320 research outputs found

    Aprotinin reduces cardiac troponin I release and inhibits apoptosis of polymorphonuclear cells during off-pump coronary artery bypass surgery

    Get PDF
    Objectives: In addition to blood-sparing effects, aprotinin may have cardioprotective and anti-inflammatory effects during cardiopulmonary bypass-assisted cardiac surgery. In this study, the authors examined whether aprotinin had cardioprotective and/or anti-inflammatory effects in patients undergoing off-pump coronary artery bypass grafting. Design: A prospective randomized clinical trial. Setting: University hospital. Participants: Fifty patients were randomized to control (n = 25) or aprotinin treatment (n = 25) groups. Interventions: Aprotinin was given as a loading dose (2 x 10(6) KIU) followed by a continuous infusion at 5 x 10(5) KIU/h until skin closure. Measurements and Main Results: Blood samples for cardiac troponin I; interleukin-6, interleukin-8, and interleukin-10; tumor necrosis factor a; and elastase were taken after anesthesia induction, completion of revascularization, and 6 hours, 12 hours, and 24 hours after revascularization. Blood samples were taken to assess for apoptosis in polymorphonuclear cells. Baseline plasma levels for cardiac troponin I did not differ between groups but were significantly lower in aprotinin-treated patients at the time of revascularization (P = 0.03) and 6 hours (p = 0.004) and 24 hours (p = 0.03) later. Aprotinin significantly reduced apoptosis in polymorphonuclear cells compared with control-treated patients (p = 0.04). There were no differences in plasma cytokine or elastase levels between groups. Conclusions: The authors conclude that aprotinin reduces perioperative cardiac troponin I release and attenuates apoptosis in polymorphonuclear cells but has no significant effects on plasma cytokine levels in patients undergoing off-pump coronary artery bypass graft surgery

    Infective endocarditis in patients after percutaneous pulmonary valve implantation with the stent-mounted bovine jugular vein valve : clinical experience and evaluation of the modified Duke criteria

    Get PDF
    Percutaneous pulmonary valve implantation (PPVI) has proven good hemodynamic results. As infective endocarditis (IE) remains a potential complication with limited available clinical data, we reviewed our patient records to improve future strategies of IE prevention, diagnosis and treatment. Medical records of all patients diagnosed with Melody® valve IE according to the modified Duke criteria were retrospectively analyzed in three Belgian tertiary centers. 23 IE episodes in 22 out of 240 patients were identified (incidence 2.4% / patient year) with a clear male predominance (86%). Median age at IE was 17.9 years (range 8.2-45.9 years) and median time from PPVI to IE was 2.4 years (range 0.7-8 years). Streptococcal species caused 10 infections (43%), followed by Staphylococcus aureus (n = 5, 22%). In 13/23 IE episodes a possible entry-point was identified (57%). IE was classified as definite in 15 (65%) and as possible in 8 (35%) cases due to limitations of imaging. Echocardiography visualized vegetations in only 10 patients. PET-CT showed positive FDG signals in 5/7 patients (71%) and intracardiac echocardiography a vegetation in 1/1 patient (100%). Eleven cases (48%) had a hemodynamically relevant pulmonary stenosis at IE presentation. Nine early and 6 late percutaneous or surgical re-interventions were performed. No IE related deaths occurred. IE after Melody® valve PPVI is associated with a relevant need of re-interventions. Communication to patients and physicians about risk factors is essential in prevention. The modified Duke criteria underperformed in diagnosing definite IE, but inclusion of new imaging modalities might improve diagnostic performance

    The search for valved conduit tissue grafts for adults (>22 mm): an ultrasonographic study of jugular vein diameters of horses and cattle

    Get PDF
    BACKGROUND: Natural heterologous valved conduits with a diameter greater than 22 mm that can be used for right ventricular outflow tract reconstruction in adults are not commercially available. The purpose of this study was to measure by ultrasonography the maximum diameter of the distended jugular veins of horses and cattle, respectively, to identify a population of animals that would be suitable for post-mortem collection of jugular veins at sizes greater than 22 mm. METHODS: The study population included 60 Warmblood horses, 25 Freiberger horses, 20 Brown Swiss cows, and 20 Holstein cows (including 10 Holstein and 10 Red Holstein). The maximum cross-sectional diameter of the distended jugular veins was measured at a location half-way between the mandibular angle and the thoracic inlet. The thoracic circumference (heart girth length) was used as a surrogate of body size. The jugular vein diameters of the different populations were compared by analysis of variance and the association between heart girth length and jugular vein diameter was determined in each of the four study populations by linear regression analysis. RESULTS: There was considerable individual variation of jugular vein diameters within each of the four study populations. There was no statistically significant relationship between thoracic circumference and jugular vein diameter in any of the populations. The jugular vein diameters of Brown Swiss cows were significantly larger than those of any of the other populations. Warmblood horses had significantly larger jugular vein diameters compared to Freiberger horses. CONCLUSION: The results of this study suggest that the production of bovine or equine xenografts with diameters of greater than 22 mm would be feasible. Differences between species and breeds need to be considered. However, prediction of the jugular vein diameter based on breed and heart girth length in an individual animal is inaccurate

    Intima Sarcoma of the Pulmonary Artery Mimicking Takayasu Disease

    Get PDF
    Pulmonary artery intima sarcoma is an uncommon but fatal tumor, which often masquerades chronic thromboembolic pulmonary hypertension (CTEPH) and in the present case Takayasu arteritis. Pulmonary arterial pressure is mildly elevated in the presence of extensive proximal lesions. A parenchyma thin-walled cavitary lesion may be a sign of pulmonary extravasation of the tumor

    Critical coarctation of the aorta in selective fetal growth restriction and the role of coronary stent implantation

    Get PDF
    Introduction:Monochorionic twins are at increased risk of congenital heart defects (CHDs). Up to 26% have a birth weight <1,500 g, a CHD requiring neonatal surgery, therefore, poses particular challenges.Objective:The aim of the study was to describe pregnancy characteristics, perinatal management, and outcome of monochorionic twins diagnosed with critical coarctation of the aorta (CoA).Methods:We included monochorionic twins diagnosed with critical CoA (2010-2019) at 2 tertiary referral centers, and we systematically reviewed the literature regarding CoA in monochorionic twins.Results:Seven neonates were included. All were the smaller twin of pregnancies complicated by selective fetal growth restriction. The median gestational age at birth was 32 weeks (28-34). Birth weight of affected twins ranged as 670-1,800 g. One neonate underwent coarctectomy at the age of 1 month (2,330 g). Six underwent stent implantation, performed between day 8 and 40, followed by definitive coarctectomy between 4 and 9 months in 4. All 7 developed normally, except for 1 child with neurodevelopmental delay. Three co-twins had pulmonary stenosis, of whom 1 required balloon valvuloplasty. The literature review revealed 10 cases of CoA, all in the smaller twin. Six cases detected in the first weeks after birth were treated with prostaglandins alone, by repeated transcatheter angioplasty or by surgical repair, with good outcome in 2 out of 6.Conclusions:CoA specifically affects the smaller twin of growth discordant monochorionic twin pairs. Stent implantation is a feasible bridging therapy to surgery in these low birth weight neonates.Research into fetal development and medicin

    The European Registry for Patients with Mechanical Circulatory Support (EUROMACS)

    Get PDF
    OBJECTIVES: A second paediatric report has been generated from the European Registry for Patients with Mechanical Circulatory Support (EUROMACS). The purpose of EUROMACS, which is operated by the European Association for Cardio-Thoracic Surgery, is to gather data related to durable mechanical circulatory support for scientific purposes and to publish reports with respect to the course of mechanical circulatory support therapy. Since the first report issued, efforts to increase compliance and participation have been extended. Additionally, the data provided the opportunity to analyse patients of younger age and lower weight. METHODS: Participating hospitals contributed pre-, peri- and long-term postoperative data on mechanical circulatory support implants to the registry. Data for all implants in paediatric patients (≤19 years of age) performed from 1 January 2000 to 1 July 2019 were analysed. This report includes updates of patient characteristics, implant frequency, outcome (including mortality rates, transplants and recovery rates) as well as adverse events including neurological dysfunction, device malfunction, major infection and bleeding. RESULTS: Twenty-nine hospitals contributed 398 registered implants in 353 patients (150 female, 203 male) to the registry. The most frequent aetiology of heart failure was any form of cardiomyopathy (61%), followed by congenital heart disease and myocarditis (16.4% and 16.1%, respectively). Competing outcomes analysis revealed that a total of 80% survived to transplant or recovery or are ongoing; at the 2-year follow-up examination, 20% died while on support. At 12 months, 46.7% received transplants, 8.7% were weaned from their device and 18.5% died. The 3-month adverse events rate was 1.69 per patient-year for device malfunction including pump exchange, 0.48 for major bleeding, 0.64 for major infection and 0.78 for neurological events. CONCLUSIONS: The overall survival rate was 81.5% at 12 months following ventricular assist device implant. The comparison of survival rates of the early and later eras shows no significant difference. A focus on specific subgroups showed that survival was less in patients of younger age (<1 year of age) (P = 0.01) and lower weight (<20 kg) (P = 0.015). Transplant rates at 6 months contin

    Impact of concomitant aortic valve replacement in patients with mild-to-moderate aortic valve regurgitation undergoing left ventricular assist device implantation: EUROMACS analysis

    Get PDF
    Introduction: Left ventricular assist device (LVAD) therapy may lead to an aortic regurgitation, limiting left ventricular unloading and causing adverse events. Whether concomitant aortic valve replacement may improve outcomes in patients with preoperative mild-to-moderate aortic regurgitation remains unclear. Methods: A retrospective propensity score-matched analysis of adult patients with preoperative mild-to-moderate aortic regurgitation undergoing durable LVAD implantation between 01/01/2011 and 30/11/2021 was performed. Patients undergoing concomitant valve surgery other than biological aortic valve replacement were excluded, resulting in 77 with concomitant biological aortic valve replacement and 385 without. Results: Following 1:1 propensity score matching, two groups of 55 patients with and without biological aortic valve replacement were obtained, (mean age 59 ± 11 years, 92% male, 59.1% HeartWare). Aortic regurgitation was mild in 72.7% and 76.4% and moderate in 27.3% and 23.6% in non-replacement and replacement cohorts respectively. The 30-day survival was 89.1% vs. 85.5% (p = 0.59), 1-year survival 69.1% vs. 56.4% (p = 0.19), and 2-year survival 61.8% vs. 47.3% (p = 0.10) in the non-replacement and replacement groups, respectively. After a mean follow-up of 1.2 years, non-replacement patients had a higher incidence of pump thrombosis (11 [20%] vs. 3 [5.5%], p = 0.022) and fewer major bleedings (2 [3.6%] vs. 11 [20%], p = 0.008). Conclusion: Compared with those treated conservatively, patients with mild-to-moderate aortic regurgitation undergoing concomitant aortic valve replacement during LVAD implantation have a similar survival up to 2 years on support. Patients with concomitant valve replacement had a higher risk of bleeding complications but fewer pump thromboses

    Causes and predictors of early mortality in patients treated with left ventricular assist device implantation in the European Registry of Mechanical Circulatory Support (EUROMACS)

    Get PDF
    Purpose: The aim of the study was to analyze early mortality after continuous-flow left ventricular assist device (LVAD) implantation which remains high. Methods: We analyzed consecutive (n = 2689) patients from the European Registry for Patients with Mechanical Circulatory Support (EUROMACS) undergoing continuous-flow LVAD implantation. The primary outcome was early (< 90 days) mortality. Secondary outcomes were differential causes of early post-operative death following LVAD implantation. Results: Univariable and multivariable analysis as well as regression analysis were used to examine determinants and differential causes of early (< 90 days) mortality after LVAD implantation. During the first 90 days, 2160 (80%) patients were alive with ongoing LVAD support, 40(2%) patients underwent heart transplantation, and 487(18%) deceased. The main causes of early death were MOF (36%), sepsis (28%), cardiopulmonary failure (CPF; 10%), CVA (9%), and right-sided heart failure (RHF, 8%). Furthermore, MOF and sepsis are 70% of causes of death in the first week. Independent clinical predictors of early death were age, female sex, INTERMACS profile 1 to 3, and ECMO. Laboratory predictors included elevated serum creatinine, total bilirubin, lactate, and low hemoglobin. Furthermore, hemodynamic predictors included elevated RA-to-PCWP ratio, pulmonary vascular resistance, and low systemic vascular resistance. Longer total implantation time was also independent predictor of early mortality. A simple model of 12 variables predicts early mortality following LVAD implantation with a good discriminative power with area under the curve of 0.75. Conclusions: In the EUROMACS registry, approximately one out of five patients die within 90 days after LVAD implantation. Early mortality is primarily dominated by multiorgan failure followed by sepsis. A simple model identifies important parameters which are associated with early mortality following LVAD implantation

    A European study on decellularized homografts for pulmonary valve replacement: initial results from the prospective ESPOIR Trial and ESPOIR Registry data\u2020

    Get PDF
    OBJECTIVES: Decellularized pulmonary homografts (DPH) have shown excellent results for pulmonary valve replacement. However, controlled multicentre studies are lacking to date.METHODS: Prospective European multicentre trial evaluating DPH for pulmonary valve replacement. Matched comparison of DPH to bovine jugular vein (BJV) conduits and cryopreserved homografts (CH) considering patient age, type of heart defect and previous procedures.RESULTS: In total, 121 patients (59 female) were prospectively enrolled (August 2014-December 2016), age 21.3 +/- 14.4 years, DPH diameter 24.4 +/- 2.8 mm. No adverse events occurred with respect to surgical handling; there were 2 early deaths (30 + 59 years) due to myocardial failure after multi-valve procedures and no late mortality (1.7% mortality). After a mean follow-up of 2.2 +/- 0.6 years, the primary efficacy end points mean peak gradient (16.1 +/- 12.1 mmHg) and regurgitation (mean 0.25 +/- 0.48, grade 0-3) were excellent. One reoperation was required for recurrent subvalvular stenosis caused by a pericardial patch and 1 balloon dilatation was performed on a previously stented LPA. 100% follow-up for DPH patients operated before or outside the trial (n = 114) included in the ESPOIR Registry, age 16.6 +/- 10.4 years, diameter 24.1 +/- 4.2 mm, follow-up 5.1 +/- 3.0 years. The combined DPH cohort, n = 235, comprising both Trial and Registry data showed significantly better freedom from explantation (DPH 96.7 +/- 2.1%, CH 84.4 +/- 3.2%, P = 0.029 and BJV 82.7 +/- 3.2%, P = 0.012) and less structural valve degeneration at 10 years when matched to CH, n = 235 and BJV, n = 235 (DPH 61.4 +/- 6.6%, CH 39.9 +/- 4.4%, n.s., BJV 47.5 +/- 4.5%, P = 0.029).CONCLUSIONS: Initial results of the prospective multicentre ESPOIR Trial showed DPH to be safe and efficient. Current DPH results including Registry data were superior to BJV and CH.Thoracic Surger

    Contegra conduit for reconstruction of the right ventricular outflow tract: a review of published early and mid-time results

    Get PDF
    <p>Abstract</p> <p>Objective</p> <p>The valved conduit Contegra (bovine jugular vein) has being implanted for more than 7 years in the right ventricular outflow tract and it is noted that the available reports have been mixed. The aim of this study is to review the reported evidence in the literature.</p> <p>Methods</p> <p>Search of the relevant literature for the primary endpoints of operative mortality and morbidity and secondary endpoints of follow-up haemodynamic performance including severe stenosis, regurgitation and need for reintervention are presented.</p> <p>Results</p> <p>We selected and analysed 17 series including 767 patients. Commonest indication was Fallot's tetralogy. Operative mortality was 2.6%. Operative morbidity was 13.9%. In follow-up, the incidence of intraconduit stenosis was 10.9% (incidence of stenosis for the 12 millimetre conduit was 83.3% in one series) and that of at least moderate regurgitation was 6.3%.</p> <p>The aspirin users had a stenosis incidence of 10.5% compared to the non-users had a stenosis incidence of 9.6%.</p> <p>Conclusion</p> <p>A dissent on the performance of the Contegra is discussed, while results are satisfactory in the majority of studies apart for the smallest conduits (12 and 14 millimetre), suggesting an association to compromised run-off. The role of aspirin as antithrombotic modulator remains controversial.</p
    corecore