14 research outputs found

    Parks for people : examining the creation and refurbishment of a public park

    Get PDF
    This paper takes an historical perspective to examine the social and community motivations for public parks and their funding. Public parks can be some of the most valuable green infrastructure assets; understanding why they were created and how they have developed can usefully inform current international practice. Analysis is of one the UK’s first public parks, Peel Park, Salford, Greater Manchester and draws on documentary material from the Park’s creation in the 1840s and its refurbishment in the 2010s. Common and long-lived expectations for community cohesion are found, but for contemporary management we highlight the importance of park quality and understanding public parks as part of wider equality issues. We also argue that entrepreneurial municipalism and diversified funding arrangements introduce diverse politics and interests to park provision. A lack of government funding, and thus a reliance on charitable and philanthropic sources, also potentially categorise public park provision as non-essential

    Real-world performance and accuracy of stress echocardiography: The EVAREST observational multi-centre study

    Get PDF
    Aims - Stress echocardiography is widely used to identify obstructive coronary artery disease. High accuracy is reported in expert hands but is dependent on operator training and image quality. The EVAREST study provides UK-wide data to evaluate real-world performance and accuracy of stress echocardiography. Methods and Results - Participants undergoing stress echocardiography for coronary artery disease were recruited from 31 hospitals. Participants were followed up through health records which underwent expert adjudication. Cardiac outcome was defined as anatomically or functionally-significant stenosis on angiography, revascularisation, medical management of ischaemia, acute coronary syndrome or cardiac-related death within six months. 5131 patients (55% male) participated with a median age of 65 years (IQR 57 – 74). 72.9% of studies used dobutamine and 68.5% were contrast studies. Inducible ischaemia was present in 19.3% of scans. Sensitivity and specificity for prediction of a cardiac outcome were 95.4% and 96.0%, respectively, with an accuracy of 95.9%. Sub-group analysis revealed high levels of predictive accuracy across a wide range of patient and protocol sub-groups, with the presence of a resting regional wall motion abnormalitiy significantly reducing the performance of both dobutamine (p<0.01) and exercise (p<0.05) stress echocardiography (p<0.05). Overall accuracy remained consistently high across all participating hospitals. Conclusion – Stress echocardiography has high accuracy across UK-based hospitals and thus indicates stress echocardiography is being delivered effectively in real-world practice, reinforcing its role as a first-line investigation in the assessment of patients with stable chest pain

    Left ventricular assessment with artificial intelligence increases the diagnostic accuracy of stress echocardiography

    Get PDF
    Aims: To evaluate whether left ventricular ejection fraction (LVEF) and global longitudinal strain (GLS), automatically calculated by artificial intelligence (AI), increases the diagnostic performance of stress echocardiography (SE) for coronary artery disease (CAD) detection. Methods and results SEs from 512 participants who underwent a clinically indicated SE (with or without contrast) for the evaluation of CAD from seven hospitals in the UK and US were studied. Visual wall motion scoring (WMS) was performed to identify inducible ischaemia. In addition, SE images at rest and stress underwent AI contouring for automated calculation of AI-LVEF and AI-GLS (apical two and four chamber images only) with Ultromics EchoGo Core 1.0. Receiver operator characteristic curves and multivariable risk models were used to assess accuracy for identification of participants subsequently found to have CAD on angiography. Participants with significant CAD were more likely to have abnormal WMS, AI-LVEF, and AI-GLS values at rest and stress (all P &amp;lt; 0.001). The areas under the receiver operating characteristics for WMS index, AI-LVEF, and AI-GLS at peak stress were 0.92, 0.86, and 0.82, respectively, with cut-offs of 1.12, 64%, and −17.2%, respectively. Multivariable analysis demonstrated that addition of peak AI-LVEF or peak AI-GLS to WMS significantly improved model discrimination of CAD [C-statistic (bootstrapping 2.5th, 97.5th percentile)] from 0.78 (0.69–0.87) to 0.83 (0.74–0.91) or 0.84 (0.75–0.92), respectively. Conclusion AI calculation of LVEF and GLS by contouring of contrast-enhanced and unenhanced SEs at rest and stress is feasible and independently improves the identification of obstructive CAD beyond conventional WMSI

    Real world hospital costs following stress echocardiography in the UK: a costing study from the EVAREST/BSE-NSTEP multi-centre study

    Get PDF
    Background: Stress echocardiography is widely used to detect coronary artery disease, but little evidence on downstream hospital costs in real-world practice is available. We examined how stress echocardiography accuracy and downstream hospital costs vary across NHS hospitals and identified key factors that affect costs to help inform future clinical planning and guidelines. Methods: Data on 7636 patients recruited from 31 NHS hospitals within the UK between 2014 and 2020 as part of EVAREST/BSE-NSTEP clinical study, were used. Data included all diagnostic tests, procedures, and hospital admissions for 12 months after a stress echocardiogram and were costed using the NHS national unit costs. A decision tree was built to illustrate the clinical pathway and estimate average downstream hospital costs. Multi-level regression analysis was performed to identify variation in accuracy and costs at both patient, procedural, and hospital level. Linear regression and extrapolation were used to estimate annual hospital cost-savings associated with increasing predictive accuracy at hospital and national level. Results: Stress echocardiography accuracy varied with patient, hospital and operator characteristics. Hypertension, presence of wall motion abnormalities and higher number of hospital cardiology outpatient attendances annually reduced accuracy, adjusted odds ratio of 0.78 (95% CI 0.65 to 0.93), 0.27 (95% CI 0.15 to 0.48), 0.99 (95% CI 0.98 to 0.99) respectively, whereas a prior myocardial infarction, angiotensin receptor blocker medication, and greater operator experience increased accuracy, adjusted odds ratio of 1.77 (95% CI 1.34 to 2.33), 1.64 (95% CI 1.22 to 2.22), and 1.06 (95% CI 1.02 to 1.09) respectively. Average downstream costs were £646 per patient (SD 1796) with significant variation across hospitals. The average downstream costs between the 31 hospitals varied from £384–1730 per patient. False positive and false negative tests were associated with average downstream costs of £1446 (SD £601) and £4192 (SD 3332) respectively, driven by increased non-elective hospital admissions, adjusted odds ratio 2.48 (95% CI 1.08 to 5.66), 21.06 (95% CI 10.41 to 42.59) respectively. We estimated that an increase in accuracy by 1 percentage point could save the NHS in the UK £3.2 million annually. Conclusion: This study provides real-world evidence of downstream costs associated with stress echocardiography practice in the UK and estimates how improvements in accuracy could impact healthcare expenditure in the NHS. A real-world downstream costing approach could be adopted more widely in evaluation of imaging tests and interventions to reflect actual value for money and support realistic planning

    Green belts and urban containment: the Merseyside experience

    No full text
    The green belt, without question the most well-known and influential legacy of town and country planning in the UK, continues to attract interest from a wide range of interested parties–from those eager to maintain the protection it offers to the countryside, to others more concerned at the negative impacts it is argued to have on housing supply and consequently prices. In this paper we explore how the arguments for a green belt around a particular city in the UK–Liverpool–were built up over the middle years of the twentieth century, in particular through three important (sub-)regional plans. Analysis of those plans is situated within national policy and nationwide rhetoric to illustrate how perfectly justifiable arguments about the need to limit urban sprawl “baked in” resentment and opposition to much-needed housing growth. A situation which, as the final section of the paper briefly reflects upon, not only contributed to the wide-scale construction of high-rise flats in the city from the 1950s onwards, but continues to resonate today through the objections lodged against attempts to enhance the spatial footprint of the city through development on the green belt

    Real-world performance and accuracy of stress echocardiography: the EVAREST observational multi-centre study

    No full text
    Aims Stress echocardiography is widely used to identify obstructive coronary artery disease (CAD). High accuracy is reported in expert hands but is dependent on operator training and image quality. The EVAREST study provides UK-wide data to evaluate real-world performance and accuracy of stress echocardiography. Methods and results Participants undergoing stress echocardiography for CAD were recruited from 31 hospitals. Participants were followed up through health records which underwent expert adjudication. Cardiac outcome was defined as anatomically or functionally significant stenosis on angiography, revascularization, medical management of ischaemia, acute coronary syndrome, or cardiac-related death within 6 months. A total of 5131 patients (55% male) participated with a median age of 65 years (interquartile range 57–74). 72.9% of studies used dobutamine and 68.5% were contrast studies. Inducible ischaemia was present in 19.3% of scans. Sensitivity and specificity for prediction of a cardiac outcome were 95.4% and 96.0%, respectively, with an accuracy of 95.9%. Sub-group analysis revealed high levels of predictive accuracy across a wide range of patient and protocol sub-groups, with the presence of a resting regional wall motion abnormalitiy significantly reducing the performance of both dobutamine (P < 0.01) and exercise (P < 0.05) stress echocardiography. Overall accuracy remained consistently high across all participating hospitals. Conclusion Stress echocardiography has high accuracy across UK-based hospitals and thus indicates stress echocardiography is being delivered effectively in real-world practice, reinforcing its role as a first-line investigation in the assessment of patients with stable chest pain
    corecore