426 research outputs found

    Systematic feed-forward convolutional encoders are as good as other encoders with an M-algorithm decoder

    Get PDF
    In this paper we show that systematic convolutional encoders perform as well as nonsystematic ones when they are used together with M-algorithm decoders. We describe the algorithm and give a brief historical review

    Low cardiorespiratory fitness and obesity for ADHD in childhood and adolescence: A 6‐year cohort study

    Get PDF
    Attention-deficit/hyperactivity disorder (ADHD) is a prevalent disorder in childhood and identifying risk factors associated with developing ADHD during childhood and adolescence is relevant from a clinical and epidemiological point of view. This work examines (1) whether overweight/obesity and low cardiorespiratory fitness (CRF) are associated with increased ADHD symptoms in childhood (cross sectional analysis), and (2) whether overweight/obesity and low CRF levels during childhood predict increased ADHD symptoms in adolescence (longitudinal analysis). Data were examined from a longitudinal study of Estonian inhabitants who took part in the European Youth Heart Study (EYHS) in 1998 and 1999 (baseline age 9 years), who were re-evaluated 6 years later as part of the longitudinal Estonian Children Personality Behaviour and Health Study (ECPBHS). CRF was determined via an incremental maximal cycle-ergometer test, overweight/obesity was based on body mass index (BMI), and the 7-point af Klinteberg Hyperactivity Scale was used to assess ADHD symptoms at both time points. In the cross-sectional analysis, children with overweight/obesity were at greater risk of ADHD symptoms compared to underweight/normal-weight children, as were those unfit compared to fit children (OR=1.92 and 95%CI=1.02–3.55, and OR=1.84 and 95%CI=1.13–2.98, respectively). The cross-sectional association between BMI and ADHD symptoms was mediated by CRF (z=2.116, 42.9%; p=0.034). The longitudinal analysis showed being unfit in childhood was associated with a greater risk of increased ADHD symptoms 6 years later in adolescence (OR=2.26 and 95%CI=1.14–4.47), even after adjusting for baseline ADHD symptoms and BMI. Our result suggests that being unfit is an additional risk factor for increased ADHD symptoms during childhood and adolescence. The association between BMI and ADHD symptoms was mediated by CRF in the cross-sectional analysis and no association was seen between overweight/obesity and increased ADHD symptoms

    COMPATIBILITY OF ATMOSPHERIC (CO2)-C-14 MEASUREMENTS:COMPARING THE HEIDELBERG LOW-LEVEL COUNTING FACILITY TO INTERNATIONAL ACCELERATOR MASS SPECTROMETRY (AMS) LABORATORIES.

    Get PDF
    Combining atmospheric ∂14CO2 data sets from different networks or laboratories requires secure knowledge on their compatibility. In the present study, we compare ∂14CO2 results from the Heidelberg low-level counting (LLC) laboratory to 12 international accelerator mass spectrometry (AMS) laboratories using distributed aliquots of five pure CO2 samples. The averaged result of the LLC laboratory has a measurement bias of –0.3±0.5‰ with respect to the consensus value of the AMS laboratories for the investigated atmospheric ∂14C range of 9.6 to 40.4‰. Thus, the LLC measurements on average are not significantly different from the AMS laboratories, and the most likely measurement bias is smaller than the World Meteorological Organization (WMO) interlaboratory compatibility goal for ∂14CO2 of 0.5‰. The number of intercomparison samples was, however, too small to determine whether the measurement biases of the individual AMS laboratories fulfilled the WMO goal

    USGS44, a new high purity calcium carbonate reference material for δ13 C measurements

    Get PDF
    RATIONALE: The stable carbon isotopic (δ13 C) reference material (RM) LSVEC Li2 CO3 has been found to be unsuitable for δ13 C standardization work because its δ13 C value increases with exposure to atmospheric CO2 . A new CaCO3 RM, USGS44, has been prepared to alleviate this situation. METHODS: USGS44 was prepared from 8 kg of Merck high purity CaCO3 . Two sets of δ13 C values of USGS44 were determined. The first set of values was determined by on-line combustion, continuous-flow (CF) isotope-ratio mass spectrometry (IRMS) of NBS 19 CaCO3 (δ13 CVPDB = +1.95 milliurey (mUr) exactly, where mUr = 0.001 = 1 ‰), and LSVEC Li2 CO3 (δ13 CVPDB = -46.6 mUr exactly), and normalized to the two-anchor δ13 CVPDB-LSVEC isotope-delta scale. The second set of values was obtained by dual-inlet (DI) IRMS of CO2 evolved by reaction of H3 PO4 with carbonates, corrected for cross contamination, and normalized to the single anchor δ13 CVPDB scale. RESULTS: USGS44 is stable and isotopically homogeneous to within 0.02 mUr in 100-μg amounts. It has a δ13 CVPDB-LSVEC value of -42.21 ± 0.05 mUr. Single-anchor δ13 CVPDB values of -42.08 ± 0.01 and -41.99 ± 0.02 mUr were determined by DI-IRMS with corrections for cross contamination. CONCLUSIONS: The new high-purity, well homogenized calcium carbonate isotopic reference material USGS44 is stable and has a δ13 CVPDB-LSVEC value of -42.21 ± 0.05 mUr for both EA-IRMS and DI-IRMS measurements. As a carbonate relatively depleted in 13 C, it is intended for daily use as a secondary isotopic reference material to normalize stable carbon isotope-delta measurements to the δ13 CVPDB-LSVEC scale. It is useful in quantifying drift with time, determining mass-dependent isotopic fractionation (linearity correction), and adjusting isotope-ratio-scale contraction. Due to its fine grain size (smaller than 63 μm), it is not suitable as a δ18 O reference material. A δ13 CVPDB-LSVEC value of -29.99 ± 0.05 mUr was determined for NBS 22 oil

    Evaluation of a field-deployable Nafion (TM)-based air-drying system for collecting whole air samples and its application to stable isotope measurements of CO2

    Get PDF
    Atmospheric flask samples are either collected at atmospheric pressure by opening a valve of a pre-evacuated flask or pressurized with the help of a pump to a few bar above ambient pressure. Under humid conditions, there is a risk that water vapor in the sample leads to condensation on the walls of the flask, notably at higher than ambient sampling pressures. Liquid water in sample flasks is known to affect the CO2 mixing ratios and also alters the isotopic composition of oxygen (17O and 18O) in CO2 via isotopic equilibration. Hence, for accurate determination of CO2 mole fractions and its stable isotopic composition, it is vital to dry the air samples to a sufficiently low dew point before they are pressurized in flasks to avoid condensation. Moreover, the drying system itself should not influence the mixing ratio and the isotopic composition of CO2 or that of the other constituents under study. For the Airborne Stable Isotopes of Carbon from the Amazon (ASICA) project focusing on accurate measurements of CO2 and its singly substituted stable isotopologues over the Amazon, an air-drying system capable of removing water vapor from air sampled at a dew point lower than -2 °C, flow rates up to 12 L min-1 and without the need for electrical power was needed. Since to date no commercial air-drying device that meets these requirements has been available, we designed and built our own consumable-free, power-free and portable drying system based on multitube Nafion™ gas sample driers (Perma Pure, Lakewood, USA). The required dry purge air is provided by feeding the exhaust flow of the flask sampling system through a dry molecular sieve (type 3A) cartridge. In this study we describe the systematic evaluation of our Nafion™-based air sample dryer with emphasis on its performance concerning the measurements of atmospheric CO2 mole fractions and the three singly substituted isotopologues of CO2 (16O13C16O, 16O12C17O and 16O12C18O), as well as the trace gas species CH4, CO, N2O and SF6. Experimental results simulating extreme tropical conditions (saturated air at 33 °C) indicated that the response of the air dryer is almost instantaneous and that approximately 85 L of air, containing up to 4 % water vapor, can be processed staying below a -2 °C dew point temperature (at 275 kPa). We estimated that at least eight flasks can be sampled (at an overpressure of 275 kPa) with a water vapor content below -2 °C dew point temperature during a typical flight sampling up to 5 km altitude over the Amazon, whereas the remaining samples would stay well below 5 °C dew point temperature (at 275 kPa). The performance of the air dryer on measurements of CO2, CH4, CO, N2O, and SF6 and the CO2 isotopologues 16O13C16O and 16O12C18O was tested in the laboratory simulating real sampling conditions by compressing humidified air from a calibrated cylinder, after being dried by the air dryer, into sample flasks. We found that the mole fraction and the isotopic composition difference between the different test conditions (including the dryer) and the base condition (dry air, without dryer) remained well within or very close to, in the case of N2O, the World Meteorological Organization recommended compatibility goals for independent measurement programs, proving that the test condition induced no significant bias on the sample measurements
    corecore