195 research outputs found

    Antisoiling technology: Theories of surface soiling and performance of antisoiling surface coatings

    Get PDF
    Physical examination of surfaces undergoing natural outdoor soiling suggests that soil matter accumulates in up to three distinct layers. The first layer involves strong chemical attachment or strong chemisorption of soil matter on the primary surface. The second layer is physical, consisting of a highly organized arrangement of soil creating a gradation in surface energy from a high associated with the energetic first layer to the lowest possible state on the outer surfce of the second layer. The lowest possible energy state is dictated by the physical nature of the regional atmospheric soiling materials. These first two layers are resistant to removal by rain. The third layer constitutes a settling of loose soil matter, accumulating in dry periods and being removed during rainy periods. Theories and evidence suggest that surfaces that should be naturally resistant to the formation of the first two-resistant layers should be hard, smooth, hydrophobic, free of first-period elements, and have the lowest possible surface energy. These characteristics, evolving as requirements for low-soiling surfaces, suggest that surfaces or surface coatings should be of fluorocarbon chemistry. Evidence for the three-soil-layer concept, and data on the positive performance of candidate fluorocarbon coatings on glass and transparent plastic films after 28 months of outdoor exposure, are presented

    Predictive aging of polymers

    Get PDF
    A method of predicting aging of polymers operates by heating a polymer in the outdoors to an elevated temperature until a change of property is induced. The test is conducted at a plurality of temperatures to establish a linear Arrhenius plot which is extrapolated to predict the induction period for failure of the polymer at ambient temperature. An Outdoor Photo Thermal Aging Reactor (OPTAR) is also described including a heatable platen for receiving a sheet of polymer, means to heat the platen and switching means such as a photoelectric switch for turning off the heater during dark periods

    An advanced technology space station for the year 2025, study and concepts

    Get PDF
    A survey was made of potential space station missions that might exist in the 2020 to 2030 time period. Also, a brief study of the current state-of-the-art of the major subsystems was undertaken, and trends in technologies that could impact the subsystems were reviewed. The results of the survey and study were then used to arrive at a conceptual design of a space station for the year 2025. Factors addressed in the conceptual design included requirements for artificial gravity, synergies between subsystems, and the use of robotics. Suggestions are made relative to more in-depth studies concerning the conceptual design and alternative configurations

    Applications of ethylene vinyl acetate as an encapsulation material for terrestrial photovoltaic modules

    Get PDF
    Terrestrial photovoltaic modules must undergo substantial reductions in cost in order to become economically attractive as practical devices for large scale production of electricity. Part of the cost reductions must be realized by the encapsulation materials that are used to package, protect, and support the solar cells, electrical interconnects, and other ancillary components. As many of the encapsulation materials are polymeric, cost reductions necessitate the use of low cost polymers. The performance and status of ethylene vinyl acetate, a low cost polymer that is being investigated as an encapsulation material for terrestrial photovoltaic modules, are described

    Chemical Bonding Technology: Direct Investigation of Interfacial Bonds

    Get PDF
    This is the third Flat-Plate Solar Array (FSA) Project document reporting on chemical bonding technology for terrestrial photovoltaic (PV) modules. The impetus for this work originated in the late 1970s when PV modules employing silicone encapsulation materials were undergoing delamination during outdoor exposure. At that time, manufacturers were not employing adhesion promoters and, hence, module interfaces in common with the silicone materials were only in physical contact and therefore easily prone to separation if, for example, water were to penetrate to the interfaces. Delamination with silicone materials virtually vanished when adhesion promoters, recommended by silicone manufacturers, were used. The activities related to the direct investigation of chemically bonded interfaces are described

    Analysis of a rotating advanced-technology space station for the year 2025

    Get PDF
    An analysis is made of several aspects of an advanced-technology rotating space station configuration generated under a previous study. The analysis includes examination of several modifications of the configuration, interface with proposed launch systems, effects of low-gravity environment on human subjects, and the space station assembly sequence. Consideration was given also to some aspects of space station rotational dynamics, surface charging, and the possible application of tethers

    Some operational aspects of a rotating advanced-technology space station for the year 2025

    Get PDF
    The study of an Advanced Technology Space Station which would utilize the capabilities of subsystems projected for the time frame of the years 2000 to 2025 is discussed. The study includes tradeoffs of nuclear versus solar dynamic power systems that produce power outputs of 2.5 megawatts and analyses of the dynamics of the spacecraft of which portions are rotated for artificial gravity. The design considerations for the support of a manned Mars mission from low Earth orbit are addressed. The studies extend to on-board manufacturing, internal gas composition effects, and locomotion and material transfer under artificial gravity forces. The report concludes with an assessment of technology requirements for the Advanced Technology Space Station

    Postural stability in older adults with a distal radial fracture

    Get PDF
    BACKGROUND: The physical risk factors leading to distal radial fractures are poorly understood. The goal of this study was to compare postural stability between older adults with and without a prior distal radial fragility fracture. METHODS: This case-control evaluation was performed at a single tertiary institution. The fracture cohort comprised 23 patients treated for a low-energy distal radial fracture within 6 to 24 months prior to this study. Twenty-three age and sex-matched control participants, without a prior fragility fracture, were selected from an outpatient clinic population. All participants completed a balance assessment with a computerized balance platform device. Dynamic motion analysis (DMA) scores ranging from 0 to 1,440 points are produced, with lower scores indicating better postural stability. Participants also completed validated questionnaires for general health quality (EuroQol-5D-3L [EQ-5D-3L]) and physical activity (Physical Activity Scale for the Elderly [PASE]) and comprehensive health and demographic information including treatment for compromised balance or osteoporosis. Statistical analysis compared data between cases and controls using either the Student t test or the Mann-Whitney U test. RESULTS: There were no significant differences (p > 0.05) in age, sex, body mass index, physical activity score, or EQ-5D-3L general health visual analog scale score between participants with or without prior distal radial fracture. The fracture cohort demonstrated poorer balance, with higher DMA scores at 933 points compared with 790 points for the control cohort (p = 0.008). Nineteen patients (83%) in the fracture cohort reported having dual x-ray absorptiometry (DXA) scans within 5 years prior to this study, but only 2 patients (9%) had ever been referred for balance training with physical therapy. CONCLUSIONS: Older adults who sustain low-energy distal radial fractures demonstrate impaired postural stability compared with individuals of a similar age who have not sustained such fractures. Following a distal radial fracture, these patients may benefit from interventions to improve postural stability. LEVEL OF EVIDENCE: Prognostic Level III. See Instructions for Authors for a complete description of levels of evidence

    The osteoporosis care gap in Canada

    Get PDF
    BACKGROUND: The presence of a fragility fracture is a major risk factor for osteoporosis, and should be an indicator for osteoporosis diagnosis and therapy. However, the extent to which patients who fracture are assessed and treated for osteoporosis is not clear. METHODS: We performed a review of the literature to identify the practice patterns in the diagnosis and treatment of osteoporosis in adults over the age of 40 who experience a fragility fracture in Canada. Searches were performed in MEDLINE (1966 to January 2, 2003) and CINAHL (1982 to February 1, 2003) databases. RESULTS: There is evidence of a care gap between the occurrence of a fragility fracture and the diagnosis and treatment of osteoporosis in Canada. The proportion of individuals with a fragility fracture who received an osteoporosis diagnostic test or physician diagnosis ranged from 1.7% to 50%. Therapies such as hormone replacement therapy, bisphosphonates or calcitonin were being prescribed to 5.2% to 37.5% of patients. Calcium and vitamin D supplement intake was variable, and ranged between 2.8% to 61.6% of patients. CONCLUSION: Many Canadians who experience fragility fracture are not receiving osteoporosis management for the prevention of future fractures
    corecore