osseotite, (Biomet 3i, USA). Sealing capability was determined by placing 0.7 μL of 1% acid-red solution in the implant wells before the torque of their respective abutments. Specimens were then placed into 2.5 mL vials filled with 1.3 mL of distilled water with the implant-abutment interface submerged. Three samples of 100 μL water were collected at previously determinate times. The absorbance was measured with a spectrophotometer, and the data were analyzed by Two-way ANOVA (P < .05) and Tukey's test. Marginal fit was determined using SEM. Leakage was observed for both groups at all times and was significantly higher at 144 hrs. SEM analysis depicted gaps in the implant-abutment interface of both groups. Gaps in the implant-abutment interface were observed along with leakage increased at the 144 hrs evaluation period

    Evaluation of fracture resistance of endodontically treated teeth restored with prefabricated posts and composites with varying quantities of remaining coronal tooth structure

    Get PDF
    O objetivo desta pesquisa foi avaliar a influência do remanescente dentário coronal de dentes tratados endodonticamente, restaurados com pinos pré-fabricados e duas resinas como núcleos de preenchimento, uma de presa dual (Enforce Core) e outra fotopolimerizável (Z-250). Foram utilizados 40 caninos superiores humanos extraídos, divididos em quatro grupos de 10 espécimes: Grupo l - com remanescente dentário coronal de 3mm e restaurados com Enforce Core; Grupo ll - com remanescente dentário coronal de 3mm e restaurado com Z-250; Grupo III - sem remanescente dentário coronal e restaurado com Enforce Core; Grupo IV - sem remanescente dentário coronal e restaurado com Z-250. Após restaurados, os dentes foram levados a uma Máquina de Ensaio Universal e submetidos a uma força de compressão à 45º até que ocorresse fratura da restauração. A análise dos resultados (ANOVA, p>;0,05) mostrou não haver diferença estatisticamente significativa entre os dentes com e sem remanescente dentário coronal. Com relação ao material utilizado para o preenchimento coronário, constatou-se diferença significativa, sendo que os valores mais elevados de resistência à fratura foram encontrados no grupo restaurado com a resina fotopolimerizável.OBJECTIVES: The aim of this study was to evaluate the influence of remaining coronal tooth structure on endodontically treated teeth restored with prefabricated posts and two different composites for core build-up: dual-cured resin (Enforce Core) and light-cured resin (Z-250). METHODS: Fourty freshly extracted canines were endodontically treated and divided into four groups: Group I - teeth with 3mm remaining coronal structure, restored with Enforce Core; Group II - teeth with 3mm remaining coronal structure, restored with Z-250; Group III - teeth with no remaining coronal structure, restored with Enforce; Group IV - teeth with no remaining coronal structure, restored with Z-250. After restoration, the teeth were embedded in acrylic resin and the fracture resistance was measured on a universal testing machine at 45 degrees to the long axis of the tooth until failure. RESULTS: Data were analyzed by two-way analysis of variance, which showed significant differences between groups (p=0.00). The Tukey test did not show significant differences between specimens with and without remaining coronal structure. Conversely, significant difference was observed between groups with different core build-up. The highest values of fracture resistance were found in the group restored with light-cured resin. SIGNIFICANCE: The remaining coronal tooth structure did not influence the resistance of endodontically treated teeth; however, the change of core build-up was able to modify this resistence

    In vitro wear resistance of three types of polymethyl methacrylate denture teeth

    Get PDF
    The wear resistance of denture teeth is important to the longevity of removable prostheses of edentulous patients. The ability of denture teeth to maintain a stable occlusal relationship over time may be influenced by this property. The purpose of this in vitro study was to evaluate the wear resistance of polymethyl methacrylate (PMMA) denture teeth based on their chemical composition when opposed by a ceramic antagonist. The maxillary canines (n=10) of 3 PMMA denture teeth (Trubyte Biotone, cross-linked PMMA; Trilux, highly cross-linked IPN (interpenetrating polymer network)-PMMA; and Vivodent, highly cross-linked PMMA) were secured in an in vitro 2-body wear-testing apparatus that produced sliding contact of the specimens (4.5 cycles/s, sliding distance of 20 mm, under 37°C running water) against glazed or airborne particle abraded ceramic. Wear resistance was measured as height loss (mm) under 300 g (sliding force) after 100,000 cycles, using a digital measuring microscope. Mean values were analyzed by 2-way ANOVA and Tukey's test (a=0.05). The wear of Trubyte Biotone (0.93 ± 0.14 mm) was significantly higher than that of both other types of teeth tested against abraded ceramic (p<0.05). The Vivodent tooth (0.64 ± 0.17 mm) exhibited the best wear resistance among the denture teeth tested against airborne particle abraded ceramic. There were no statistically significant differences (p>0.05) in wear among the 3 denture teeth evaluated against glazed ceramic. Trilux and Vivodent teeth tested against either glazed or airborne particle abraded ceramic did not differ significantly from each other (p<0.05). All teeth showed significantly more wear against airborne particle abraded ceramic than against glazed ceramic (p<0.05). In conclusion, the three types of PMMA denture teeth presented significantly different wear resistance against the abraded ceramic. The high-strength PMMA denture teeth were more wear-resistant than the conventional PMMA denture tooth.Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq

    Internal fit of two all-ceramic systems and metal-ceramic crowns

    Get PDF
    OBJECTIVES: The aim of this study was to investigate the internal fit (IF) of glass-infiltrated alumina (ICA - In-Ceram Alumina), yttria-stabilized tetragonal zirconia polycrystals (Y-TZP - IPS e.max ZirCAD), and metal-ceramic (MC - Ni-Cr alloy) crowns. MATERIAL AND METHODS: Sixty standardized resin-tooth replicas of a maxillary first molar were produced for crown placement and divided into 3 groups (n=20 each) according to the core material used (metal, ICA or Y-TZP). The IF of the crowns was measured using the replica technique, which employs a light body polyvinyl siloxane impression material to simulate the cement layer thickness. The data were analyzed according to the surfaces obtained for the occlusal space (OS), axial space (AS) and total mean (TM) using two-way ANOVA with Tukey s multiple comparison test (p<0.05). RESULTS: No differences among the different areas were detected in the MC group. For the Y-TZP and ICA groups, AS was statistically lower than both OS and TM. No differences in AS were observed among the groups. However, OS and TM showed significantly higher values for ICA and Y-TZP groups than MC group. Comparisons of ICA and Y-TZP revealed that OS was significantly lower for Y-TZP group, whereas no differences were observed for TM. CONCLUSIONS: The total mean achieved by all groups was within the range of clinical acceptability. However, the metal-ceramic group demonstrated significantly lower values than the all-ceramic groups, especially in OS
    corecore