907 research outputs found

    Optimization of glycolipid synthesis in hydrophilic deep eutectic solvents

    Get PDF
    Glycolipids are considered an alternative to petrochemically based surfactants because they are non-toxic, biodegradable, and less harmful to the environment while having comparable surface-active properties. They can be produced chemically or enzymatically in organic solvents or in deep eutectic solvents (DES) from renewable resources. DES are non-flammable, non-volatile, biodegradable, and almost non-toxic. Unlike organic solvents, sugars are easily soluble in hydrophilic DES. However, DES are highly viscous systems and restricted mass transfer is likely to be a major limiting factor for their application. Limiting factors for glycolipid synthesis in DES are not generally well understood. Therefore, the influence of external mass transfer, fatty acid concentration, and distribution on initial reaction velocity in two hydrophilic DES (choline:urea and choline:glucose) was investigated. At agitation speeds of and higher than 60 rpm, the viscosity of both DES did not limit external mass transfer. Fatty acid concentration of 0.5 M resulted in highest initial reaction velocity while higher concentrations had negative effects. Fatty acid accessibility was identified as a limiting factor for glycolipid synthesis in hydrophilic DES. Mean droplet sizes of fatty acid-DES emulsions can be significantly decreased by ultrasonic pretreatment resulting in significantly increased initial reaction velocity and yield (from 0.15 ± 0.03 μmol glucose monodecanoate/g DES to 0.57 ± 0.03 μmol/g) in the choline: urea DES. The study clearly indicates that fatty acid accessibility is a limiting factor in enzymatic glycolipid synthesis in DES. Furthermore, it was shown that physical pretreatment of fatty acid-DES emulsions is mandatory to improve the availability of fatty acids

    Monitoramento da multidisciplinaridade no processo de transferência de tecnologia em uma universidade: proposta de análise de cluster

    Get PDF
    ABSTRACTThis paper discusses the management of the technology transfer process conducted by a Technology Transfer Office (TTO) of a federal public university. Patent co-authorship and multidisciplinarity were used as concepts to evaluate and monitor the quality of academic and practical contribution and their potential for commercial application, using descriptive statistics and cluster analysis. Considering only multidisciplinary patents, binary cluster analysis was conducted, using Jaccard similarity measurement and single linkage method to determine proximity among academic units. Apart from the analysis of the number of patents, the approach enabled discussions and questions regarding the differences between patent generation patterns, resultant from the specific organizational culture and structures. The discussions are relevant to improve the identification of opportunities in technology transfer processes by the TTO

    Госпіталі на Переяславщині в роки Великої Вітчизняної війни (1941/1943 рр.)

    Get PDF
    У статті подано перелік тимчасових польових пересувних госпіталів, які функціонували в Переяславському районі Київської області під час Великої Вітчизняної війни, а саме в 1941 та в 1943 роках, досліджується історія евакуаційного госпіталю №2028, який був сформований у Переяславі, та висвітлюється виснажлива робота медичних працівників цього лікувального закладу.В статье дается перечень временных полевых передвижных госпиталей, которые функционировали в Переяславском районе Киевской области во время Великой Отечественной войны, а именно в 1941 и в 1943 годах, исследуется история эвакуационного госпиталя №2028, который был сформирован в Переяславе, и освещается изнурительная работа медицинских работников этого лечебного учреждения.The article informs about all temporary hospitals, which existed during the 2 World War in the area of Pereyaslav in Kyiv region. It shows the evacuation history from the year 1941 till 1943 of the temporary hospital №2028, that has been organized in Pereyaslav. This article also shows the hard work of the medical workers

    Functional performance of mobile versus fixed bearing total knee prostheses: a randomised controlled trial

    Get PDF
    PURPOSE: The primary goal of this study was to assess the difference in active flexion between patients with a mobile versus a fixed bearing, cruciate retaining, and total knee arthroplasty. The study was designed as a randomised controlled multi-centre trial. METHODS: Participants were assigned to interventions by using block-stratified, random allocation. Outcome parameters were active flexion, passive flexion, and Knee Society Score (KSS). Outcome parameters were assessed preoperatively and at 3, 6, and 12 months postoperatively by an independent nurse. RESULTS: Ninety-two patients from one centre were included, 46 in each group. Active flexion was comparable for the two groups, 99.9° for the mobile bearing group and 101° for the fixed bearing group with a baseline controlled difference of 1.0 (95% CI −3.9 to 5.8, n.s.). The Clinical KSS was comparable between the two bearing groups (Mobile 90.0 vs. fixed 92.4, n.s.). The functional KSS showed a difference that was attributable to the stair climbing subscore, which showed a difference in favour of the fixed bearing design between preoperative and 3 months (7.3 point difference; 95% CI 2.3–12.5; P = 0.005) as well as 12 months (4.8 point difference; 95% CI 0.1–9.6; P = 0.045). CONCLUSIONS: There were no short-term differences in active flexion between fixed bearing and mobile bearing total knee arthroplasty. LEVEL OF EVIDENCE: I

    Юрій Іллєнко (1936–2010)

    Get PDF
    15 червня помер Юрій Іллєнко – кінематографіст Божою милістю, чия творчість давно стала класикою вітчизняного і світового кіно

    Vision Screening in Children Aged 6 Months to 5 Years: Evidence Report and Systematic Review for the US Preventive Services Task Force

    Get PDF
    Importance: Preschool vision screening could allow detection and treatment of vision abnormalities during a critical developmental stage, preserving function and quality of life. Objective: To review the evidence on screening for and treatment of amblyopia, its risk factors, and refractive error in children aged 6 months to 5 years to inform the US Preventive Services Task Force. Data Sources: MEDLINE, Cochrane Library, CINAHL, and trial registries through June 2016; references; and experts, with surveillance of the literature through June 7, 2017. Study Selection: English-language randomized clinical trials (RCTs) or prospective cohort studies that evaluated screening, studies evaluating test accuracy, RCTs of treatment vs inactive controls, and cohort studies or case-control studies assessing harms. Data Extraction and Synthesis: Dual review of abstracts, full-text articles, and study quality; qualitative synthesis of findings. Studies were not quantitatively pooled because of clinical and methodological heterogeneity. Main Outcomes and Measures: Visual acuity, amblyopia, school performance, functioning, quality of life, test accuracy, testability, and harms. Results: Forty studies were included (N = 34 709); 34 evaluated test accuracy. No RCTs compared screening with no screening, and no studies evaluated school performance, function, or quality of life. Studies directly assessing earlier or more intensive screening were limited by high attrition. Positive likelihood ratios were between 5 and 10 for amblyopia risk factors or nonamblyogenic refractive error in most studies of test accuracy and were greater than 10 in most studies evaluating combinations of clinical tests. Inability to cooperate may limit use of some tests in children younger than 3 years. Studies with low prevalence (75%). Among children with amblyopia risk factors (eg, strabismus or anisometropia), patching improved visual acuity of the amblyopic eye by a mean of less than 1 line on a standard chart after 5 to 12 weeks for children pretreated with glasses (2 RCTs, 240 participants); more children treated with patching than with no patching experienced improvement of at least 2 lines (45% vs 21%; P = .003; 1 RCT, 180 participants). Patching plus glasses improved visual acuity by about 1 line after 1 year (0.11 logMAR [95% CI, 0.05-0.17]) for children not pretreated with glasses (1 RCT, 177 participants). Glasses alone improved visual acuity by less than 1 line after 1 year (0.08 logMAR [95% CI, 0.02-0.15], 1 RCT, 177 participants). Conclusions and Relevance: Studies directly evaluating the effectiveness of screening were limited and do not establish whether vision screening in preschool children is better than no screening. Indirect evidence supports the utility of multiple screening tests for identifying preschool children at higher risk for vision problems and the effectiveness of some treatments for improving visual acuity outcomes

    Optimising computer aided detection to identify intra-thoracic tuberculosis on chest x-ray in South African children

    Get PDF
    Diagnostic tools for paediatric tuberculosis remain limited, with heavy reliance on clinical algorithms which include chest x-ray. Computer aided detection (CAD) for tuberculosis on chest x-ray has shown promise in adults. We aimed to measure and optimise the performance of an adult CAD system, CAD4TB, to identify tuberculosis on chest x-rays from children with presumptive tuberculosis. Chest x-rays from 620 children <13 years enrolled in a prospective observational diagnostic study in South Africa, were evaluated. All chest x-rays were read by a panel of expert readers who attributed each with a radiological reference of either 'tuberculosis' or 'not tuberculosis'. Of the 525 chest x-rays included in this analysis, 80 (40 with a reference of 'tuberculosis' and 40 with 'not tuberculosis') were allocated to an independent test set. The remainder made up the training set. The performance of CAD4TB to identify 'tuberculosis' versus 'not tuberculosis' on chest x-ray against the radiological reference read was calculated. The CAD4TB software was then fine-tuned using the paediatric training set. We compared the performance of the fine-tuned model to the original model. Our findings were that the area under the receiver operating characteristic curve (AUC) of the original CAD4TB model, prior to fine-tuning, was 0.58. After fine-tuning there was an improvement in the AUC to 0.72 (p = 0.0016). In this first-ever description of the use of CAD to identify tuberculosis on chest x-ray in children, we demonstrate a significant improvement in the performance of CAD4TB after fine-tuning with a set of well-characterised paediatric chest x-rays. CAD has the potential to be a useful additional diagnostic tool for paediatric tuberculosis. We recommend replicating the methods we describe using a larger chest x-ray dataset from a more diverse population and evaluating the potential role of CAD to replace a human-read chest x-ray within treatment-decision algorithms for paediatric tuberculosis

    Performance of binary prediction models in high-correlation low-dimensional settings:a comparison of methods

    Get PDF
    BACKGROUND: Clinical prediction models are developed widely across medical disciplines. When predictors in such models are highly collinear, unexpected or spurious predictor-outcome associations may occur, thereby potentially reducing face-validity of the prediction model. Collinearity can be dealt with by exclusion of collinear predictors, but when there is no a priori motivation (besides collinearity) to include or exclude specific predictors, such an approach is arbitrary and possibly inappropriate. METHODS: We compare different methods to address collinearity, including shrinkage, dimensionality reduction, and constrained optimization. The effectiveness of these methods is illustrated via simulations. RESULTS: In the conducted simulations, no effect of collinearity was observed on predictive outcomes (AUC, R(2), Intercept, Slope) across methods. However, a negative effect of collinearity on the stability of predictor selection was found, affecting all compared methods, but in particular methods that perform strong predictor selection (e.g., Lasso). Methods for which the included set of predictors remained most stable under increased collinearity were Ridge, PCLR, LAELR, and Dropout. CONCLUSIONS: Based on the results, we would recommend refraining from data-driven predictor selection approaches in the presence of high collinearity, because of the increased instability of predictor selection, even in relatively high events-per-variable settings. The selection of certain predictors over others may disproportionally give the impression that included predictors have a stronger association with the outcome than excluded predictors. SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1186/s41512-021-00115-5
    corecore