41 research outputs found

    Risk factors for hospital admission with RSV bronchiolitis in England: a population-based birth cohort study.

    Get PDF
    OBJECTIVE: To examine the timing and duration of RSV bronchiolitis hospital admission among term and preterm infants in England and to identify risk factors for bronchiolitis admission. DESIGN: A population-based birth cohort with follow-up to age 1 year, using the Hospital Episode Statistics database. SETTING: 71 hospitals across England. PARTICIPANTS: We identified 296618 individual birth records from 2007/08 and linked to subsequent hospital admission records during the first year of life. RESULTS: In our cohort there were 7189 hospital admissions with a diagnosis of bronchiolitis, 24.2 admissions per 1000 infants under 1 year (95%CI 23.7-24.8), of which 15% (1050/7189) were born preterm (47.3 bronchiolitis admissions per 1000 preterm infants (95% CI 44.4-50.2)). The peak age group for bronchiolitis admissions was infants aged 1 month and the median was age 120 days (IQR = 61-209 days). The median length of stay was 1 day (IQR = 0-3). The relative risk (RR) of a bronchiolitis admission was higher among infants with known risk factors for severe RSV infection, including those born preterm (RR = 1.9, 95% CI 1.8-2.0) compared with infants born at term. Other conditions also significantly increased risk of bronchiolitis admission, including Down's syndrome (RR = 2.5, 95% CI 1.7-3.7) and cerebral palsy (RR = 2.4, 95% CI 1.5-4.0). CONCLUSIONS: Most (85%) of the infants who are admitted to hospital with bronchiolitis in England are born at term, with no known predisposing risk factors for severe RSV infection, although risk of admission is higher in known risk groups. The early age of bronchiolitis admissions has important implications for the potential impact and timing of future active and passive immunisations. More research is needed to explain why babies born with Down's syndrome and cerebral palsy are also at higher risk of hospital admission with RSV bronchiolitis

    Photonic gas sensors exploiting directly the optical properties of hybrid carbon nanotube localized surface plasmon structures

    Get PDF
    We investigate the modification of the optical properties of carbon nanotubes (CNTs) resulting from a chemical reaction triggered by the presence of a specific compound (gaseous carbon dioxide (CO2)) and show this mechanism has important consequences for chemical sensing. CNTs have attracted significant research interest because they can be functionalized for a particular chemical, yielding a specific physical response which suggests many potential applications in the fields of nanotechnology and sensing. So far, however, utilizing their optical properties for this purpose has proven to be challenging. We demonstrate the use of localized surface plasmons generated on a nanostructured thin film, resembling a large array of nano-wires, to detect changes in the optical properties of the CNTs. Chemical selectivity is demonstrated using CO2 in gaseous form at room temperature. The demonstrated methodology results additionally in a new, electrically passive, optical sensing configuration that opens up the possibilities of using CNTs as sensors in hazardous/explosive environments

    Cell-surface sensors for real-time probing of cellular environments

    Get PDF
    Author Manuscript 2012 August 1.The ability to explore cell signalling and cell-to-cell communication is essential for understanding cell biology and developing effective therapeutics. However, it is not yet possible to monitor the interaction of cells with their environments in real time. Here, we show that a fluorescent sensor attached to a cell membrane can detect signalling molecules in the cellular environment. The sensor is an aptamer (a short length of single-stranded DNA) that binds to platelet-derived growth factor (PDGF) and contains a pair of fluorescent dyes. When bound to PDGF, the aptamer changes conformation and the dyes come closer to each other, producing a signal. The sensor, which is covalently attached to the membranes of mesenchymal stem cells, can quantitatively detect with high spatial and temporal resolution PDGF that is added in cell culture medium or secreted by neighbouring cells. The engineered stem cells retain their ability to find their way to the bone marrow and can be monitored in vivo at the single-cell level using intravital microscopy.National Institutes of Health (U.S.) (Grant HL097172)National Institutes of Health (U.S.) (Grant HL095722)National Institutes of Health (U.S.) (Grant DE019191)National Institutes of Health (U.S.) (Grant NIAID 5RC1AI086152)Charles A. Dana FoundationAmerican Heart Association (Grant 0970178N)National Science Foundation (U.S.) (Graduate Fellowship

    Surgical treatment of neurological scoliosis using hybrid construct (lumbar transpedicular screws plus thoracic sublaminar acrylic loops)

    No full text
    In the nineties, most spinal surgeons supported the validity of segmental spine instrumentation, but this procedure has progressively been abandoned because difficult and with a high risk of neurological complications, in favor of the Cotrel-Dobousset (CD). The CD instrumentation is based on segmentation of curves, thus improving the angular correction and actuates sagittal profile. Sublaminar acrylic loops (Universal Clamp) shows the same resistance to stress as steel or titanium alloy sublaminar wires. The simple procedure and the tensioning of the strips allows re-tensioning and progressive correction. The increased contact area, improves corrective forces, thus reducing the risk of laminar fractures. The aim of this study was to verify the validity of this spinal fixation implant in the surgical treatment of a consecutive series of patients affected by neurologic scoliosis. The authors treated surgically 84 patients affected by neurologic scoliosis with an average age of 14 years (range 10–17). Universal Clamps associated with Socore TM spinal assembly, transpedicular lumbar screws and thoracic hooks at the upper end of the curve were used. The etiology of disease was cerebral palsy in 81 cases, Friedreich ataxia in two cases and Aicardi syndrome in one case. The average preoperative angular value was 73° ± 16°. It was implanted a mean of seven Clamps for each procedure (range 5–9). The average percentage of correction was 72%. Mean operative time was 240 ± 30 min with mean blood loss of 1200 ± 400 ml. No intra-operative complications occurred. Mean follow-up was 36 months. At one-year follow-up the mean loss of correction was 7° ± 2° with no re-intervention required. This is the first report on treatment of neurological scoliosis with this hybrid construct (lumbar screws, thoracic acrylic clamps, thoracic hooks at the upper end of the curve). In this group of patients the Universal Clamps technique appeared safe and effective and its mechanical performance is comparable to all-level screws construct. Furthermore, the kyphotic component can be better managed in case of thoracic lordosis. The most important aspect of this technique is a short operative time and low vascular and neurologic risks combined with a satisfying stability in the short-postoperative period. Nevertheless, it is important to value results on a long-term follow-up to analyze correction loss, pseudoarthrosis, and mechanical failure of the strips

    Evaluation of thoracic pedicle screw placement in adolescent idiopathic scoliosis

    No full text
    Pedicle screw fixation is a challenging procedure in thoracic spine, as inadvertently misplaced screws have high risk of complications. The accuracy of pedicle screws is typically defined as the screws axis being fully contained within the cortices of the pedicle. One hundred and eighty-five thoracic pedicle screws in 19 patients that were drawn from a total of 1.797 screws in 148 scoliosis patients being suspicious of medial and lateral malpositioning were investigated, retrospectively. Screw containment and the rate of misplacement were determined by postoperative axial CT sections. Medial screw malposition was measured between medial pedicle wall and medial margin of the pedicle screw. The distance between lateral margin of the pedicle screw and lateral vertebral corpus was measured in lateral malpositions. A screw that violated medially greater than 2 mm, while lateral violation greater than 6 mm was rated as an “unacceptable screw”. The malpositions were medial in 20 (10.8%) and lateral in 34 (18.3%) screws. Medially, nine screws were rated as acceptable. Of the 29 acceptable lateral misplacement, 13 showed significant risk; five to aorta, six to pleura, one to azygos vein and one to trachea. The acceptability of medial pedicle breach may change in each level with different canal width and a different amount of cord shift. In lateral acceptable malpositions, the aorta is always at a risk by concave-sided screws. This CT-based study demonstrated that T4–T9 concave segments have a smaller safe zone with respect to both cord-aorta injury in medial and lateral malpositions. In these segments, screws should be accurate and screw malposition is to be unacceptable
    corecore