278 research outputs found
Video guidance, landing, and imaging systems
The adaptive potential of video guidance technology for earth orbital and interplanetary missions was explored. The application of video acquisition, pointing, tracking, and navigation technology was considered to three primary missions: planetary landing, earth resources satellite, and spacecraft rendezvous and docking. It was found that an imaging system can be mechanized to provide a spacecraft or satellite with a considerable amount of adaptability with respect to its environment. It also provides a level of autonomy essential to many future missions and enhances their data gathering ability. The feasibility of an autonomous video guidance system capable of observing a planetary surface during terminal descent and selecting the most acceptable landing site was successfully demonstrated in the laboratory. The techniques developed for acquisition, pointing, and tracking show promise for recognizing and tracking coastlines, rivers, and other constituents of interest. Routines were written and checked for rendezvous, docking, and station-keeping functions
The upgraded data acquisition system for beam loss monitoring at the Fermilab Tevatron and Main Injector
A VME-based data acquisition system for beam-loss monitors has been developed
and is in use in the Tevatron and Main Injector accelerators at the Fermilab
complex. The need for enhanced beam-loss protection when the Tevatron is
operating in collider-mode was the main driving force for the new design. Prior
to the implementation of the present system, the beam-loss monitor system was
disabled during collider operation and protection of the Tevatron magnets
relied on the quench protection system. The new Beam-Loss Monitor system allows
appropriate abort logic and thresholds to be set over the full set of collider
operating conditions. The system also records a history of beam-loss data prior
to a beam-abort event for post-abort analysis. Installation of the Main
Injector system occurred in the fall of 2006 and the Tevatron system in the
summer of 2007. Both systems were fully operation by the summer of 2008. In
this paper we report on the overall system design, provide a description of its
normal operation, and show a number of examples of its use in both the Main
Injector and Tevatron.Comment: 24 page
An evolutionary stage model of outsourcing and competence destruction : a Triad comparison of the consumer electronics industry
Outsourcing has gained much prominence in managerial practice and academic discussions in the last two decades or so. Yet, we still do not understand the full implications of outsourcing strategy for corporate performance. Traditionally outsourcing across borders is explained as a cost-cutting exercise, but more recently the core competency argument states that outsourcing also leads to an increased focus, thereby improving effectiveness. However, no general explanation has so far been provided for how outsourcing could lead to deterioration in a firm‟s competence base. We longitudinally analyze three cases of major consumer electronics manufacturers, Emerson Radio from the U.S., Japan‟s Sony and Philips from the Netherlands to understand the dynamic process related to their sourcing strategies. We develop an evolutionary stage model that relates outsourcing to competence development inside the firm and shows that a vicious cycle may emerge. Thus it is appropriate to look not only at how outsourcing is influenced by an organization‟s current set of competences, but also how it alters that set over time. The four stages of the model are offshore sourcing, phasing out, increasing dependence on foreign suppliers, and finally industry exit or outsourcing reduction. The evolutionary stage model helps managers understand for which activities and under which conditions outsourcing across borders is not a viable option.
Results suggest that each of these firms had faced a loss of manufacturing competitiveness in its home country, to which it responded by offshoring and then outsourcing production. When a loss of competences occurred, some outsourcing decisions were reversed
HyperCP: A high-rate spectrometer for the study of charged hyperon and kaon decays
The HyperCP experiment (Fermilab E871) was designed to search for rare
phenomena in the decays of charged strange particles, in particular CP
violation in and hyperon decays with a sensitivity of
. Intense charged secondary beams were produced by 800 GeV/c protons
and momentum-selected by a magnetic channel. Decay products were detected in a
large-acceptance, high-rate magnetic spectrometer using multiwire proportional
chambers, trigger hodoscopes, a hadronic calorimeter, and a muon-detection
system. Nearly identical acceptances and efficiencies for hyperons and
antihyperons decaying within an evacuated volume were achieved by reversing the
polarities of the channel and spectrometer magnets. A high-rate
data-acquisition system enabled 231 billion events to be recorded in twelve
months of data-taking.Comment: 107 pages, 45 Postscript figures, 14 tables, Elsevier LaTeX,
submitted to Nucl. Instrum. Meth.
Internalisation Theory and outward direct investment by emerging market multinationals
The rise of multinational enterprises from emerging countries (EMNEs) poses an important test for theories of the multinational enterprise such as internalisation theory. It has been contended that new phenomena need new theory. This paper proposes that internalisation theory is appropriate to analyse EMNEs. This paper examines four approaches to EMNEs—international investment strategies, domestic market imperfections, international corporate networks and domestic institutions—and three case studies—Chinese outward FDI, Indian foreign acquisitions and investment in tax havens—to show the enduring relevance and predictive power of internalisation theory. This analysis encompasses many other approaches as special cases of internalisation theory. The use of internalisation theory to analyse EMNEs is to be commended, not only because of its theoretical inclusivity, but also because it has the ability to connect and to explain seemingly desperate phenomena
Bright green light treatment of depression for older adults [ISRCTN69400161]
BACKGROUND: Bright white light has been successfully used for the treatment of depression. There is interest in identifying which spectral colors of light are the most efficient in the treatment of depression. It is theorized that green light could decrease the intensity duration of exposure needed. Late Wake Treatment (LWT), sleep deprivation for the last half of one night, is associated with rapid mood improvement which has been sustained by light treatment. Because spectral responsiveness may differ by age, we examined whether green light would provide efficient antidepressant treatment in an elder age group. METHODS: We contrasted one hour of bright green light (1,200 Lux) and one hour of dim red light placebo (<10 Lux) in a randomized treatment trial with depressed elders. Participants were observed in their homes with mood scales, wrist actigraphy and light monitoring. On the day prior to beginning treatment, the participants self-administered LWT. RESULTS: The protocol was completed by 33 subjects who were 59 to 80 years old. Mood improved on average 23% for all subjects, but there were no significant statistical differences between treatment and placebo groups. There were negligible adverse reactions to the bright green light, which was well tolerated. CONCLUSION: Bright green light was not shown to have an antidepressant effect in the age group of this study, but a larger trial with brighter green light might be of value
Testing Meson Portal Dark Sector Solutions to the MiniBooNE Anomaly at CCM
A solution to the MiniBooNE excess invoking rare three-body decays of the
charged pions and kaons to new states in the MeV mass scale was recently
proposed as a dark-sector explanation. This class of solution illuminates the
fact that, while the charged pions were focused in the target-mode run, their
decay products were isotropically suppressed in the beam-dump-mode run in which
no excess was observed. This suggests a new physics solution correlated to the
mesonic sector. We investigate an extended set of phenomenological models that
can explain the MiniBooNE excess as a dark sector solution, utilizing
long-lived particles that might be produced in the three-body decays of the
charged mesons and the two-body anomalous decays of the neutral mesons. Over a
broad set of interactions with the long-lived particles, we show that these
scenarios can be compatible with constraints from LSND, KARMEN, and MicroBooNE,
and evaluate the sensitivity of the ongoing and future data taken by the
Coherent CAPTAIN Mills experiment (CCM) to a potential discovery in this
parameter space.Comment: 15 pages, 14 figures. Planned submission for PR
Bright light treatment of depression for older adults [ISRCTN55452501]
BACKGROUND: The incidence of insomnia and depression in the elder population is significant. It is hoped that use of light treatment for this group could provide safe, economic, and effective rapid recovery. METHODS: In this home-based trial we treated depressed elderly subjects with bright white (8,500 Lux) and dim red (<10 Lux) light for one hour a day at three different times (morning, mid-wake and evening). A placebo response washout was used for the first week. Wake treatment was conducted prior to the initiation of treatment, to explore antidepressant response and the interaction with light treatment. Urine and saliva samples were collected during a 24-hour period both before and after treatment and assayed for aMT6s and melatonin respectively to observe any change in circadian timing. Subjects wore a wrist monitor to record light exposure and wrist activity. Daily log sheets and weekly mood (GDS) and physical symptom (SAFTEE) scales were administered. Each subject was given a SCID interview and each completed a mood questionnaire (SIGH-SAD-SR) before and after treatment. Also, Hamilton Depression Rating (SIGH-SAD version) interviews were conducted by a researcher who was blind to the treatment condition. A control group of healthy, age-matched, volunteers was studied for one day to obtain baseline data for comparison of actigraphy and hormone levels. RESULTS: Eighty-one volunteers, between 60 and 79 years old, completed the study. Both treatment and placebo groups experienced mood improvement. Average GDS scores improved 5 points, the Hamilton Depression Rating Scale (HDRS) 17 scores (extracted from the self-rated SIGH-SAD-SR) improved 6 points. There were no significant treatment effects or time-by-treatment interactions. No significant adverse reactions were observed in either treatment group. The assays of urine and saliva showed no significant differences between the treatment and placebo groups. The healthy control group was active earlier and slept earlier but received less light than the depressed group at baseline. CONCLUSION: Antidepressant response to bright light treatment in this age group was not statistically superior to placebo. Both treatment and placebo groups experienced a clinically significant overall improvement of 16%
Composition of the Top Management Team and Firm International Diversification
This study investigates the impact of various top management team characteristics on firm international diversification. Relying on data from 126 firms in the electronics industry, we find that certain top management team characteristics are related to international expansion. Specifically, results indicate that lower average age, higher average tenure, higher average elite education, higher average international experience, and higher tenure heterogeneity are associated with firm international diversification. The study reinforces the importance of top management team composition in internationalization decisions and suggests further research in this context.Yeshttps://us.sagepub.com/en-us/nam/manuscript-submission-guideline
- …
