619 research outputs found

    Zeolite-dye micro lasers

    Get PDF
    We present a new class of micro lasers based on nanoporous molecular sieve host-guest systems. Organic dye guest molecules of 1-Ethyl-4-(4-(p-Dimethylaminophenyl)-1,3-butadienyl)-pyridinium Perchlorat were inserted into the 0.73-nm-wide channel pores of a zeolite AlPO4_4-5 host. The zeolitic micro crystal compounds where hydrothermally synthesized according to a particular host-guest chemical process. The dye molecules are found not only to be aligned along the host channel axis, but to be oriented as well. Single mode laser emission at 687 nm was obtained from a whispering gallery mode oscillating in a 8-Ό\mum-diameter monolithic micro resonator, in which the field is confined by total internal reflection at the natural hexagonal boundaries inside the zeolitic microcrystals.Comment: Accepted for publication in Phys. Rev. Let

    Eddy Current Thickness Measurement of the Zink Layer on Galvanized Steel Wires

    Get PDF
    By resolving Maxwell’s Equations for the case of a long coil encircling a galvanized wire (fig.l), we can calculate the normalized impedance diagram. Later, during the experiments, we will directly use this diagram to find the thickness of the zinc layer. Before resolving Maxwell’s Equations, a few words about the normalized impedance diagram in general. Figure 2 shows the normalized impedance diagram for the simple case of a long coil encircling a wire made out of a homogeneous conductive material of permeability ”r and with a fill factor equal to one. A fill factor, η=a2/c2 (fig. 3), equal to one, means that there is no air between the coil and the wire. The x axis represents the normalized resistance (1) (Rp−Re)/ωLe, where Rp is the real component of the impedance Zp of the coil when there is a part inside the coil, Re and ωLe are respectively the real and the imaginary components of Ze when the coil is empty

    Diagnostic performance of transthyretin measurement in fat tissue of patients with ATTR amyloidosis

    Get PDF
    In this article, the diagnostic performance of a transthyretin (TTR) ELISA for detection and characterization of transthyretin-derived (ATTR) amyloid in abdominal subcutaneous fat tissue was studied. Fat tissue specimens were analyzed of 38 patients with ATTR amyloidosis, 70 controls, and 17 carriers of a TTR mutation. Amyloid amount was graded semi-quantitatively in Congo red-stained specimens (0-4+). Amyloid was extracted from tissue in guanidine, and the TTR concentration was measured using a sandwich TTR-ELISA. The TTR concentration of patients with ATTR amyloidosis (mean 0.84 ng/mg fat tissue) was significantly higher than controls (p<0.001). With a TTR concentration of 0.13 ng/mg fat tissue as cut-off value, 32 of the 38 ATTR patients were identified resulting in a sensitivity of 84%. Sixty-seven of the 70 controls had values below the cut-off value resulting in a specificity of 96%. Thus, measuring TTR in fat tissue is useful for detecting ATTR amyloidosis and for characterizing amyloid as ATTR type

    Catalytic photoinduced electron transport across a lipid bilayer mediated by a membrane-soluble electron relay

    Get PDF
    Unidirectional photocatalytic electron transfer from a hydrophilic electron donor encapsulated in the interior of a liposome, to a hydrophilic electron acceptor on the other side of the membrane, has been achieved using the simple membrane-soluble electron relay 1-methoxy-N-methylphenazinium (MMP+). The total amount of photoproduct (>140 nmol) exceeds the number of moles of MMP+ present (125 nmol), thus showing that the transport of electrons is catalytic.Metals in Catalysis, Biomimetics & Inorganic Material

    Interactions of Ar(9+) and metastable Ar(8+) with a Si(100) surface at velocities near the image acceleration limit

    Full text link
    Auger LMM spectra and preliminary model simulations of Ar(9+) and metastable Ar(8+) ions interacting with a clean monocrystalline n-doped Si(100) surface are presented. By varying the experimental parameters, several yet undiscovered spectroscopic features have been observed providing valuable hints for the development of an adequate interaction model. On our apparatus the ion beam energy can be lowered to almost mere image charge attraction. High data acquisition rates could still be maintained yielding an unprecedented statistical quality of the Auger spectra.Comment: 34 pages, 11 figures, http://pikp28.uni-muenster.de/~ducree

    Oregon Community-Based Care Survey 2016: Adult Foster Homes

    Get PDF
    This report describes adult foster homes in Oregon. An adult foster home (AFH) is a type of licensed community-based care (CBC) setting that provides residential, personal care, and health-related services, primarily to older adults. The study collected information from adult foster homes to achieve the following four main goals. Describe adult foster home characteristics, including staffing types and levels, policies, and monthly charges and fees Describe current residents’ health and social characteristics Compare current results to prior Oregon surveys and to national studies of similar setting types to identify changes and possible trends Compare setting types for differences that might affect access, quality, or costs The study findings are intended to provide information that state agency staff, legislators, community-based care providers, and consumers may use to guide their decisions. Providing state-level information was one of the goals of Oregon’s LTC 3.0 planning process

    Rapid Assessment of Avoidable Blindness in India

    Get PDF
    BACKGROUND: Rapid assessment of avoidable blindness provides valid estimates in a short period of time to assess the magnitude and causes of avoidable blindness. The study determined magnitude and causes of avoidable blindness in India in 2007 among the 50+ population. METHODS AND FINDINGS: Sixteen randomly selected districts where blindness surveys were undertaken 7 to 10 years earlier were identified for a follow up survey. Stratified cluster sampling was used and 25 clusters (20 rural and 5 urban) were randomly picked in each district.. After a random start, 100 individuals aged 50+ were enumerated and examined sequentially in each cluster. All those with presenting vision = 50 years were enumerated, and 94.7% examined. Based on presenting vision,, 4.4% (95% Confidence Interval[CI]: 4.1,4.8) were severely visually impaired (vision<6/60 to 3/60 in the better eye) and 3.6% (95% CI: 3.3,3.9) were blind (vision<3/60 in the better eye). Prevalence of low vision (<6/18 to 6/60 in the better eye) was 16.8% (95% CI: 16.0,17.5). Prevalence of blindness and severe visual impairment (<6/60 in the better eye) was higher among rural residents (8.2%; 95% CI: 7.9,8.6) compared to urban (7.1%; 95% CI: 5.0, 9.2), among females (9.2%; 95% CI: 8.6,9.8) compared to males (6.5%; 95% CI: 6.0,7.1) and people above 70 years (20.6%; 95% CI: 19.1,22.0) compared to people aged 50-54 years (1.3%; 95% CI: 1.1,1.6). Of all blindness, 88.2% was avoidable. of which 81.9% was due to cataract and 7.1% to uncorrected refractive errors/uncorrected aphakia. CONCLUSIONS: Cataract and refractive errors are major causes of blindness and low vision and control strategies should prioritize them. Most blindness and low vision burden is avoidable

    Connections to the Electrodes Control the Transport Mechanism in Single-Molecule Transistors.

    Get PDF
    When designing a molecular electronic device for a specific function, it is necessary to control whether the charge-transport mechanism is phase-coherent transmission or particle-like hopping. Here we report a systematic study of charge transport through single zinc-porphyrin molecules embedded in graphene nanogaps to form transistors, and show that the transport mechanism depends on the chemistry of the molecule-electrode interfaces. We show that van der Waals interactions between molecular anchoring groups and graphene yield transport characteristic of Coulomb blockade with incoherent sequential hopping, whereas covalent molecule-electrode amide bonds give intermediately or strongly coupled single-molecule devices that display coherent transmission. These findings demonstrate the importance of interfacial engineering in molecular electronic circuits

    Rapid assessment of visual impairment (RAVI) in marine fishing communities in South India - study protocol and main findings

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Reliable data are a pre-requisite for planning eye care services. Though conventional cross sectional studies provide reliable information, they are resource intensive. A novel rapid assessment method was used to investigate the prevalence and causes of visual impairment and presbyopia in subjects aged 40 years and older. This paper describes the detailed methodology and study procedures of Rapid Assessment of Visual Impairment (RAVI) project.</p> <p>Methods</p> <p>A population-based cross-sectional study was conducted using cluster random sampling in the coastal region of Prakasam district of Andhra Pradesh in India, predominantly inhabited by fishing communities. Unaided, aided and pinhole visual acuity (VA) was assessed using a Snellen chart at a distance of 6 meters. The VA was re-assessed using a pinhole, if VA was < 6/12 in either eye. Near vision was assessed using N notation chart binocularly. Visual impairment was defined as presenting VA < 6/18 in the better eye. Presbyopia is defined as binocular near vision worse than N8 in subjects with binocular distance VA of 6/18 or better.</p> <p>Results</p> <p>The data collection was completed in <12 weeks using two teams each consisting of one paramedical ophthalmic personnel and two community eye health workers. The prevalence of visual impairment was 30% (95% CI, 27.6-32.2). This included 111 (7.1%; 95% CI, 5.8-8.4) individuals with blindness. Cataract was the leading cause of visual impairment followed by uncorrected refractive errors. The prevalence of blindness according to WHO definition (presenting VA < 3/60 in the better eye) was 2.7% (95% CI, 1.9-3.5).</p> <p>Conclusion</p> <p>There is a high prevalence of visual impairment in marine fishing communities in Prakasam district in India. The data from this rapid assessment survey can now be used as a baseline to start eye care services in this region. The rapid assessment methodology (RAVI) reported in this paper is robust, quick and has the potential to be replicated in other areas.</p
    • 

    corecore