230 research outputs found

    Familial Aggregation of Urinary Tract and Bone Tumors: Searching for a Syndrome

    Get PDF
    Positive family anamnesis is an important risk factor for cancer, and therefore further investigations need to be done if familial aggregation of cancer is observed. Due to a rare combination of urinary tract and bone tumors occurring in the family presented herein we hypothesized a hereditary predisposition and thus, Li-Fraumeni syndrome was considered to be the most likely differential diagnosis. To confirm Li-Fraumeni syndrome, we set out to investigate this case by analyzing the tumor suppressor gene p53. However, taking into account all the diagnostic results obtained, Li-Fraumeni syndrome could not be confirmed, but there is still uncertainty regarding a definitive diagnosis

    Varying the item format improved the range of measurement in patient-reported outcome measures assessing physical function

    Get PDF
    BACKGROUND: Physical function (PF) is a core patient-reported outcome domain in clinical trials in rheumatic diseases. Frequently used PF measures have ceiling effects, leading to large sample size requirements and low sensitivity to change. In most of these instruments, the response category that indicates the highest PF level is the statement that one is able to perform a given physical activity without any limitations or difficulty. This study investigates whether using an item format with an extended response scale, allowing respondents to state that the performance of an activity is easy or very easy, increases the range of precise measurement of self-reported PF. METHODS: Three five-item PF short forms were constructed from the Patient-Reported Outcomes Measurement Information System (PROMIS(R)) wave 1 data. All forms included the same physical activities but varied in item stem and response scale: format A ( Are you able to ... ; without any difficulty / unable to do ); format B ( Does your health now limit you ... ; not at all / cannot do ); format C ( How difficult is it for you to ... ; very easy / impossible ). Each short-form item was answered by 2217-2835 subjects. We evaluated unidimensionality and estimated a graded response model for the 15 short-form items and remaining 119 items of the PROMIS PF bank to compare item and test information for the short forms along the PF continuum. We then used simulated data for five groups with different PF levels to illustrate differences in scoring precision between the short forms using different item formats. RESULTS: Sufficient unidimensionality of all short-form items and the original PF item bank was supported. Compared to formats A and B, format C increased the range of reliable measurement by about 0.5 standard deviations on the positive side of the PF continuum of the sample, provided more item information, and was more useful in distinguishing known groups with above-average functioning. CONCLUSIONS: Using an item format with an extended response scale is an efficient option to increase the measurement range of self-reported physical function without changing the content of the measure or affecting the latent construct of the instrument

    Validation of the prognostic relevance of plasma C-reactive protein levels in soft-tissue sarcoma patients

    Get PDF
    Background: The concept of the involvement of systemic inflammation in cancer progression and metastases has gained attraction within the past decade. C-reactive protein (CRP), a non-specific blood-based marker of the systemic inflammatory response, has been associated with decreased survival in several cancer types. The aim of the present study was to validate the prognostic value of pre-operative plasma CRP levels on clinical outcome in a large cohort of soft-tissue sarcoma (STS) patients. Methods: Three hundred and four STS patients, operated between 1998 and 2010, were retrospectively evaluated. CRP levels and the impact on cancer-specific survival (CSS), disease-free survival (DFS) and overall survival (OS) were assessed using Kaplan–Meier curves and univariate as well as multivariate Cox proportional models. Additionally, we developed a nomogram by supplementing the plasma CRP level to the well-established Kattan nomogram and evaluated the improvement of predictive accuracy of this novel nomogram by applying calibration and Harrell’s concordance index (c-index). Results: An elevated plasma CRP level was significantly associated with established prognostic factors, including age, tumour grade, size and depth (P<0.05). In multivariate analysis, increased CRP levels were significantly associated with a poor outcome for CSS (HR=2.05; 95% CI=1.13–3.74; P=0.019) and DFS (HR=1.88; 95% CI=1.07–3.34; P=0.029). The estimated c-index was 0.74 using the original Kattan nomogram and 0.77 when the plasma CRP level was added. Conclusion: An elevated pre-operative CRP level represents an independent prognostic factor that predicts poor prognosis and improves the predictive ability of the Kattan nomogram in STS patients. Our data suggest to further prospectively validate its potential utility for individual risk stratification and clinical management of STS patients

    a protocol for developing a patient-reported outcome measurement instrument

    Get PDF
    Introduction: There is no consensus about what constitutes the most appropriate patient-reported outcome measurement (PROM) instrument for measuring physical function in patients with rheumatic hand conditions. Existing instruments lack psychometric testing and vary in feasibility and their psychometric qualities. We aim to develop a PROM instrument to assess hand-related physical function in rheumatic hand conditions. Methods and analysis: We will perform a systematic search to identify existing PROMs to rheumatic hand conditions, and select items relevant for hand-related physical function as well as those items from the Patient Reported Outcomes Measurement Information System (PROMIS) Physical Function (PF) item bank that are relevant to patients with rheumatic hand conditions. Selection will be based on consensus among reviewers. Content validity of selected items will be established through the use of focus groups. If patients deem necessary, we will develop new items based on the patients' input. We will examine whether it is valid to score all selected and developed items on the same scale as the original items from the PROMIS PF item bank. Our analyses will follow the methods used for calibrating the original PROMIS PF item bank in US samples, which were largely based on the general PROMIS approach. Ethics and dissemination: This study will be carried out in accordance with the Helsinki Declaration. Ethics approvals will be obtained where necessary, and signed informed consent will be obtained from all participants. We aim to disseminate the results of the study through publication in international peer-reviewed journals and at international conferences

    General population normative data for the EORTC QLQ-C30 health-related quality of life questionnaire based on 15,386 persons across 13 European countries, Canada and the Unites States

    Get PDF
    OBJECTIVE: The European Organisation for Research and Treatment of Cancer (EORTC) QLQ-C30 health-related quality of life questionnaire is one of the most widely used cancer-specific health-related quality of life questionnaires worldwide. General population norm data can facilitate the interpretation of QLQ-C30 data obtained from cancer patients. This study aimed at systematically collecting norm data from the general population to develop European QLQ-C30 norm scores and to generate comparable norm data for individual countries in Europe and North America. METHODS: We collected QLQ-C30 data from the general population across 11 European Union (EU) countries, Russia, Turkey, Canada and United States (n \u3e /= 1000/country). Representative samples were stratified by sex and age groups (18-39, 40-49, 50-59, 60-69 and \u3e /= 70 years). After applying weights based on the United Nations population distribution statistics, we calculated QLQ-C30 domain scores to generate a \u27European QLQ-C30 Norm\u27 based on the EU countries. Further, we calculated QLQ-C30 norm scores for all 15 individual countries. RESULTS: A total of 15,386 respondents completed the online survey. For the EU sample, most QLQ-C30 domains showed differences by sex/age, with men scoring somewhat better health than women, while age effects varied across domains. Substantially larger differences were seen in inter-country comparisons, with Austrian and Dutch respondents reporting consistently better health compared with British and Polish respondents. CONCLUSIONS: This study is the first to systematically collect EORTC QLQ-C30 general population norm data across Europe and North America applying a consistent data collection method across 15 countries. These new norm data facilitate valid intra-country as well as inter-country comparisons and QLQ-C30 score interpretation

    Hand-related physical function in rheumatic hand conditions:a protocol for developing a patient-reported outcome measurement instrument

    Get PDF
    Introduction: There is no consensus about what constitutes the most appropriate patient-reported outcome measurement (PROM) instrument for measuring physical function in patients with rheumatic hand conditions. Existing instruments lack psychometric testing and vary in feasibility and their psychometric qualities. We aim to develop a PROM instrument to assess hand-related physical function in rheumatic hand conditions. Methods and analysis: We will perform a systematic search to identify existing PROMs to rheumatic hand conditions, and select items relevant for hand-related physical function as well as those items from the Patient Reported Outcomes Measurement Information System (PROMIS) Physical Function (PF) item bank that are relevant to patients with rheumatic hand conditions. Selection will be based on consensus among reviewers. Content validity of selected items will be established through the use of focus groups. If patients deem necessary, we will develop new items based on the patients' input. We will examine whether it is valid to score all selected and developed items on the same scale as the original items from the PROMIS PF item bank. Our analyses will follow the methods used for calibrating the original PROMIS PF item bank in US samples, which were largely based on the general PROMIS approach. Ethics and dissemination: This study will be carried out in accordance with the Helsinki Declaration. Ethics approvals will be obtained where necessary, and signed informed consent will be obtained from all participants. We aim to disseminate the results of the study through publication in international peer-reviewed journals and at international conferences

    Establishing the European Norm for the health-related quality of life domains of the computer-adaptive test EORTC CAT Core

    Get PDF
    OBJECTIVE: The computer-adaptive test (CAT) of the European Organisation for Research and Treatment of Cancer (EORTC), the EORTC CAT Core, assesses the same 15 domains as the EORTC QLQ-C30 health-related quality of life questionnaire but with increased precision, efficiency, measurement range and flexibility. CAT parameters for estimating scores have been established based on clinical data from cancer patients. This study aimed at establishing the European Norm for each CAT domain based on general population data. METHODS: We collected representative general population data across 11 European Union (EU) countries, Russia, Turkey, Canada and the United States (n \u3e /= 1000/country; stratified by sex and age). We selected item subsets from each CAT domain for data collection (totalling 86 items). Differential item functioning (DIF) analyses were conducted to investigate cross-cultural measurement invariance. For each domain, means and standard deviations from the EU countries (weighted by country population, sex and age) were used to establish a T-metric with a European general population mean = 50 (standard deviation = 10). RESULTS: A total of 15,386 respondents completed the online survey (n = 11,343 from EU countries). EORTC CAT Core norm scores for all 15 countries were calculated. DIF had negligible impact on scoring. Domain-specific T-scores differed significantly across countries with small to medium effect sizes. CONCLUSION: This study establishes the official European Norm for the EORTC CAT Core. The European CAT Norm can be used globally and allows for meaningful interpretation of scores. Furthermore, CAT scores can be compared with sex- and age-adjusted norm scores at a national level within each of the 15 countries
    • …
    corecore