628 research outputs found

    Depinning of three-dimensional drops from wettability defects

    Full text link
    Substrate defects crucially influence the onset of sliding drop motion under lateral driving. A finite force is necessary to overcome the pinning influence even of microscale heterogeneities. The depinning dynamics of three-dimensional drops is studied for hydrophilic and hydrophobic wettability defects using a long-wave evolution equation for the film thickness profile. It is found that the nature of the depinning transition explains the experimentally observed stick-slip motion.Comment: 6 pages, 9 figures, submitted to ep

    Determination of CP and CPT violation parameters in the neutral kaon system using the Bell-Steinberger relation and data from the KLOE experiment

    Get PDF
    We present an improved determination of the CP and CPT violation parameters Re(epsilon) and Im(delta) based on the unitarity condition (Bell-Steinberger relation) and on recent results from the KLOE experiment. We find Re(epsilon) = (159.6 \pm 1.3)10^-5 and Im(delta) = (0.4 \pm 2.1)10^-5, consistent with no CPT violation.Comment: Submitted to JHE

    Study of the a_0(980) meson via the radiative decay phi->eta pi^0 gamma with the KLOE detector

    Full text link
    We have studied the phi->a_0(980) gamma process with the KLOE detector at the Frascati phi-factory DAPhNE by detecting the phi->eta pi^0 gamma decays in the final states with eta->gamma gamma and eta->pi^+ pi^- pi^0. We have measured the branching ratios for both final states: Br(phi->eta pi^0 gamma)=(7.01 +/- 0.10 +/- 0.20)x10^-5 and (7.12 +/- 0.13 +/- 0.22)x10^-5 respectively. We have also extracted the a_0(980) mass and its couplings to eta pi^0, K^+ K^-, and to the phi meson from the fit of the eta pi^0 invariant mass distributions using different phenomenological models.Comment: 17 pages, 6 figures, submitted to Physics Letters B. Corrected typos in eq.

    A global fit to determine the pseudoscalar mixing angle and the gluonium content of the eta' meson

    Full text link
    We update the values of the eta-eta' mixing angle and of the eta' gluonium content by fitting our measurement R_phi = BR(phi to eta' gamma)/ BR(phi to eta gamma) together with several vector meson radiative decays to pseudoscalars (V to P gamma), pseudoscalar mesons radiative decays to vectors (P to V gamma) and the eta' to gamma gamma, pi^0 to gamma gamma widths. From the fit we extract a gluonium fraction of Z^2_G = 0.12 +- 0.04, the pseudoscalar mixing angle psi_P = (40.4 +- 0.6) degree and the phi-omega mixing angle psi_V = (3.32 +- 0.09) degree. Z^2_G and psi_P are fairly consistent with those previously published. We also evaluate the impact on the eta' gluonium content determination of future experimental improvements of the eta' branching ratios and decay width.Comment: 13 pages, 7 figures to submit to JHE

    Measurements of the Absolute Branching Ratios for the Dominant KL Decays, the KL Lifetime, and Vus with the KLOE Detector

    Full text link
    From a sample of about 10^9 Phi mesons produced at DAFNE, we have selected KL mesons tagged by observing KS->pi+pi- decays. We present results on the major KL branching ratios, including those of the semileptonic decays needed for the determination of Vus. These branching ratio measurements are fully inclusive with respect to final-state radiation. The KL lifetime has also been measured.Comment: Submitted to Phys. Lett.

    Interpreting ambiguous ‘trace’ results in Schistosoma mansoni CCA Tests: Estimating sensitivity and specificity of ambiguous results with no gold standard

    Get PDF
    Background The development of new diagnostics is an important tool in the fight against disease. Latent Class Analysis (LCA) is used to estimate the sensitivity and specificity of tests in the absence of a gold standard. The main field diagnostic for Schistosoma mansoni infection, Kato-Katz (KK), is not very sensitive at low infection intensities. A point-of-care circulating cathodic antigen (CCA) test has been shown to be more sensitive than KK. However, CCA can return an ambiguous ‘trace’ result between ‘positive’ and ‘negative’, and much debate has focused on interpretation of traces results. Methodology/Principle findings We show how LCA can be extended to include ambiguous trace results and analyse S. mansoni studies from both Côte d’Ivoire (CdI) and Uganda. We compare the diagnostic performance of KK and CCA and the observed results by each test to the estimated infection prevalence in the population. Prevalence by KK was higher in CdI (13.4%) than in Uganda (6.1%), but prevalence by CCA was similar between countries, both when trace was assumed to be negative (CCAtn: 11.7% in CdI and 9.7% in Uganda) and positive (CCAtp: 20.1% in CdI and 22.5% in Uganda). The estimated sensitivity of CCA was more consistent between countries than the estimated sensitivity of KK, and estimated infection prevalence did not significantly differ between CdI (20.5%) and Uganda (19.1%). The prevalence by CCA with trace as positive did not differ significantly from estimates of infection prevalence in either country, whereas both KK and CCA with trace as negative significantly underestimated infection prevalence in both countries. Conclusions Incorporation of ambiguous results into an LCA enables the effect of different treatment thresholds to be directly assessed and is applicable in many fields. Our results showed that CCA with trace as positive most accurately estimated infection prevalence
    • …
    corecore